Joinwit JW3209 Series Bedienungsanleitung

www.joinwit.com
NOTICE
All trademarks and names mentioned in this
manual belong to Shanghai Joinwit.
Shanghai Joinwit has the right of the manual
interpretation.
Trademarks
All trademarks mentioned in this manual are
registered property of Joinwit.
Explanation
The content of this manual is subject to Joinwit’s
explanation.

www.joinwit.com
Contents
i. overview ----------------------------------------------------------1
ii. Technical Specifications ----------------------------------------2
iii. Technical Specifications ----------------------------------------3
iv. Instrument Introduction --------------------------------------4-5
v. Instructions for Use -----------------------------------------5-19
vi. Troubleshooting ------------------------------------------------19
vii. Care and Maintenance -------------------------------------19-20
viii. Quality Assurance ---------------------------------------------20
Attachment 1 Product Warranty Card -----------------------------------21
Attachment 2 Warranty Conditions ----------------------------------------22

www.joinwit.com
1
i、Overview
JW3209 is the company highly cost-effective optical multimeter. It’s the
integration of power meter and light source. JW3209 has the function of recording,
storing and uploading the data tested by the instrument. They are widely used in the
fiber-optic line project construction, testing and maintenance, such as digital data
network, telecommunication network and cable television.
Features:
•Easy mode switching function
•Stable Output light
•Automatic switching function of the internal source wavelength
•Detection of the frequency light
•USB data communication storage, uploading and for power supply
•Data Storage is up to 1000
•Providing the real-time data reading to be embedded in system
Applications:
•Maintenance of telecommunication project
•CATV project maintenance
•Digital data network project maintenance
•Teaching and research in optical communications
•Other fiber-optic projects

www.joinwit.com
2
ii、Technical Specifications①
Instrument model
parameters
JW3209A
JW3209C
Power meter
Calibration
wavelength(nm)
850、1300、1310、1490、1550、1625
Testing range(dBm)
-70~+6
-50~+26
Display resolution(dB)
0.01
Uncertainty(dB)
≤±0.25
linearity(dB)
≤±0.1
Frequency indentification
range
<10K
Source
Working wavelenght(nm)
1310/1550(customizable)
Typical Output Power(dBm)
-5(customizable)
Stability(dB,30min,20℃)
≤0.1dB
Modulation frequency (Hz)
CW,270Hz,1KHz,2KHz
Other parts
Power supply
3*AA 1.5Vbattery /Mini USB 5Vadapter
Auto-off time (min)
10
Battery continuous
operation time②)(h)
Source ON≥50,source off≥200
Communication Interface
Mini USB
Working temperature(℃)
-10~+60
Storage temperature(℃)
-25~+70
size(mm)
175×90×44.5
weight(g,not including
battery)
265
Notes:650 optional red light mode
①: Tested in T=23±2℃
②: Battery operating time is tested when the backlight is off, otherwise the working
time will be shorter

www.joinwit.com
3
iii、Standard Configaration
1. JW3209 instrument-------------------------------------------------------------------1pc
2. instructions------------------------------------------------------------------------------1copy
3. Data disc---------------------------------------------------------------------------------1pc
4. Mini USB data cable-------------------------------------------------------------------1pc
5. 5V USB adapter-------------------------------------------------------------------------1pc
6. 1.5V Alkaline Battery-----------------------------------------------------------------------3pcs
7. Cleaning Swabs---------------------------------------------------------------------------1pack
8. Soft Oxford cloth pack ------------------------------------------------------------------1pc
9. certificate-----------------------------------------------------------------------------------1pc
iv、Instrument Introduction
(13)
(12)

www.joinwit.com
4
图4-1
Function Introduction
①
:Turn on or off the meter
②
:Switching wavelength under test
③
:Turn on or off the backlight
④
:data testing storage\Viewing; automatic switching of source wavelength
⑤
:delete the current data record
⑥
:unit change;turn on or off the source output
⑦
:relative value measurement;system is set to zero
⑧
:change the source output frequency
⑨
:change the instrument function mode
(2)
(1)
(3)
(4)
(5)
(10)
(9)
(8)
(7)
(6)
(11)

www.joinwit.com
5
⑩
Meter display window
⑪
Mini USB interface:
data communication interface;adapter power supply interface
⑫
Laser source output port
⑬
Power meter testing input port
v、Instructions for Use
When powered by dry battery, the bottom left corner of the instrument screen will
display Auto-off sign after turning on;if no other operations within 10mins, the
instrument will be off automatically, short press “ ” the auto-off will be
cancelled.
When using external USB adapter for power supply ,the instrument will have no
auto-off function.(image 5-1)
Image 5-1
After turning on, the instrument comes into “power meter mode”
automatically(image 5-2), we can press“ ”button to come to“source
mode”(image 5-3)。
These two measurement modes can be used individually or simultaneously.
Image 5-2 image 5-3

www.joinwit.com
6
1. Power meter mode
(1) :Sequentially switching to the meter internal tested wavelength
(2) :change among dBm、dB、XW in turn (image5-4)
Image 5-4
(3) :
①Short press button,start REF function.
When the current tested value is set or changed to reference value, the instrument
comes to relative power measurement, and the top right corner of the screen will
show“Ref”
And the set dBm value。(image 5-5)
The relation of Relative power value, absolute power value and reference value:
Relative power value = absolute power value - reference value.
Image 5-5
③Long press button for about 5 seconds,ZERO function will be started
The set
reference value
Relative power
value measurement
dBm unit
dB unit
xW unit

www.joinwit.com
7
When the meter needs “System Zero”, the dust cap of the power meter detecting
port must be tightened to ensure no light input. And then long press this button
for about 5 seconds to have the automatic “System Zero” and the previous screen.
(image 5-6)
Image 5-6
(4) :
Press the button under power meter mode,SAVE function will respond.
Data storage:short press the button to save the current test data,press
button for once, the screen will show storage serial number, press again to confirm saving
and exit. (image 5-7)
Image 5-7
Date View:long press button,comes to data view interface,then short
press button,we can have a reverse look at the data recording. Again long
press button to exit.(image 5-8)
……
Storage serial number
Current data needing
storage(wavelength 、
dBmpower value)
8
Reverse
View

www.joinwit.com
8
Image 5-8
(5) button:
Delete data:in the data view status,press button to delete the current record.
2. Source mode
(1) button:Sequentially switching to the meter internal source wavelength.
(2) button:turn on or off the laser output in the source .(image 5-9)
Image 5-9
(3) button:After turning on the laser in the source module, press the button
to come to 0HZ, 270HZ, 1000HZ, 2000HZ in turn.(image 5-10)
Image 5-10
(4) button:in the source mode, open or close the automatic following switching
function of the source output wavelength.(image 5-11)