Measurlogic DTS 310 Bedienungsanleitung

©Measurlogic Page 1
MQ0052-17A
7334 S. Alton Way, Centennial CO 80112
Tel: 877-777-6567 Tel: 303-805-5252 Fax: 425-799-4780
e-mail: info@measurlogic.com
web: www.measurlogic.com
DTS 310
DIN – Rail Mounted, Indoor Rated
Revenue Grade Electrical Sub-meter

©Measurlogic Page 2
MQ0052-17A
7334 S. Alton Way, Centennial CO 80112
Tel: 877-777-6567 Tel: 303-805-5252 Fax: 425-799-4780
e-mail: info@measurlogic.com
web: www.measurlogic.com
1 PRODUCT OVERVIEW......................................................................................................................................................... 3
1.1 SUPPLIED ITEMS ..................................................................................................................................................................... 3
1.2 DOCUMENT CONVENTIONS ...................................................................................................................................................... 4
1.3 PRODUCT SPECIFICATION ......................................................................................................................................................... 4
1.3.1 Current Inputs ............................................................................................................................................................ 4
1.3.2 Service Type ............................................................................................................................................................... 4
1.4 DTS 310 LAYOUT................................................................................................................................................................... 5
2 INSTALLATION ................................................................................................................................................................... 6
2.1 ENVIRONMENT....................................................................................................................................................................... 6
2.2 SAFETY GUIDELINES ................................................................................................................................................................ 6
2.3 PRODUCT DIMENSIONS............................................................................................................................................................ 7
2.4 MOUNTING REQUIREMENTS AND GUIDELINES ............................................................................................................................. 7
3 CONNECTING TO THE DTS 310 ........................................................................................................................................... 8
3.1 WIRING VOLTAGE AND CURRENT INPUTS .................................................................................................................................... 8
3.1.1 Wiring Examples ........................................................................................................................................................ 8
3.2 CONNECTING MULTIPLE LOADS................................................................................................................................................. 9
3.3 DC AUXILIARY POWER........................................................................................................................................................... 10
4 MAINTENANCE AND SERVICE........................................................................................................................................... 11
5 DTS 310 COMMUNICATIONS INTERFACE.......................................................................................................................... 11
5.1 MODBUS AND BACNET RS-485 2-WIRE COMMUNICATIONS ....................................................................................................... 11
5.2 LONWORKS TP/FT – 10 COMMUNICATIONS............................................................................................................................. 12
5.2.1 Wiring Requirements ............................................................................................................................................... 12
5.2.2 Adding the DTS 310 to an existing LonWorks Network via Service Pin .................................................................... 12
5.2.3 Adding the DTS 310 to an existing LonWorks Network via Neuron ID .................................................................... 12
5.3 ETHERNET COMMUNICATIONS ................................................................................................................................................ 13
5.4 KWHPULSE OUTPUT (MODEL DEPENDENT).............................................................................................................................. 13
5.5 CONFIGURING DIP SWITCHES – COMMUNICATION AND PULSE OUTPUT SETTINGS............................................................................ 13
5.5.1 Configuring DIP Switches – Modbus RTU................................................................................................................. 14
5.5.2 Configuring DIP Switches – BACnet MS/TP .............................................................................................................. 14
5.5.3 Configuring DIP Switches – Pulse Output................................................................................................................. 15
6 LED DEFINITIONS ............................................................................................................................................................. 16
6.1 STATUS LED........................................................................................................................................................................ 16
6.2 REMOTE LED....................................................................................................................................................................... 16
6.3 PULSE LED.......................................................................................................................................................................... 17
7 INSTALLATION OF DTS CONFIG AND MONITORING SOFTWARE ....................................................................................... 17
8 MAINTENANCE AND SERVICE........................................................................................................................................... 17
8.1 CLEANING INSTRUCTIONS ....................................................................................................................................................... 17

©Measurlogic Page 3
MQ0052-17A
7334 S. Alton Way, Centennial CO 80112
Tel: 877-777-6567 Tel: 303-805-5252 Fax: 425-799-4780
e-mail: info@measurlogic.com
web: www.measurlogic.com
1 PRODUCT OVERVIEW
The one revenue grade meter for all applications.
Your DTS 310 energy sub-meter is one of the most versatile meters available on the market. The DTS 310 can
operate in any environment, requires no external power source to operate, and works with all UL or ETL listed
333mV current transformers.
For ease of installation, the DTS 310 is designed to be compact and fit into most DIN-rail systems.
Some of the exciting features provided with the DTS 310 are
Easy to attach pluggable terminals
RS-485 or Ethernet Communications depending on model
Auto-topology Phase Detection and on-board CT Algorithms for automatic correction of reversed field
mounted CTs
For remote configurability, your DTS 310 comes with our freely downloadable
DTS Config
software tool
The DTS 310 provides you very accurate data acquisition and is certified to ANSI C12.20 Class 0.5 Revenue
Grade.
Also, if in the future, you decide to integrate renewable energy sources, the DTS 310 will conveniently operate as
a Bi-Directional NET meter. Easily integrates with Building Automation Systems and Energy Monitoring Softw are.
Designed and Manufactured in the USA and complies with the Buy American Provisions of ARRA Section 1605.
Thank you for choosing Measurlogic and a meter from the DTS Family.
1.1 Supplied Items
Check that the meter and equipment matches your order specifications and has not been damaged during
shipping. Verify that the following item(s) match with the corresponding model from the data sheet :
Quick Start Guide
DTS 310 power & energy meter
10-Pin green pluggable screw terminal connector for Voltage inputs
6-Pin green pluggable screw terminal connector for Current inputs
3-Pin green pluggable screw terminal connector for Remote RS-485 Communications depending on model
6-Pin green pluggable screw terminal connector for digital I/O depending on model

©Measurlogic Page 4
MQ0052-17A
7334 S. Alton Way, Centennial CO 80112
Tel: 877-777-6567 Tel: 303-805-5252 Fax: 425-799-4780
e-mail: info@measurlogic.com
web: www.measurlogic.com
1.2 Document Conventions
SYMBOLS
ATTENTION – PLEASE CONSULT THE
INSTALLATION MANUAL
WARNING – RISK OF ELECTRICAL
SHOCK
1.3 Product Specification
WARNING
The DTS 310 is intended for
480V L-L Measurement Category III use.
Do NOT exceed this usage.
Use the model number of the DTS 310 to verify that
it is suitable for the voltage, type and category
of the installation.
Failure to use the correct CT’s, and/or connecting too high
a voltage can result in death or personal injury,
and may permanently damage the DTS meter.
DTS 310 - Ax-xx-x-F-xx
1.3.1 Current Inputs
Current
Inputs
Value
Description
Notes
A
3
333mV CT
Any 333mV CT is acceptable
9
Unburdened CT
Only use the CT’s that came with the unit
1.3.2 Service Type
Service Type
Value
Description
Neutral Required
Neutral Optional
F
N
(1P 2W, 1P 3W, 3P 4W) 120 – 277Vac L– N
●
2
(3P 3/4W) 208 – 240 Vac L– L
●
4
(3P 3W) 480 Vac L– L
●

©Measurlogic Page 5
MQ0052-17A
7334 S. Alton Way, Centennial CO 80112
Tel: 877-777-6567 Tel: 303-805-5252 Fax: 425-799-4780
e-mail: info@measurlogic.com
web: www.measurlogic.com
1.4 DTS 310 Layout
Current Connections
Section 3.1 pg 8
Voltage Connections
Section 3.1 pg 8
Remote Communications
Section 5 pg 11
Digital I/O
Section 5.4 pg 13
ETL Mark
DTS 310 Meter Model Number
Serial Communications
Section 5.1 pg 11
Dip Switches
Section 5.5 pg 13
Status LEDs
Section 6.1 pg 16
Pulse LED
Section 6.3 pg 17
Remote LED
Section 6.2 pg 16
DC Auxiliary Power
Section 3.1 pg 8
Ethernet Communications
Section 5.3 pg 13

©Measurlogic Page 6
MQ0052-17A
7334 S. Alton Way, Centennial CO 80112
Tel: 877-777-6567 Tel: 303-805-5252 Fax: 425-799-4780
e-mail: info@measurlogic.com
web: www.measurlogic.com
2 INSTALLATION
2.1 Environment
Operating Temperature: -4oF to 131oF (-20oC to 55oC)
Storage Temperature: -40oF to 185oF (-40oC to 85oC)
Relative Humidity: 5% to 95% (non-condensing)
Operating Altitude: Up to 2,000m
2.2 Safety Guidelines
WARNING
The following installation instructions are intended for qualified personnel only. To avoid
the risk of electrical shock and personal injury, do not perform additional tasks not stated
in this procedure unless you are qualified to do so.
Always adhere to the following safety guidelines:
Only qualified personnel or licensed electricians should handle the installation. Input voltages to
the DTS 310 can be hazardous.
Follow all applicable local and national electric codes.
Verify input voltage and current are within thresholds for the specific DTS 310 model. (See Product
Specification on page 4)
Use only UL or ETL listed current transformers.
ONLY USE CURRENT TRANSFORMERS WITH OUTPUTS THAT ARE COMPATIBLE WITH THE
MODEL OF DTS 310 (SEE SECTION 1.3.1). THE USE OF ANY OTHER CURRENT
TRANSFORMER CAN RESULT IN PERMANENT DAMAGE TO THE DTS 310.
Avoid any electrostatic discharge prior to working on the DTS 310 by first touching a grounded
structure prior to handling the DTS 310.
Before applying power make sure that all current transformer and voltage connections are securely
connected to the input terminals of the DTS 310.
If the DTS 310 is installed incorrectly any built in safety features may no longer be functional.
Before handling the DTS 310 ensure that all power running to the DTS 310 is removed.
The DTS 310 is for indoor use only, and MUST be mounted in a NEC compliant enclosure suitable for
the environmental conditions and locked with a user supplied lock.

©Measurlogic Page 7
MQ0052-17A
7334 S. Alton Way, Centennial CO 80112
Tel: 877-777-6567 Tel: 303-805-5252 Fax: 425-799-4780
e-mail: info@measurlogic.com
web: www.measurlogic.com
2.3 Product Dimensions
2.4 Mounting Requirements and Guidelines
ATTENTION
Make sure to follow the following mounting requirements
and guidelines when mounting the DTS 310.
When mounting the DTS 310 make sure to follow these guidelines:
Mount the DTS 310 as close as possible to the electrical panel being monitored.
Make sure that there is at least 4” of clearance above and below the DTS 310 for wiring and
connector clearance and ¼” of clearance on both sides for cooling.
Position the DTS 310 such that the labeling can be read from the upright position.
Only UL or ETL rated conduits and glands should be used.
It is recommended that two separate conduits be run for voltage and current connections.
User Supplied UL or ETL certified 2A fast-blow fuses need to be installed between the Voltage
inputs of the DTS 310 and panel being monitored. Recommended Littelfuse BLS002 or equivalent.
14 to 12 AWG wire should be used for the voltage and ground with 300V or 600V insulation
depending on installation type and according to the table below.
A UL or ETL certified 600V circuit-breaker or fused disconnect must be installed within easy reach of
the DTS 310. The circuit-breaker or fused disconnect must be clearly marked as being “the
disconnecting device” for the DTS 310. See table below for the breaker and wire gauge to use.
WIRE & BREAKER GUIDE
Gauge of Wire
Recommended Breaker
14 AWG
15 Amp 600V 3-Pole Breaker
12 AWG
20 Amp 600V 3-Pole Breaker

©Measurlogic Page 8
MQ0052-17A
7334 S. Alton Way, Centennial CO 80112
Tel: 877-777-6567 Tel: 303-805-5252 Fax: 425-799-4780
e-mail: info@measurlogic.com
web: www.measurlogic.com
3 CONNECTING TO THE DTS 310
3.1 Wiring Voltage and Current Inputs
3.1.1 Wiring Examples
ATTENTION
Make sure that your model of DTS 310 is approved for the
following wiring guidelines.
Note: CTs should be connected to the same panel as the
voltage connections.
Load
Single Phase 2/3 Wire
A
N
B
C
3-Phase with Optional Neutral (Model Dependent)
Load
A
N
B
C

©Measurlogic Page 9
MQ0052-17A
7334 S. Alton Way, Centennial CO 80112
Tel: 877-777-6567 Tel: 303-805-5252 Fax: 425-799-4780
e-mail: info@measurlogic.com
web: www.measurlogic.com
A
N
B
C
3.2 Connecting Multiple Loads
The DTS 310 allows for ease and flexibility when monitoring multiple branches. The DTS 310 allows multiple CT
sensors to be connected in parallel via the green pluggable screw terminal.
When using parallel CT sensors, the following guidelines must be followed to ensure accurat e measuring.
All CT sensors must have a 333mV output.
All CT sensors must be of the same manufacturer/model number and current rating.
A full set of CT sensors must be used for each load.
The pair of wires from the CT sensor to the green pluggable scre w terminal must be twisted.
All CT sensors must be terminated at the green pluggable screw terminal .
A maximum of 3 loads can be monitored at once (Contact Measurlogic if more than 3 loads must be
monitored).
The measured phase current will be the total current across all the loads on that phase.
The CT primary rating for the DTS 310 must be set to the CT rating * Number of CT sets.
The example below shows how to calculate the service current for figure 3.2.1.
Service Current for Figure 3.2.1
Number of CT Sensor Sets
2
CT Rating
100 Amps
CT Primary
200 Amps
Figure 3.2.1
A
B
C
Load 1
A
B
C
Load 2

©Measurlogic Page 10
MQ0052-17A
7334 S. Alton Way, Centennial CO 80112
Tel: 877-777-6567 Tel: 303-805-5252 Fax: 425-799-4780
e-mail: info@measurlogic.com
web: www.measurlogic.com
3.3 DC Auxiliary Power
The most common way to power the DTS 310 meter is through the voltage connections. If this situation is not
ideal the DTS 310 meter can be powered through a user supplied DC source.
ATTENTION
Check the DTS 310 model number for the correct DC
voltage to power the DTS 310 through the auxiliary.
WARNING
Make sure that all power is removed from the DTS 310 prior to wiring the DC auxiliary
DTS 310 - xx-xx-x-F-xx
Service Type
Value
Description
F
1
12Vdc external power
3
24 Vdc external power
5
48 Vdc external power
DC Source
+ ‒
Andere Handbücher für DTS 310
3
Inhaltsverzeichnis
Andere Measurlogic Messgerät Handbücher

Measurlogic
Measurlogic DTS 310 Bedienungsanleitung

Measurlogic
Measurlogic DTS 310 Leitfaden

Measurlogic
Measurlogic DTS 307 Bedienungsanleitung

Measurlogic
Measurlogic DTS DC Bedienungsanleitung

Measurlogic
Measurlogic DTS 307 Bedienungsanleitung

Measurlogic
Measurlogic DTS 310-3 SB-A Series Bedienungsanleitung

Measurlogic
Measurlogic DTS 310 Bedienungsanleitung

Measurlogic
Measurlogic DTS SMX Bedienungsanleitung