Glide SW-400 Bedienungsanleitung

I N T E R
REMOTE CONTROLLED
SWING GATE OPENER
SW-400, UG-300, SWR 400
OWNERS MANUAL & SERVICE BOOK

Dear Customer,
We wish to congratulate you for choosing
INTERGLIDE AUTOCONTRLS
system, leading supplier of various type automatic opening systems for
Swing Gates, sliding Gates, Rolling Shutters, Garage shutters, Boom Barriers,
Sliding Glass Doors etc, which are developed in India.
Hence, we assure you trouble free operation and committed service at all
time to come.
To ensure a long trouble-free operation, give proper care and maintenance
as described in this manual.
We wish you the best out of this system.
INTERGLIDE AUTOCONTROLS
All information in this manual is based on the latest product information available at the time of publication. We are committed
to make changes and improvements at any time.

INSTRUCTIONS
SITE INSPECTION
Before begin to install the Automatic System, please check following.
1. Structure of the Gate Poll should be sufficiently strong to support the
mechanism. The hinges must function efficiently and there must be no friction
between moving parts and fixed parts, other than usual.
2. Check the floor level and make sure that the gate should not rub on ground,
during opening / closing.
We offer 3 types of operators for Swing Gates.
1. Swing Gate Opener - SW 400
2. Under Ground Opener - UGS 300
3. Roller Swing gate Opener- SWR- 500
STANRARDS PACKINGS
Arm Gate Motor - 2 Nos
Mounting Brackets - 2 Sets
Remote transmitter - 2 Nos
Close Hit bush - 1 No
Control Box with control Board - 1 No
Release Keys - 2 Nos
OPTIONAL ITEMS:
Photocell
Flashing Light
Battery Backup
Electric Lock

Arm Gate Motor: Motor with gear assembly to open / close the gate.
Control Box- This consists of Microprocessor based control circuits to supply drive
power to the motor. It also contains back up Battery and Radio Frequency Receiver.
Remote Transmitter: This is hand held remote switch to signal open/close
operation. Range of the transmitter without any obstruction is approximately
100Mtrs.
Release Keys: This key is used to release the motor mechanism to the gate in case
of any malfunction of the gate or during power failure.
Electro Magnetic Lock (EM Lock): This lock is attached to Gate with MOTOR 1.
While closing this lock gets locked to the slot and while opening, it gets released
itself and open. This acts like a tower bolt for added safety. This lock can be
disabled by using the release key provided.
Motor Layout
1. Check the measurement ‘C’. If C is more than 110MM, it is ideal to use Roller
Swing/ UG series.

2. Lubricate the Gate Hinge and check the load on the gate leaf with a spring
balance at a point 1 Mt from the hinge. If the load is more than 5 Kg (generally
for Cast Iron Gates) it is ideal to use either SW 800, UG 800 or WMS 800. If less
than 5 Kg SW 300, UG 300 or WMS 300 can be used.
3. If the visibility of the OPENER matters especially when the swing gate open
outwards, it is preferred to use UNDERGROUND Operator UG 300 /800.
4. There are cases where one gate leaf can open only 90 degree, and the other
more than 90 degree, it is advisable to use Underground / Wall mounted system.
Opening angle till 180 degree is possible.
5 Places where KSEB power is not available or not easy to access, there is
provision for SOLAR POWERED SYSTEM.
SPECIFICATIONS
SW300
UG 300
SW500
SWR
500
Input
Power
220VAC
220VAC
220VAC
220VAC
Battery
Backup -
option
12V/7Ah-2
12V/7Ah-2
12V/7Ah-2
12V /7Ah-2 Nos
DC Motor
24VDC/80W
24VDC/50
W
24VDC/100W
24VDC/50W
Operating
Time
10 to 12 Sec
10 to 12
Sec
10 to 12 Sec
10 to 12 Sec
Operating
speed
Fast / Slow
Fast / Slow
Fast / Slow
Fast /Slow
Allowed
Gate size
300Kg/3Mtr
250Kg/3Mt
600 Kg/2 Mt
500Kg/3 Mt
Control
Drive
Microprocesso
r PWM based
Microproce
ssor PWM
based
Microprocess
or PWM
based
Microprocessor
PWM based
Radio
Transmitter
2Ch/433 MHz
yes
yes
yes
EM Lock
Yes
Yes
Yes
Inbuilt
Audio/Vide
o indication
optional
opt
opt
Photocell
with auto
close
optional
opt
opt
opt
Protection
Class
IP54
IP 54
IP 65
IP54

SWING GATE OPENER - SW 300
INSTALLATION- Auto Gate OPERATION SETTINGS- Auto Gate
STOP Motor
immediately.
Ensure that the gate moves
in full extent. Weld the tip
clamp strong.
Install the other motor.
.
Mount Base Bracket with Anchor
Bolt & Lead Plate, corresponds to a
horizontal section of gate, as per the
measurements
Close the gate. Release Motor Gear.
Take water level from this Lead plate to
the gate and mark.. Screw the Motor
Arm to the LEAD Plate. Extend the
Motor Arm fully out. Rotate Arm
Extension ONE Turn clockwise. Spot
weld the Tip Clamp to the gate.
Connect both motors
electrically, to the
control board.
Ensure that the Pillar is strong
enough to mount the Motor Bracket.
Reverse that
Motor
connections, in the
control Board
Both Gate
Opens.
Any Gate
Closes
START - 2S
Keep the gate half
way open & engage
gear.
Do appropriate
Preset settings.
eeeEnsure
ff4fssssssettingsset
tings.Switch 8
Do Electrical
Connections
Ensure that both
gates start and run
in full speed and go
to slow speed just
before stopping.

Prepartion for Installation
In order to have a smooth installation, please make sure that
1. The gate work manually, without any obstacle
2. Hinges are stabe and in good condition.
Fix the rear support Clamp on the gate post. If necessary, please adjust the support
length.
Selection of Opening Angle for SW 300
Opening
Angle
A in MM
Bin MM
C in MM
90 degrees
145
145
130
Degrees
132
132
Eg: INSTALLATION DIAGRAM- Open angle –90 degrees

If the size on the diagram A is changed, then the opening angle will be changed (90
–110 degrees)
Please change the size according to following rule.
1. 132<A<145,132<b<145 mm
2. If the opening angle is more than 90 degrees, then A+B<C
3. The smaller value A and B, the faster the gate works.
If the size of the gate post or hinges not the same as A, please dig according
to following diagram.
Installation procedure:
If the Pillar is Iron, weld supporting clamps. If Concrete use Anchor Bolts.
1. Release the GEAR MOTOR ARM. CLOSE both gates.
2. Extend the Lever Arm fully outwards, by rotating the Arm Extension.
3. Rotate the Arm Extension one turn clockwise.
4. Mount the Base bracket to the pilar, corresponds to horizontal section of the gate.
using water level. Fix with anchor bolt. Attach Tail Plate with 2 bolts.
5. Screw the Motor Arm to this Tail Plate. Then spot weld the END Clamp to the
gate. See that the Motor arm is horizontal.
5. Ensure the gate can be opened and closed fully.
6. Weld the End Clamp strong. And install second motor like this.
7. CLOSE both gates.

MANUAL RELEASE
If Power fails or on motor Stoppage, please open the waterproof cover on the Motor
Arms and insert the release key and turn quarter turn clockwise. This operation
releases the gear from the motor and the gate can be manually moved.
Do this for the other gate also.
To LOCK, insert the key and turn quarter turn anticlockwise.

Installation of EM Lock.
EM Lock is generally fixed to the Gate Leaf, which needs to travel more than other.
If same, it can be fixed to the gate near control box, so as to reduce wiring. Motor in
the Gate Leaf with lock is termed as M1, and other M2.
Close the gate properly and fix the LOCK BASE to the ground so that both leaves
are blocked in the upper rubber part of the base. Fix it firmly to ground.
Lock is screwed to a base plate, which is to be welded to the gate tip. Unlock EM
Lock and place it in the tip ( Fig ), so that the lock lever just moves above the base.
Bottom. It should locked into the base while closing and gets released while
opening.
Manual release system.
Connections:
Give connection to Motor1, Motor 2 and EM Lock as shown.
Connect the Battery terminals (optional) and Power the system.
Connect IR Photocell & Flash (optional)
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis