CONTROL VALVE
1. Wrap two turns of 1/2” wide teflon tape on the three threaded shanks of the control valve(1).Wrap the tape in
a clockwise direction.
2. From the inside of the shower cabinet, insert the threaded shanks of the control valve through the pre-drilled
mounting holes, secure on outside with locknuts. Hand tighten until a snug fit is obtained.
1” DIA.,3 HOLES REQ’D
FIG.1
VALVE & SHOWER HEAD ASSEMBLY
MODEL NO. 68.600 HW
Installation of this shower valve and spray head requires that 4 (four) 1” diameter holes be drilled into the shower
cabinet side wall, three holes are required for mounting the control valve, the remaining hole is for the spray head.
See Figure 1 for control valve hole spacing; the spray head can be mounted at any desired height. The shower
cabinet side wall can be easily drilled using a power drill and 1”diameter hole saw. All pipe fitting connections require
1/2”-14NPSM threads. Refer to PARTS ILLUSTRATION on back.
NOTE: Do not use pipe dope or other
petroleum based compounds in place of
the teflon tape specified, or on any of the
shower or faucet components.
SHOWER HEAD
1. The shower head is equipped with a built-in flow restrictor, for water conservation. This will limit the flow of water
to 2.0 GPM@80 PSI.
2. Wrap two turn of 1/2” wide teflon tape (obtainable at most hardware/plumbing stores) on the shower arm.
(3)Wrap the tape in a clockwise direction.
3. Slide the flange nut (4) onto the shower arm.(3) Hand tighten until a snug fit is obtained.
4. Screw the shower head (2)onto the shower arm/flange nut assembly. Hand tighten until a snug fit is obtained.
Make water hook-up and riser connection in full compliance with local code requirements.