Haglof Digitech Bedienungsanleitung

MANTAX
Digitech®
V1.6 ENGLISH USER’S GUIDE

Digitech ENU rev. Feb 2011
©Hagl f Sweden®AB Mantax Digitech - 2 -
Contents
Hagl f Sweden® ...................................................................................................................................................... 5
Mantax Digitech® .................................................................................................................................................... 6
Assemble the caliper jaws ....................................................................................................................................... 7
Adjust the handle ............................................................................................................................................... 8
Jaw angle ............................................................................................................................................................ 8
MENU SELECTIONS .................................................................................................................................................. 9
Battery .............................................................................................................................................................. 10
LOCAL ................................................................................................................................................................ 10
1-key registration (1But) .............................................................................................................................. 10
3-key registration ......................................................................................................................................... 10
Double scale function ....................................................................................................................................... 10
1-key registration (1But) .............................................................................................................................. 10
3-key registration ......................................................................................................................................... 11
Delete latest registration .................................................................................................................................. 11
Reading heights from Vertex and Vertex Laser Height Measurers................................................................... 11
LINE ................................................................................................................................................................... 12
CLR .................................................................................................................................................................... 13
INSP ................................................................................................................................................................... 13
COPY ................................................................................................................................................................. 13

Digitech ENU rev. Feb 2011
©Hagl f Sweden®AB Mantax Digitech - 3 -
PC ...................................................................................................................................................................... 13
DigiCom V1.0 ......................................................................................................................................................... 14
Code .................................................................................................................................................................. 14
Name of tree species ........................................................................................................................................ 15
Edit Data ........................................................................................................................................................... 15
Delete 0-diameters ........................................................................................................................................... 15
Two 0-diameters=New plot .............................................................................................................................. 15
Three 0-diameters=New List, Stand ................................................................................................................. 15
Export data ....................................................................................................................................................... 16
Identities ........................................................................................................................................................... 16
Radius ............................................................................................................................................................... 16
Result Example Standtable ............................................................................................................................... 17
Explanations ................................................................................................................................................. 17
Example tab separated Excel txt file ................................................................................................................. 18
Data file from the caliper .................................................................................................................................. 19
Line ................................................................................................................................................................... 19
PRINT ................................................................................................................................................................ 20
RAND................................................................................................................................................................. 20
SET .................................................................................................................................................................... 21
Radio ..................................................................................................................................................................... 22

Digitech ENU rev. Feb 2011
©Hagl f Sweden®AB Mantax Digitech - 4 -
Technical specification .......................................................................................................................................... 23
Accessories ....................................................................................................................................................... 23
IR4................................................................................................................................................................. 23
IR6................................................................................................................................................................. 23
DigiRadio V1.6 .............................................................................................................................................. 23
DigiAntenn .................................................................................................................................................... 23
Declaration of conformity ..................................................................................................................................... 24
Warranty and Service Information ................................................................................................................... 24
SOFTWARE ........................................................................................................................................................ 24

Digitech ENU rev. Feb 2011
©Hagl f Sweden®AB Mantax Digitech - 5 -
HAGLÖF SWEDEN®
HAGLÖF SWEDEN AB IS A FAMILY OWNED COMPANY WITH A LONG TRADITION OF DEVELOPING AND
PRODUCING INSTRUMENTS FOR PROFESSIONAL FOREST MEASURING WORK. TODAY, HAGLÖF SWEDEN
MANUFACTURE AND SELL THE MOST COMPLETE PRODUCT RANGE FOR CRUISING AND INVENTORY WORK.
A profound know-how in workshop production technique has grown to encompass our state-of-the-art
manufacturing of electronic instruments and field software.
There are over 200 companies representing the Hagl f Sweden brand name around the world. Being a
manufacturer with self-owned and -run production facilities, the entire production process is under our
control. This ensures availability and reliable deliveries for you, as well as prompt service and support when
you need it, no matter where in the world you are located.
Every operator of a Hagl f Sweden product is a member of our innovation team. We mark our resources for
product development and maintain the flexibility of a small organization.
Many Hagl f Sweden instruments are used also outside the forestry industry, such as in building dimensions
and utility industry, for road construction, in police work, gardening, power line survey, archaeology, geology
and for wildlife management.
Hagl f Sweden AB, Box 28, SE-882 21 Långsele, Sweden.
Phone: +46 620 255 80. Fax: +46 620 205 81. E-mail: info@haglofsweden.com
www.haglofsweden.com

Digitech ENU rev. Feb 2011
©Hagl f Sweden®AB Mantax Digitech - 6 -
MANTAX DIGITECH®
The Mantax Digitech® is a light weight, easy learn-easy use digital computer caliper, designed to endure any
type of climate and daily use in a tough environment. The Digitech® consumes little battery and can
communicate with radio signals with handheld computer and other devices. Several Digitech units can operate
on an area, sending online individually separated measuring results to one handheld unit, adding value and
increasing efficiency to investments and equipment.
The Digitech caliper is available in two configurations, the Digitech® Digicruise for inventory tasks (described
herein), and the Digitech® Digilog, for log measuring, with 2000 registers possible and different variables (see
www.haglofsweden.com for details on the Digilog model). Diameters and up to 8 different tree species can be
captured and stored in the internal memory if not transferred online with radio signals or infrared light (IR).
The Mantax Digitech® is equipped with an IR receiver for direct communication with the Hagl f Sweden®
Vertex and Vertex Laser height measurers for receipt of height results.
The Digitech caliper is manufactured in three different lengths and several graduation options. For trees that
are larger than the physical scale length, the Digitech can operate with a “double scale” function, enabling the
user to register trees with large diameters. Digitech has with a built in generator for random pick of sample
trees while cruising.
The Mantax Digitech® has jaws that can be removed and exchanged with red laser pointer Gator Eyes jaws. The
red laser pointers are useful for operation in obscure surroundings and allows for diameter measuring and
measuring of branches at a distance. See www.haglofsweden.com for details on the best Gator Eyes solution
for your Hagl f caliper.
The Mantax Digitech® is operated through a menu based system. The keys L for left arrow key and R for right
arrow key, are used to choose desired function. The E-key - Enter is used to activate the function you have
chosen to work with. E is also used to turn on the Digitech caliper. To turn off, simply press both arrow keys
simultaneously (ESC) when caliper is set in main menu. ESC is also used to step out of a current menu.
Enter
ESC
Left arrow key
Right arrow
key
Battery lid IR sender/transmitter

Digitech ENU rev. Feb 2011
©Hagl f Sweden®AB Mantax Digitech - 7 -
ASSEMBLE THE CALIPER JAWS
Assemble the caliper jaws using the enclosed Allen key (wrench) and the screws with washers.
Tighten the screws using the Allen key.
Make sure the jaws are correctly assembled and guided
into the material marks on your caliper.
Mount the jaw lids
4X
4X 1X
2X
4X

Digitech ENU rev. Feb 2011
©Hagl f Sweden®AB Mantax Digitech - 8 -
ADJUST THE HANDLE
In the back part of the caliper handle you will find a compartment containing a small Allen key. Use the Allen
key to adjust the sliders and jaw angle for perfect run and alignment.
JAW ANGLE
Adjust screw 1 until the handle runs smoothly. Adjust screws 2 and 3 for the jaws to be aligned (parallel).
Tighten screws 4, 5 and 6 for the handle to run smoothly.
Screw 1
Screw 2
Screw 3
Mantax DigiTech
Screw 4,5
Screw 6
Allen key

Digitech ENU rev. Feb 2011
©Hagl f Sweden®AB Mantax Digitech - 9 -
MENU SELECTIONS
Measured
trees s
ent with
IR- or radio-
signals
Measured
trees are
stored in the
internal
memory
Delete trees
and memory
Show
(Inspect)
measured
trees
Transfer
measured
trees to PC
with IR or
Radio
Set random
generator for
sample tree
signal
Set 1-key or 3-
key function
when
measuring
and use of IR-
or Radio-
transmission.
LINE
LOCAL
PC
INSP
CLR
SET
RAND
OFF
COPY
Transfer
measured
trees to
Handheld
with IR or
Radio
Send stand
table to HP
Printer 2cm
/2Inch classes
or by Radio to
PC
PRNT

Digitech ENU rev. Feb 2011
©Hagl f Sweden®AB Mantax Digitech - 10 -
BATTERY
The caliper will alert the user when the battery needs to be changed by showing ‘Bat0’ in the display.
Collected data will remain in the memory also when changing the battery. The memory is of a non-volatile type
and does not need any backup battery. When changing battery, the version number of your caliper firmware is
shown in the display. Depending on number of previous registers, you may have to wait up to 6 seconds before
you can start working with the caliper after replacing the battery.
LOCAL
Measured trees are stored in the internal memory in the Local menu.
The number of captured measurements is featured in the display for a short while. Registration of tree species
and diameters can be made in two different ways, and your choice is made under SET in the menu. When
delivered, the Digitech caliper is set in 3-key registration mode.
1-KEY REGISTRATION (1BUT)
Press the caliper jaws around the object to measure a diameter. Select species by pressing the number as
stated below with the E-key.
1 short press for tree species 1
2 short presses for species 2
3 short presses for species 3
4 short presses for species 4
5 short presses for species 5 (or 1 fast +1 long press)
2 short presses +1 long press for species 6
3 short presses +1 long press for species 7
4 short presses +1long press for species 8
3-KEY REGISTRATION
Pick species 1..8 with the arrow keys L or R. Press the jaws around the object to
measure and press E.
Tree species’d’ offer to feature the diameter in the display without registering
any value (see double scale function next side).
DOUBLE SCALE FUNCTION
1-KEY REGISTRATION (1BUT)
If pressing E for a short while, the current diameter will be shown in the display but no registration will be
stored. Keep pressing the E key and move the caliper jaws to zero position (0) when you temporarily wish to
V 1.6
1034
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Haglof Messgerät Handbücher

Haglof
Haglof Vertex 5 Bedienungsanleitung

Haglof
Haglof Vertex Laser II VL402 Bedienungsanleitung

Haglof
Haglof Vertex III V1.5 Bedienungsanleitung

Haglof
Haglof Mantax Digitech II Bedienungsanleitung

Haglof
Haglof DME Bedienungsanleitung

Haglof
Haglof MD II Bedienungsanleitung

Haglof
Haglof Vertex Laser Geo Bedienungsanleitung

Haglof
Haglof Postax Bedienungsanleitung

Haglof
Haglof DP II Bedienungsanleitung

Haglof
Haglof Vertex 5 Bedienungsanleitung