The New Generation of Wireless
Access Control Systems

AccessZone ® - GC500 Series – GC501-GC504 User Manual
AccessZone® System - A Key to a Safer Future
Congratulations on choosing an AccessZone® Access Control S stem. It is
a flexible and eas to use s stem for controlling access to doors and gates
to private homes, shops and small and middle size companies. It enables
quick configuration with a few simple commands entered on a standard
mobile phone with Bluetooth without installing an software. No license
or subscription is required.
This manual covers the eas configuration of the AccessZone® GC500
series of stand-alone Access Control S stems via a mobile phone:
GC501 – 2 administrators and 5 users
GC502 – 2 administrators and 10 users
GC503 – 2 administrators and 20 users
GC504 – 2 administrators and 50 users
A GC400 series is also available with Wiegand Bus for use with existing
access control s stems:
GC401-GC404 – 10, 50, 200 and 400 users, 10 Wiegand formats
Or the GC600 series with Bluetooth wireless PC interface for eas
configuration with the PC tool PcManagement:
GC601-GC604 – 10, 50, 200 and 400 users and 128 events log
The GC600 series has a Bluetooth PC interface and can be configured and used in combination
with the larger GC2000, GC3000 and GC4000 Access Control S stems.
Please see the GC500/GC600 series Installation Manual for instructions on how to install the
s stem.
All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010-07-06 US 1 18
Copyright © 2005-2010 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web www mvc-data com E-mail info@mvc-data com Phone +45 25 12 84 02
2/34
AccessZone® GC500 with
4 inputs/2 outputs
Form factor 127 x 47 x 8 mm
Get easy and seamless accesses to the secured areas with your mobile phone
working as a secure access key from a distance of 0.1 up to 10 meters.

AccessZone ® - GC500 Series – GC501-GC504 User Manual
Table of Contents
1 Disclaimer .........................................................................................................................................5
2 Introduction.......................................................................................................................................6
3 Securit Precautions..........................................................................................................................7
4 S stem Overview...............................................................................................................................8
5 I/O Description..................................................................................................................................8
5.1 Inputs..........................................................................................................................................8
5.2 Outputs.......................................................................................................................................8
6 LED Status..........................................................................................................................................9
6.1 Power Up....................................................................................................................................9
6.2 Blue LED......................................................................................................................................9
6.3 Green LED / Ext. Red LED...........................................................................................................9
6.4 Red LED / Ext. Green LED...........................................................................................................9
7 How to Configure the S stem..........................................................................................................10
7.1 Commands via Mobile..............................................................................................................10
7.2 How to enter Configuration Mode...........................................................................................11
7.3 How to enter S stem Commands – Configuration Mode........................................................12
7.3.1 If the s stem doesn’t respond to a command:.................................................................12
7.4 How to Add or Delete Users – Normal Operation...................................................................13
7.4.1 If the s stem doesn’t respond to a command:.................................................................13
8 S stem Commands..........................................................................................................................14
8.1 Change 8 digit Master PIN Code Command.............................................................................14
8.2 Add new User Command.........................................................................................................15
8.3 Delete User Command.............................................................................................................17
8.4 Change S stem Configuration Command 1.............................................................................18
8.5 Change S stem Configuration Command 2 – Advanced settings............................................20
9 Request Exit – REX Push Button .....................................................................................................22
10 Alarm Arming and Disarming........................................................................................................22
10.1 Disarming the Alarm...............................................................................................................22
10.2 Arming the Alarm...................................................................................................................22
10.3 Timing Diagram of the outputs – Normal Access and Arming the Alarm..............................23
10.4 Timing Diagram of the Outputs – Normal Access and Reject Arming of the Alarm.............. 23
11 Virtual Ke pad...............................................................................................................................24
11.1 Virtual Ke pad onl Mode......................................................................................................24
11.2 Virtual Ke pad Mixed Mode...................................................................................................24
12 User Access Ke Setup...................................................................................................................25
12.1 Mobile Phone as Ke ..............................................................................................................25
12.2 GPS Ke as Ke ........................................................................................................................26
12.3 AccessZone Bluetooth Tags....................................................................................................26
13 Door/Gate Output T pe................................................................................................................27
13.1 Pulse.......................................................................................................................................27
13.2 Level........................................................................................................................................27
13.3 Latched (toggle)......................................................................................................................27
14 Access Detection Range................................................................................................................28
14.1 Detection Range Command Examples...................................................................................28
14.2 Detection range is to short.....................................................................................................29
14.3 Detection range is too long....................................................................................................29
15 Default Factor S stem Settings....................................................................................................30
15.1 Restore Factor Default S stem Settings...............................................................................30
All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010-07-06 US 1 18
Copyright © 2005-2010 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web www mvc-data com E-mail info@mvc-data com Phone +45 25 12 84 02
3/34

AccessZone ® - GC500 Series – GC501-GC504 User Manual
16 Appendix A – User Log Template..................................................................................................31
17 Appendix B – S stem Master PIN Code Log Template..................................................................31
18 Appendix C – S stem Configuration Log Template.......................................................................31
19 Appendix B – Quick Guide:............................................................................................................32
19.1 Mobile Phone used for Adding and Deleting Users – Normal Operation:.............................32
19.2 Mobile Phone used for S stem Commands - S stem Configuration Mode:..........................33
19.3 Mobile Phone as Access Ke : ................................................................................................34
All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010-07-06 US 1 18
Copyright © 2005-2010 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web www mvc-data com E-mail info@mvc-data com Phone +45 25 12 84 02
4/34

AccessZone ® - GC500 Series – GC501-GC504 User Manual
1 Disclaimer
All rights reserved.
MVC-Data ApS assumes no responsibilit for an errors in this manual.
MVC-Data ApS is constantl working to improve its products and offer new features in
collaboration with customers and partners. Therefore, MVC-Data ApS reserves the right to change
the hardware, software and / or specifications without notice and shall have no obligation to
update the information contained in this manual.
MVC-Data ApS's products are not authorized for use as s stem-critical components in life
supporting devices or s stems.
AccessZone® is a registered trademark of MVC-Data ApS. The Bluetooth trademark is owned b
the Bluetooth SIG. All other trademarks are owned b their respective owners.
The displa ed screens ma differ and depends on the mobile phone used for configuration.
Cop right © 2005-2010 MVC-Data ApS
All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010-07-06 US 1 17
Copyright © 2005-2010 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web www mvc-data com E-mail info@mvc-data com Phone +45 25 12 84 02
5/34

AccessZone ® - GC500 Series – GC501-GC504 User Manual
2 Introduction
The AccessZone GC500 series GC501-GC504 are stand-alone access control s stems. The are well
suited for use in private homes, shops and minor companies.
The are unique wireless access control s stems built on Bluetooth wireless technolog – a
wireless technolog that operates in the license free ISM band at 2.4 GHz.
The s stems onl allow access to users who can be identified b their unique Ke ID and optional a
4 digit PIN code for increased securit . The used mobile phones or other Bluetooth devices must
be set to “visible” to allow them to be discovered b the s stem.
The GC500 series eliminates the need for mechanical readers and ke boards outside the secured
area. This removes the risk for propert damage and breakdown due to harsh environmental
conditions and heav use.
Please refer to the GC500 Firmware Release Note for the latest changes.
The latest firmware versions introduces:
New improved validation of Bluetooth module BD address
The BD address is read back and compared against factor value in production data
Improved end-user notification when waiting for PIN code
The green LED in the middle starts flashing when a valid user has been detected and it is
waiting for user to enter the PIN code
Added support for a new “Re-trig Gate Open” feature
This feature can be enabled/diabled b a s stem command and it will re-trig the opening
time as long as the same valid user is detected. I.e. the door/gate will not be closed
All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010-07-06 US 1 17
Copyright © 2005-2010 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web www mvc-data com E-mail info@mvc-data com Phone +45 25 12 84 02
6/34

AccessZone ® - GC500 Series – GC501-GC504 User Manual
3 Security Precautions
Several securit precautions have been implemented in the s stem to make it safe to use.
The s stem will onl accept s stem configuration commands in a special configuration mode (refer
to section 7.2 How to enter Configuration Mode).
All s stem configuration commands are entered b temporaril changing the mobile phones
friendl name
1)
and must be followed b a unique 8 digit Master PIN code when prompt. The
Master PIN code should onl be known to a limited number of people (s stem administrators).
The 8 digit Master PIN code should be changed and is unique for each GC501-GC504 s stem. It can
be entered from an Bluetooth enabled mobile phone. Please change this PIN code before
continuing
Two privileged users (administrators) can add and delete users at an time. Refer to section 7.4
How to Add or Delete Users – Normal Operation.
1)
Caution
The Bluetooth friendly name feature is used for commands and can be read from another
Bluetooth device from the distance (typically up to 10 meters).
Therefore it is highly recommended to immediately change the Bluetooth friendly name again or
make the mobile phone invisibly to avoid that unauthorized people read the commands
containing vital user information.
All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010-07-06 US 1 17
Copyright © 2005-2010 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web www mvc-data com E-mail info@mvc-data com Phone +45 25 12 84 02
7/34

AccessZone ® - GC500 Series – GC501-GC504 User Manual
4 System Overview
This section presents a s stem overview with an I/O description:
5 I/O Description
GC500 series have 4 inputs and 2 outputs.
The active levels (high ‘1’/low ‘0’), when an action is performed, can be configured (inverted).
Please refer to section 8.5 Change S stem Configuration Command 2 – Advanced settings for more
details.
5 1 Inputs
Input 1 (IN1) - Block Operation for preventing an door or gate activation
Input 2 (IN2) - REX Button for Exit and Alarm arming/disarming
Input 3 (IN3) - External control of Red (dual) LED
Input 4 (IN4) - External control of Green (dual) LED
5 2 Outputs
Open collector t pe (500mA):
Output 1 (OC1) - Alarm Arm and Disarm/Light Control Switch
Output 2 (OC2) - Door lock/Gate Control
Please see the GC500 series Installation Manual for instructions on how to install the s stem.
All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010-07-06 US 1 17
Copyright © 2005-2010 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web www mvc-data com E-mail info@mvc-data com Phone +45 25 12 84 02
8/34
Input 1 (IN1)
Block Operation
(Prevents an door/
gate activation)
Output 2 (OC2)
(Pulse/Level/Latched)
Door lock/gate control
Output 1 (OC1)
(Level/Latched)
Alarm Arm and Disarm/
Light Control Switch
Input 3/4 (IN3/IN4)
External Red LED (IN3)
External Green LED (IN4)
Input 2 (IN2)
REX Button and
Alarm arm/
Alarm reject arming

AccessZone ® - GC500 Series – GC501-GC504 User Manual
6 LED Status
The GC500/GC600 series have 3 internall controlled LEDs (Blue,
Green and Red) and two externall controlled LEDs (Red and
Green) for s stem indications.
The Green LED (mid) is a dual LED with an additional Red
LED controlled though input 3 (Orange core)
The Red LED (right) is a dual LED with an additional Green
LED controlled though input 4 (Blue core)
6 1 Power Up
The Blue LED and Red LED will light for 2 seconds from power up. This is the bootloader waiting for
new firmware. Will call the application if new firmware is not received.
6 2 Blue LED
Normal Mode - the Blue LED is solid on. It flashes shortl when an Bluetooth device ID is read
from a nearb Bluetooth device (e.g. a mobile phone).
Configuration Mode - the Blue LED blinks 1 time/sec. The device can accept commands
6 3 Green LED / Ext Red LED
The Green LED starts blinking when waiting for user to enter the PIN code.
The Green LED is solid on during door/gate activation else it is off.
The ext. Red LED is b default OFF (leave not connected). It can be controlled from external
controller through input 3 (Orange Core). The LED is set ON b pulling it down to GND.
6 4 Red LED / Ext Green LED
The Red LED is showing the status of the alarm/light control output. If Red LED is on the alarm is
armed/light is off. It goes off when alarm is disarmed/light is on.
The ext. Green LED is b default OFF (leave not connected). It can be controlled from external
controller through input 4 (Blue Core). The LED can be set ON b pulling it down to GND
All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010-07-06 US 1 17
Copyright © 2005-2010 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web www mvc-data com E-mail info@mvc-data com Phone +45 25 12 84 02
9/34
Dual LEDs

AccessZone ® - GC500 Series – GC501-GC504 User Manual
7 How to Configure the System
This section describes how to enter s stem commands and how to enable the s stem for
configuration. Section 8 S stem Commands describes the different commands in details.
7 1 Commands via Mobile
S stem configuration (adding/deleting users and changing s stem settings) can be done from an
Bluetooth enabled mobile phone as long as the user knows the 8 digit Master PIN code.
Note!
It is not necessar to install an software on the mobile phone or use an PC tool.
The mobile phone must support at least 20 characters as “Friendl Name” (also called "Phone
Name”). This is the name revealed for other Bluetooth devices.
A s stem command (e.g. "01,0022b4b62918,1234") is entered b temporaril changing the
mobiles Bluetooth “Friendl Name”. Refer to section 8 S stem Commands.
Please refer to the User Manual for a specific mobile phone for how to change the Bluetooth
friendl name.
Caution
The Bluetooth specification states a maximum length of 248 characters as Friendly Name.
However, most mobile phones have limited the space allowed for Friendly Name. A minimum of
20 characters must be supported by the used mobile phone.
All commands must be followed b the 8 digit Master PIN code for safe use. The s stem gives 3
short beeps to indicate that a valid command has been found and the Master PIN code is required.
The user will automaticall be prompted when to enter the Master PIN code.
Note!
This is not the normal 4 digit user access PIN code.
Please note when entering the commands:
All command parameters (enclosed by <>) must be separated by a comma ','
No spaces between values are allowed
Have the exact length as specified I e no additional characters in the end
A ‘-‘ indicates an integer range 1,2,3…
All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010-07-06 US 1 17
Copyright © 2005-2010 All rights reserved MVC-Data ApS Skalhuse 5 9240 Nibe Denmark Web www mvc-data com E-mail info@mvc-data com Phone +45 25 12 84 02
10/34
Dieses Handbuch passt für folgende Modelle
3
Inhaltsverzeichnis
Andere MVC-Data IP-Zugriffskontrollsysteme Handbücher