Label Neptis SMP Bedienungsanleitung

USER MANUAL
GB
SMP
English
Translation of the ORIGINAL INSTRUCTIONS
NEPTIS-SMP-16005_GB_Rel.1.0_07/2014 - CD0420GB
AUTOMATIC
SWING DOORS
FOR PEDESTRIANS

3
RECOMMENDATIONS
THIS INSTRUCTION MANUAL IS INTENDED FOR THE FINAL USER OF A LABEL
AUTOMATIC SWING DOOR SYSTEM; IT IS UNDERSTOOD THAT INSTALLATION
AND TESTING MUST HAVE BEEN CARRIED OUT BY SPECIALISED PERSONNEL.
GENERAL SAFETY WARNINGS
PROVISIONS
The automatism has been designed to be used exclusively with pedestrian automatic swing doors.
The manufacturer accepts no responsibility for incorrect product usage, as well as for any
damages arising from changes to the system made without his prior consent.
When operating the system accident prevention regulations must be observed.
REMARKS
Always meet the usage and maintenance conditions provided for by LABEL.
Maintenance and repair operations must only be performed by qualified and properly
trained personnel.
PROPER BEHAVIOUR
Only use the automatic door if it is in perfect technical conditions.
In case of failure or malfunction that might affect safety immediately contact the service
centre.
Inappropriate use of the system may cause serious injuries and damage.
BEFORE COMMISSIONING THE AUTOMATIC DOOR PLEASE CAREFULLY
READ THIS MANUAL.
!

AUTOMATIC SWING DOOR
Neptis
INDEX:
1) INDICATIVE SYSTEM DESCRIPTION page 4
2) TECHNICAL DATA 4
3) AUTOMATIC DOOR OPERATION 5
3.1) NORMAL DOOR OPERATION 5
3.2) DOOR OPERATION IN NIGHT LOCK MODE 5
3.3) SUPPORT OPERATION FOR DISABLED PEOPLE 5
4) PROGRAM SELECTORS 6
4.1) MANUAL PROGRAM SELECTOR 6
4.2) EV-MSEL MECHANICAL KEY SELECTOR 6
4.3) N-DSEL DIGITAL PROGRAMMER - USED LIKE PROGRAM SELECTOR 7
4.3.1) GENERAL PROGRAMMING MENU 9
4.3.2) PASSWORD 10
4.3.3) LANGUAGE 12
5) OPERATION IN CASE OF POWER SUPPLY FAILURE 13
6) NOTIFICATION OF ERRORS AND OPERATION PROBLEMS 14
7) MAINTENANCE 15
8) DISPOSAL 15
SMP

1) INDICATIVE SYSTEM DESCRIPTION
2) TECHNICAL DATA
NOTE:
The grey part indicates the survey
zone of radar and sensors.
2
3
4
5
6
7
EXTERNAL RADAR
INTERNAL RADAR
OPENING BUTTON
PROGRAM SELECTOR
SAFETY SENSOR FOR CLOSING
SAFETY SENSOR FOR OPENING
NEPTIS OPERATOR
ELECTRIC LOCK
FLOOR STOP
8
9
1
7
5
6
4
3
8
1
2
POWER SUPPLY
POWER
115/230Vac +/-10%, 50-60Hz
120W
MODEL OPERATOR SMP
4
9
OPERATOR WITH BATTERY DIMENSIONS
WORKING TEMPERATURE
PROTECTION DEGREE
ELECTRIC MOTOR
POWER SUPPLY OF EXTERNAL ACCESSORIES
-15°C +50°C
IP31
24Vdc
24Vdc
FREQUENCY OF USE continuous
730 x 120 x 110 mm

3) AUTOMATIC DOOR OPERATION
Switch on the power supply by means of the system switch.
The automation electronic control unit beeps shortly to indicate that the automatic door is powered.
The first opening command starts a calibration cycle during which the door wing opening speed is very low
until the end of the stroke, to find the stop points; after the delay set for the open door pause has elapsed,
the wings close back at normal speed.
3.1) NORMAL DOOR OPERATION
3.2) DOOR OPERATION IN NIGHT LOCK MODE
The door cannot be opened through the motion sensors (radar).
The door may only be opened by activating the OPEN button, or by the remote control
Spyco if applicable.
The safety function (sensors and behaviour in case of obstruction) are active and work as described
in par. 3.1. for normal operation.
WARNING!!
Always contact the assistance technician before commissioning the door, to learn how the
automation works.
When something enters the motions sensor (internal and/or external radar) detection area the door
opens and stays open until sensors detect the presence, then once the pause delay has elapsed the door
closes back.
When the manual door opening button is pressed the door opens and stays open until the command
remains active, then once the pause delay has elapsed it closes back.
If the electronic control unit has been programmed with the "push e go" function, you can also open the
door with a brief manual push.
If the safety sensor in closing detects the presence, the door immediately reopens and stays open as long
as the sensor remains engaged.
If the safety sensor in opening detects the presence, the door stops and doesn't move as long as the
sensor is engaged; it will complete the opening cycle only after the sensors disengaged.
If, during the opening motion the door bumps against an obstacle, it stops and closes back.
If, during the opening motion the door bumps against an obstacle, it stops and opens back.
3.3) SUPPORT OPERATION FOR DISABLED PEOPLE
This only applies if the electronic control unit has been programmed and set to the disabled people
operating mode.
The disabled person may open the door through a special button or by motion sensor.
The door stays open for a delay time long enough to allow the disabled person to cross the door.
All the safety functions are on.
5

4) PROGRAM SELECTORS
The program selector allows the door user to select the operating mode.
The following can be used, according to the choice: manual selector integrated in Neptis operator side, EV-MSEL key mechanical
selector or N-DSEL digital programmer.
Each program selector is described in details below.
4.1) MANUAL PROGRAM SELECTOR
The 3-position manual program selector is the basic solution provided for onboard operator.
= Bi-directional automatic program
The door automatically opens when each opening control activates.
= Free manual door
The automatic operation is disabled and door can be manually open.
= Night lock program
The door can only be open by OPEN input or radio control, if applicable.
Open door program
The door stops in complete opening position.
The key can be taken out of the selector when in any position in order to prevent the work program from undesired changes.
Open door program
The door stops in complete opening position.
Free manual door
The automatic operation is disabled and door can be manually open.
Bi-directional automatic program
The door automatically opens when each opening control activates.
Single-direction automatic program output only
To exclude the incoming detection on external radar input
Night lock program
The door can only be open by OPEN input or radio control, if applicable.
OPERATING MODE
Insert and rotate the key in EV-MSEL selector to select the program desired.
6
Can have two different
behavior, depending on
the programming of the
control unit.
Position I
Position 0
Position II
4.2) EV-MSEL MECHANICAL KEY SELECTOR

4.3) N-DSEL DIGITAL PROGRAMMER – USED LIKE PROGRAM SELECTOR
N-DSEL digital programmer can be installed in the system and used by the user like a program selector, as an alternative to manual and
mechanical selector if you need a more complete tools in terms of functions and graphs.
Select the automatic door operating mode by pressing once the button.
Each time a button is pressed, it switches from a work program to the next one.
The operating programs to be selected by button are described below
Bi-directional automatic program
The door automatically opens when each opening control activates.
Single-direction automatic program output only
To exclude the incoming detection on external radar input
Single-direction automatic program input only
To exclude the outgoing detection on internal radar input.
Open door program
The door stops in complete opening position.
Night lock program
The door can only be open by OPEN input or radio control, if applicable.
Free manual door
The automatic operation is disabled and door can be manually open.
7

Operation of other buttons located on N-DSEL program selector panel
Pedestrian opening, used in double-leaf door automated device only
To activate pedestrian opening, press the button.
the symbol on the display indicates that the function is on.
In a double leaf door, the first leaf (Master) only opens if the opening command is given by
internal or external radar inputs.
The pedestrian opening only operates in bi-directional, single-direction and open door
automatic programs.
To deactivate pedestrian opening, press again the button.
Deactivation of step-by-step operation (if enabled in the setting of the operator)
Give a pulse to F2 button to deactivate the step-by-step operation and enable the door
automatic closing. Symbol F2 on display goes ON.
Press F2 button again to activate step-by-step operation. Symbol F2 on display goes off.
F2
F1
Door opening command
Press F1 button to open the door, in bidirectional and single directional programs.
The F1 button can open the door also in the NIGHT LOCK program (depend by the setting of
the operator).
8

9
4.3.1) GENERAL PROGRAMMING MENU
The user can enter in the programming menu general when he wants to choose the preferred language in which to view texts that appear on
the display, or when he wants to enable a password to prevent access to the use of N-DSEL digital programmer.
F1
»
F1
»
F1
»
F1
»
5”
UNUSED
UNUSED
F1
»
F1
»
F1
»
In the following sections explain how to manage user passwords and how to select the language.
“LANGUAGE” SECTION
“PASSWORD
MANAGEMENT” SECTION
EXIT EXIT EXIT EXIT
ENTER
EXIT EXIT EXITEXIT
ENTER
DIAGRAM 1
SECTION RESERVED FOR
TECHNICAL SERVICE
SECTION RESERVED FOR
TECHNICAL SERVICE
SECTION RESERVED FOR
TECHNICAL SERVICE
SECTION RESERVED FOR
TECHNICAL SERVICE

10
4.3.2) PASSWORD
To prevent changes in the work program of the door, you can set a password that must be entered each time you act on the N-DSEL
programmer.
To enable the password, do the following:
1. Press the SET button for 5 second to enter the programming menù general
(see Diagram 1 in par. 4.3.1)
2. Press the F1 button five times to move to the submenu Password Manager.
3. Press the Enter button to enter the "Password Management".
PASSWORD MANAGEMENT
In this section are two passwords that can be used by the end user, the primary password and password service.
The technical password is reserved only to the technical personnel responsible for installation and maintenance.
PRIMARY PASSWORD (for the system's owner-user)
It is a 5-character password used by the user to prevent unauthorized persons from having access to N-DSEL programmer and change the
work program.
Using a primary password is optional and must be enabled by system's owner.
Default preset primary password is “A-A-A-A-A”.
WARNING!
When enabling the password, be very careful not to forget the access combination.
SERVICE PASSWORD (for user)
It is a 5-character password that the system's owner may divulge to persons to be authorized to use N-DSEL programmer.
The service password only allows changing the automatic door work program.
Default preset service password is “A-A-A-A-A”.
To change the service password, it is necessary to have access by primary password.
Use button to move the selection arrow downward, F2 button to move the arrow upward.
HOW TO CHANGE THE PRIMARY PASSWORD
Select “PRIMARY PASSWORD”
Press OK (F1) button.
Type the default preset primary password “A-A-A-A-A” by pressing 5 times on A
button.
Type the new primary password, selecting a combination of 5 characters from the
letters A-B-C-D.
Andere Handbücher für Neptis SMP
1
Inhaltsverzeichnis
Andere Label Türöffnungssystem Handbücher

Label
Label ETERNA 70 Bedienungsanleitung

Label
Label NEXT 120s Bedienungsanleitung

Label
Label EVOLUS Handbuch

Label
Label ETERNA 90 EASY Bedienungsanleitung

Label
Label Neptis SLT-B Bedienungsanleitung

Label
Label NEXT 75 Bedienungsanleitung

Label
Label Neptis SMP Bedienungsanleitung

Label
Label NEXT 75 Bedienungsanleitung

Label
Label T-NFC Bedienungsanleitung

Label
Label NEPTIS PLUS Bedienungsanleitung