Furuno WV-100 Bedienungsanleitung

www.furuno.com
A
ll brand and product names are trademarks, registered trademarks or service marks of their respective holders.
Installation Manual
Wave Analyzer
WV-100/WV-100ST
IMPORTANT NOTICES.................................................................................................... i
SYSTEM CONFIGURATION ........................................................................................... ii
1. PREPARATION .......................................................................................................... 1
1.1 Components..........................................................................................................................1
1.2 How to Setup the PC ............................................................................................................2
1.3 How to Install the Software ...................................................................................................3
1.4 How to Connect the LAN Cable............................................................................................4
1.5 How to Start and Quit the Software ......................................................................................5
1.6 Initial Settings........................................................................................................................6
2. DISPLAY SCREEN, OPERATIONAL OVERVIEW .................................................. 10


i
IMPORTANT NOTICES
• This manual has been authored with simplified grammar, to meet the needs of international us-
ers.
• The operator of this software must read and follow the descriptions in this manual.
Wrong operation or maintenance can cancel the warranty or cause injury.
• Do not copy any part of this manual without written permission from FURUNO.
• If this manual is lost or worn, contact your dealer about replacement.
• The contents of this manual and software specifications can change without notice.
• The example screens (or illustrations) shown in this manual can be different from the screens
you see on your display. The screens you see depend on your system configuration and equip-
ment settings.
• Save this manual for future reference.
• Any modification of the equipment (including software) by persons not authorized by FURUNO
will cancel the warranty.
• The following concern acts as our importer in Europe, as defined in DECISION No 768/2008/
EC.
- Name: FURUNO EUROPE B.V.
- Address: Siriusstraat 86, 5015 BT, Tilburg, The Netherlands
• The following concern acts as our importer in UK, as defined in SI 2016/1025 as amended SI
2019/470.
- Name: FURUNO (UK) LTD.
- Address: West Building Penner Road Havant Hampshire PO9 1QY, U.K.
• Microsoft and Windows are registered trademarks or trademarks of the Microsoft Corporation
of the USA and other countries.
• Intel and Core are registered trademarks or trademarks of the Intel Corporation of the USA and
other countries.
• GeForce is registered trademark or trademark of the NVIDIA Corporation of the USA and other
countries.
• All brand and product names are trademarks, registered trademarks or service marks of their
respective holders.

ii
SYSTEM CONFIGURATION
LAN1
Antenna Unit Gyrocompass,
GPS Navigator Wind Sensor*1
Intelligent HUB
HUB-3000
Processor Unit
Control Unit Monitor Unit
CHART RADAR FAR-3xxx series
or
MARINE RADAR FAR-2xx8 series
PC*2 for wave analysis
(Local supply, wave analyzer
software installed in PC)
*1: For wave analysis, required wind
direction/speed data from the
wind sensor. The data should be
directly input to the radar, or
available on the network via
sensor adapter.
*2: The PC should be connected to the
LAN1 port during wave analysis.
Firewall
Wave analysis PC

1
1. PREPARATION
1.1 Components
Standard Supply
The wave analyzer WV-100/WV-100ST contains the following items.
Wave Analyzer WV-100 (Code no.: 001-562-500)
Wave Analyzer WV-100ST (Code no.: 001-562-510)
Folder structure of the CD-ROM
PC requirements
*: Languages other than Japanese and English are not covered under the warranty.
Name Type Code No. Qty Remarks
CD-ROM WV-100/ST 001-564-430 1 Wave analysis software in-
cluding Operator’s Manual
USB Protec-
tion Key
WV-100 001-564-410 1
WV-100ST 001-564-420
Installation
Manual
IMC-36181-x 000-196-579-1x 1 Both English and Japanese
(x: Version number)
Folder File Remarks
WaveAnalyzer_
setup
vcredist_
x64
vcredist_x64.exe Redistribution package of visu-
alstudio
– setup.exe Install additional components
(Redistribution package of visu-
alstudio)
– WaveAnalyzer
Installer.msi
Install file of wave radar software
including Operator’s Manual
OSS freetype-master.zip,
ftgl-2.1.3-rc5.tar.gz,
NupenGL-master.zip,
PDFsharp-MigraDoc.
1.50.5147.nupkg
OSS files
OS Microsoft®Windows®10/11 Pro / Home (English or Japanese*)
CPU Intel®Core™i5 or better
GPU NVIDIA GeForce®GTX1050 or better
(CUDA core: Min. 384, Memory: Min. 2 GB)
Memory Min. 4 GB
SSD/HDD Min. 128 GB
Interface Ethernet 100 Base-T, USB (type A) ×2 (One is for USB protection
key, the other is for USB serial conversion adapter.), Video output
(HDMI, DVI, and so on)
Resolution FullHD

1. PREPARATION
2
1.2 How to Setup the PC
Note: The item names may be different depending on your operating system.
1. Power the PC.
2. Set the IP address and subnet mask in [Network and Internet] – [Network and
Sharing Center] – [Change adapter settings] – [Ethernet] – [Properties] – [Internet
Protocol Version 4 (TCP/IPv4) Properties].
• IP address: 192.168.31.226
• Subnet mask: 255.255.255.0
3. Set the following items in [Power Options].
• [System Settings] – [When I press the power button]: Select [Do nothing].
• [System Settings] – [When I close the lid] or [When I press the sleep button]:
Select [Do nothing].
• [System Settings] – [Shutdown settings] – [Turn on fast startup]: Uncheck the
box.
• [Create a power plan]: Select [Balanced] or [High performance].
• [Edit Plan Settings] – [Turn off the display]: Select [Never] or an arbitrary option.
• [Edit Plan Settings] – [Put the computer to sleep]: Select [Never].
Note: When there is no menu item listed above, set your PC not to sleep while
running this software.
4. Set the following items in [Display].
• [Scale and layout] – [Change the size of text, apps, and other items]: Select
[100%].
• [Scale and layout] – [Resolution]: Select [1920 ×1080].
Firewall Settings
As part of the software installation process (see section 1.3), two shortcuts are created
on your desktop for switching firewall settings.
• [Enable Firewall for Wave Analyzer]: firewall settings are adjusted and optimized
for the analysis software.
• [ Disable Firewall for Wave Analyzer]: optimizations are removed and previous set-
tings are restored.
Depending on your PC settings, the [User Account Control] dialog may appear when
you click either of the shortcuts.If the [User Account Control] dialog appears, click
[Yes].

1. PREPARATION
3
1.3 How to Install the Software
Note: Install the software with administration rights.
1. Turn the PC on.
2. Set the supplied CD-ROM in the CD drive.
3. Double-click [WaveAnalyzer_setup].
4. Double-click [WaveAnalyzerInstaller.msi].
5. Click [Next].
6. Click [Next]. To change the installation folder, click [Browse] and select the folder
before clicking [Next].
x.x

1. PREPARATION
4
7. Click [Next] to start the installation.
Note: If the dialog box [UserAccountControlSettings] appears, click [Yes] to start
the installation.
When the installation is completed, the dialog box shown below appears.
8. Click [Close] to finish. The shortcut icons for the manual and related software are
created on your desktop.
Referring to section 1.2, setup the network and firewall settings for the connected ra-
dar to match the PC firewall settings.
1.4 How to Connect the LAN Cable
Connect the PC to the LAN1 port on the processor unit of FAR-3xxx or FAR-2xx8 se-
ries via the intelligent HUB (HUB-3000).
Software for
wave analyzer
Operator’s
manual
Firewall-related software

1. PREPARATION
5
1.5 How to Start and Quit the Software
1. Power the FAR-3xxx or FAR-2xx8 series.
Note: For the FAR-2xx8 series, output data to the PC is set to on: [ECHO] - [OUT-
PUT TO WAVE PC] - [ON] (default [OFF]). In addition, both the FAR-3xxx and
FAR-2xx8 series need to output the radar echo to the PC: [ECHO] - [WAVE
MODE] - [ON] (default [OFF]).
2. Insert the USB dongle into a USB port on the PC. The LED in the dongle lights red.
Note: The USB dongle is required to use this software. Take care not to lose it.
3. Power the PC. The software automatically starts up and the following screen ap-
pears.
Note 1: If the following message appears, click [OK] to delete the message and
then re-insert the USB dongle.
Note 2: If the message for software error appears, click [OK] to delete the mes-
sage and then re-insert the USB dongle. Double-click the shortcut icon for the
software on the desktop to start up the software.

1. PREPARATION
6
Note 3: If the USB dongle is removed after starting the software, the following
message appears.
Click [Cancel] to quit the software. Insert the USB dongle and double-click the
shortcut icon for the software on the desktop to restart the software.
Note 4: If the firewall is not configured, the error message to the below-left ap-
pears. Click [OK], the message to the below-right then appears.
Click [OK] to delete the message, then open the [Enable Firewall for Wave Ana-
lyzer] shortcut on your desktop. If the [User Account Control] dialog appears, click
[Yes].
4. To quit the software, click the close button (x) at the upper right corner of the
screen. The confirmation message "Are you sure you want to exit?" appears.
5. Click [YES] to quit the software.
1.6 Initial Settings
1. Click [MENU] at the upper right of the screen to
open the menu.
2. Click [3. INITIAL SETTINGS] to open the pass-
word entry screen.
Retry Cancel
1. SYSTEM MONITOR
2. ALERT STATUS
3. INITIAL SETTINGS
4. SEA CONDITION REPORT
Enter the password
Cancel OK
Andere Handbücher für WV-100
1
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Furuno Messgerät Handbücher






















