Maxforce ELITE e-Agitator Leitfaden

M10442-20-A(888) 257-7729 | maxforce.com
Operation & Parts
MAXFORCE
ELITE e-Agitator
M10442-20-A
Product Description
AGITATOR, HIGH VIS, ELEC, ELITE
2845 W Service Rd Eagan, MN 55121
WARNING
FIRE AND EXPLOSION HAZARD
Use only non-flammable or water-based materials
with this equipment. Do not use materials having
flash points lower than 140° F (60° C). For more
information about your material, request Safety
Data Sheet (SDS) from the supplier. Not for use in
explosive environments or environments where
ignitable vapors may be present. Inspect the work
area for potential hazards before operating this
equipment.
Manual Revisions
Revision Date Serial No
A7/13/23 9066742—

2(888) 257-7729 | maxforce.com M10442-20-A
Table of Contents
Safety 3
Equipment Layout 4
Control Panel Layout 5
Specifications 6
Operation 7
Technical Data
Dimensions 8
Parts 9
Wiring Diagram 13
Warranty 16
For parts, service, and technical assistance,
contact your equipment distributer:

M10442-20-A(888) 257-7729 | maxforce.com 3
Safety
General Safety Information
READ THE MANUAL
• Ensure any operator of this equipment has read and
understands the manual before operating.
• Do not attempt to repair or modify this equipment
without consulting the manual.
EQUIPMENT MISUSE HAZARD
• Equipment misuse can cause the equipment to rupture
or malfunction and result in serious injury.
• This equipment is for professional use only.
• Read all instruction manuals, tags, and labels before
operating the equipment.
• Use the equipment only for its intended purpose. If you
are not sure, call your distributer.
• Do not alter or modify this equipment. Use only genuine
OEM parts.
• Check equipment daily. Repair or replace worn or
damaged parts immediately.
• Comply with all applicable local, state, and national fire,
electrical, and safety regulations
• Do not leave the work area while equipment is
operating.
FIRE AND EXPLOSION HAZARD
• Improper grounding, poor ventilation, open flames or
sparks can cause a hazardous condition and result in a
fire or explosion and serious injury.
• Keep the equipment area free of debris, including
solvent, rags and uncontained fuel.
• Use only with non-flammable or water-based materials
• Keep a working fire extinguisher on hand at all times in
the work area.
Equipment Hazards & Warnings
DANGER
• Do NOT use near solvents or solvent based materials
• Do NOT use near flammable materials or in poorly
ventilated areas
• The motor and associated components are not rated for
use in explosive environments.
WARNING
• Read the operators manual before starting this unit.
Failure to adhere to instructions can result in severe
personal injury.
• Do NOT operate equipment that is not mounted in a 2”
bung on a 55 gallon drum.
• To avoid potential injury, disconnect power cord prior to
transporting or moving equipment from one drum to the
next drum.
• Keep clear of moving parts, do not operate equipment
with enclosure panels removed.
CAUTION
• To avoid electrical shock, disconnect power cord prior
to electrical system service
• Motor enclosure may get warm to the touch when
equipment is run for long periods of time.

4(888) 257-7729 | maxforce.com M10442-20-A
Equipment Layout
A
B
G
E
D
C
e-Agitator Components
A110/120VAC Plug
BCooling Air Intake
CMotor Start/Stop
DMotor RPM Display
EON/OFF Switch
F2” NPT Bung Adapter
GMixing Shaft
HMixing Blade (3 Total)
H
F

M10442-20-A(888) 257-7729 | maxforce.com 5
Control Panel Layout
Control Panel
APower ON/OFF Switch
BMotor START/STOP Pushbutton
CRPM SET Button
DRPM Up Arrow
ERPM Down Arrow
FRPM Display/Setpoint
B
A
SET
RPM E
D
C
F

6(888) 257-7729 | maxforce.com M10442-20-A
Specifications
Performance
Output Speed 0-500 rpm
Output Torque 55 in-lbs
Power
Voltage 110/120 VAC
Amperage 4A
Rated Motor Power 378 W
Dimensions
Length 7.1”
Width 5.6”
Height 47” (12.1” From Top of Drum)
Weight 16.5 lbs
Bung Adapter Size 2” NPT
Wetted Parts Stainless Steel

M10442-20-A(888) 257-7729 | maxforce.com 7
Operation
Install the agitator
1. Due to differing drum heights, the
expanding agitator blades may need to
be adjusted up and down the agitator
shaft. Loosen the set screws on each
blade and adjust to the appropriate
height, then re tighten securely to the
shaft.
2. Install the agitator into a 55 gallon drum
by folding the expanding blades and
inserting them into the 2” NPT female
bung on the topside of the drum. Thread
the agitator clockwise to tighten.
NOTICE
• Ensure the agitator shaft is not contacting the bottom of
the drum.
• The agitator should be hand tightened into the drum.
Operating the agitator
1. With the agitator fully tightened into a
drum of material, connect the agitator to
a 120VAC power source with the
attached plug.
2. Switch the power switch to the ON
position. The RPM display will illuminate
and the cooling fan will turn on.
CAUTION
• Never operate the agitator in an empty drum or not
installed in a drum.
• Do not attempt to use the agitator while holding it, or
otherwise supporting it in a smaller container.
3. To change the desired RPM setpoint,
press the up or down arrow on the RPM
display. The number that is displayed is
the RPM setpoint. Use the arrows to
adjust the RPM setpoint to the desired
value, and then press the SET button to
lock the setpoint.
NOTICE
• The agitator will store the previous RPM setpoint from
the last time it was shutdown.
• If the SET button is not pressed, after approximately 3
seconds the unit will revert to the previous RPM
setpoint.
4. Press the motor START/STOP button to
begin agitating. The agitator will begin
turning, and the agitator RPM will display
on the screen. It may take a few moments
to adjust it’s speed to the RPM setpoint.
5. To stop the agitator, press the motor
START/STOP pushbutton again, or
switch the power switch to the OFF
position. It may take a few moments for
the agitators blades to slow.
6. When finished for the day, stop the
agitator motor, and unplug the 120V
power cord.

8(888) 257-7729 | maxforce.com M10442-20-A
Technical Data
Agitator Dimensions

M10442-20-A(888) 257-7729 | maxforce.com 9
Parts
Motor Assembly
Ref. Part No. Description Qty
1V10442-50 BRUSHLESS DC GEARMOTOR 1
2C10442-68 SHAFT COUPLER 1
3C10442-70 BUNG MOUNT WELDMENT 1
4C10442-84 MOUNT PLATE, HV AGITATOR 1
5V10442-35 SOCKET HEAD CAP SCREW 1
6V10442-36 DOG POINT SET SCREW 2
7V10442-60 THERMOSTAT 1
19 V10442-48 PRESS-FIT NUT 6
26 C10442-89 THERMO SWITCH MOUNT 1
6

10 (888) 257-7729 | maxforce.com M10442-20-A
Power Supply, Enclosure Parts — Cont.
Ref. Part No. Description Qty
8C10442-86 COVER, RIGHT 1
9C10442-87 COVER, LEFT 1
10 V10442-62 BUTTON HEAD SCREW 4
12 V10442-67 STRAING RELIEF ELBOW 1
13 V10442-68 LOCKING NUT 1
14 V10442-52 POWER SUPPLY 1
46 V10443-49 SPRING PIN 1
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis