HP HP 7500 NetStream Bedienungsanleitung

Manual Version: 6P103-20130125 BOM:
3123A0F9
Part number: 5998-2243
i
HP 7500 NetStream Monitoring Module
1 Appearance
The silkscreen LSQ1NSMSC0 is printed at the upper right corner of the front panel, and it identifies the
module.
Figure 1 Appearance of the LSQ1NSMSC0
2 Specifications
The LSQ1NSMSC0 module provides one console port, one CF card slot, two USB interfaces, two
10/100/1000BASE-T management Ethernet copper interfaces, and two management Gigabit combo
interfaces.
Figure 2 Front panel of the LSQ1NSMSC0
(1) CF card eject button (2)
CF card
slot
(CF CARD)
(3)
CF LED (CFS)
(4) Console port (CONSOLE) (5)
USB interface
1
(reserved)
(6)
USB interface 2 (reserved)
(7) Management Ethernet interface
1 (10/100/1000BASE-T)
(8) Management Ethernet interface
2
(10/100/1000BASE-T)
(9) Management Ethernet interface
1
LED
(LINK)
(10) Management Ethernet
interface 1 LED (
A
CT)
(11) Management Ethernet
interface
2
LED
(LINK)
(12) Management Ethernet
interface 2 LED (
A
CT)
(13) Management interface 3
(Electrical port of combo interface
10/100/1000BASE-T)
(14) Management interface 4
(Electrical port of combo interface
10/100/1000BASE-T)
(15) Management interface 3
(Optical port of combo interface
1000BASE-X)

Manual Version: 6P103-20130125 BOM:
3123A0F9
Part number: 5998-2243
ii
(16) Management interface 4
(Optical port of combo interface
1000BASE-X)
(17) Management interface 3 LED
(LINK)
(18) Management interface 3 LED
(ACT)
(19) Management interface 4 LED
(LINK)
(20) Management interface 4 LED
(
A
CT)
(21) Ejector lever
(22) Captive screw
Table 1 Description of the LEDs on the LSQ1NSMSC0
Silkscreen Color Status
Descri
p
tion
CFS Green
Off No CF card is present or the CF card is not
recognizable.
On A CF card is in position and has passed the
power-on self test.
Blinking The system is accessing the CF card. In this state, do
not remove the CF card.
LINK Green
Off No link is present.
On A link is present.
ACT Yellow
Off No data is being sent and received.
Blinking Data is being sent and received.
Table 2 LSQ1NSMSC0 specifications
Item S
p
ecification
Interface
One console port
Two USB interfaces (reserved)
Two 10/100/1000BASE-T management Ethernet electrical interfaces
Two Gigabit combo interfaces, supporting flexible switching between optical and
electric interfaces. Only one type of interface(s), optical or electrical, can work at a
time. Supported interface types are as follows:
•10/100/1000BASE-T electrical interface
•1000BASE-X SFP optical interface
Interface transmission
speed
•Console port—9600 bps to 115200 bps (default: 9600 bps)
•10/100/1000BASE-T electrical interface—10/100/1000 Mbps, half/full duplex
•1000BASE-X SFP optical interface—1000 Mbps, full duplex
Connector RJ-45 (for electrical interface) or SFP/LC (for optical interface)
Cable and maximum
transmission distance
•Console port—Asynchronous serial cable with maximum transmission distance of
15 m (49.21 ft)
•10/100/1000BASE-T electrical interface—Category 5 or above UTP with
maximum transmission distance of 100 m (328.08 ft)
•1000BASE-X SFP optical interface—For more information, see Table 3
CF card and slot One CF card slot, 256 MB by default for the external CF card
256 MB, 512 MB, or 1 GB for an optional external CF card
Applied to HP 7500 series switches

Manual Version: 6P103-20130125 BOM:
3123A0F9
Part number: 5998-2243
iii
Table 3 1000BASE-X SFP interface specifications
Item S
p
ecification
Connector SFP/LC
Interface standards 802.3, 802.3u, and 802.3ab
Optical
transmit
power
Type
Short-haul
multi-mode
(850 nm)
Optical
interface
module
Mid-haul
single-mode
(1310 nm)
Optical
interface
module
Long-haul
(1310 nm)
Optical
interface
module
Long-haul
(1550 nm)
Optical
interface
module
Extra-long-ha
ul (1550 nm)
Optical
interface
module
Min –9.5dBm –9dBm –2dBm –4dBm –4dBm
Max 0dBm –3dBm 5dBm 1dBm 2dBm
Reception sensitivity –17dBm –20dBm –23dBm –21dBm –22dBm
Central wavelength 850nm 1310nm 1310nm 1550nm 1550nm
Fiber type 62.5/125μm
MM fiber
9/125μm SM
fiber
9/125μm SM
fiber
9/125μm
SM fiber
9/125μm SM
fiber
Max transmission
distance
0.55 km (0.34
miles)
10 km (6.21
miles)
40 km (24.86
miles)
40 km
(24.86 miles)
70 km (43.50
miles)
3 Installing and removing the LSQ1NSMSC0
W
ARNING!
•Wear an ESD-preventive wrist strap and ESD-preventive gloves before installing or removing the
module, and make sure that the ESD-preventive wrist strap is properly grounded.
•Avoid touching any components on the PCB and hold the PCB by its edge when installing and removin
g
the module.
NOTE:
The LSQ1NSMSC0 is hot swappable. That is, you can remove the module from a switch when the switch
is powered on.
3.1 Installing the LSQ1NSMSC0
1. Locate the slot where you will install the LSQ1NSMSC0, and remove the blank panel from the
position. This manual describes installing the LSQ1NSMSC0 to slot 2.
2. Push the module (with the components facing on) into the slot along the guide rails until the
positioning hole of the module is seated onto the positioning pin on the backplane. Push the ejector
levers inward to lock the module in place.
3. Fasten the captive screws on the module with a Philips screwdriver.

Manual Version: 6P103-20130125 BOM:
3123A0F9
Part number: 5998-2243
iv
Figure 3 Insert the LSQ1NSMSC0
(1) Push the module into the slot along the guide rails until the positioning hole of the module is seated onto the
positionin
g
pin on the backplane.
(2) Push the ejector levers inward to lock the module
in place.
3.2 Removing the LSQ1NSMSC0
1. Loosen the captive screws on the module with a Philips screwdriver until all spring pressure is
released.
2. Hold the ejector levers of the module and push them outward. Gently pull the module out of the slot
along the guide rails.
3. Put the removed module on an antistatic workbench with the PCB side facing upward or place it
in an antistatic bag. If you do not install a new LSQ1NSMSC0 in the slot, install a blank panel to
prevent dust from entering the chassis and ensure normal ventilation in the switch.
4 Logging in to the LSQ1NSMSC0
Before logging in to the LSQ1NSMSC0, configure the AUX user interface of the module.

Manual Version: 6P103-20130125 BOM:
3123A0F9
Part number: 5998-2243
v
Table 4 Configure the AUX user interface of the LSQ1NSMSC0
Commands Descri
p
tion
system-view Available in user view.
user-interface aux first-number [ last-number ] Enter one or more AUX user interface views
authentication-mode none
Specify the none authentication mode
By default, password authentication is performed for users
that log in through the AUX user interface.
user privilege level level
Configure the user privilege level for login users
By default, the default command level is 0 for the AUX user
interface. HP recommends you to set the level to 3.
After configuring the AUX user interface, use the oap connect command to log in to the module from the
switch to enter the command line interface (CLI) of the module and manage the module. To return to the
CLI of the switch, press Ctrl+K.
Table 5 Redirect from the switch to the LSQ1NSMSC0
Command Descri
p
tion
When the switch works in standalone mode:
oap connect slot slot-number Available in user view
When the switch works in IRF mode:
oap connect chassis chassis-number slot slot-number Available in user view
NOTE:
Besides the login method mentioned in this manual, you can also log in to the LSQ1NSMSC0 through
Telnet, or the console port on the module. For more information, see
HP NetStream Monitoring Module
Configuration Guide
.
5 Upgrading the LSQ1NSMSC0
The LSQ1NSMSC0 supports software upgrade through the console port and a management Ethernet
interface on the module. For more information about how to upgrade the LSQ1NSMSC0, see HP
Security Modules Software Upgrade Guide.
The LSQ1NSMSC0 adopts independent boot and application programs, so the boot menu is different
from the switch. To upgrade the application program of the LSQ1NSMSC0, use one of the following
ways:
1. Remote upgrade at the CLI
•Use the FTP/TFTP protocol through the management Ethernet interface of the LSQ1NSMSC0.
2. Local upgrade through the boot menu
•Use the XMODEM protocol through the console port of the LSQ1NSMSC0
•Use the FTP/TFTP protocol through the management Ethernet interface of the LSQ1NSMSC0.

Manual Version: 6P103-20130125 BOM:
3123A0F9
Part number: 5998-2243
vi
NOTE:
•The LSQ1NSMSC0 does not support software upgrade through a switching and routing processing uni
t
(SRPU) of the switch.
•Using the XMODEM protocol to up
g
rade the module is relatively slow. To reduce the up
g
rade time, HP
recommends you to upgrade the module through the FTP/TFTP protocol.
•When you upgrade the LSQ1NSMSC0 through the management Ethernet interface, make sure that the
module and the FTP or TFTP server can reach each other.
6 Obtaining documentation
For module installation, see the HP 7500 Switch Series Installation Guide.
For software upgrade, see the HP Security Modules Software Upgrade Guide.
To find related documents, browse to the Manuals page of the HP Business Support Center website:
http://www.hp.com/support/manuals
© Copyright 2013 Hewlett-Packard Development Company, L.P.
The information in this document is subject to change without notice.
5998-2243