nal von minden Reactif Touch Bedienungsanleitung

new art laboratories
Reac f Touch
Manual
Rapid Tests
Laboratory Diagnos cs
Laboratory Service
Consul ng & Service

nal von minden GmbH · Manual
Reac f Touch

1
1
nal von minden GmbH
Carl-Zeiss-Strasse 12
47445 Moers
Germany
Friedenstrasse 32
93053 Regensburg
Germany
Tel.: +49 941 29010-0
Fax: +49 941 29010-50
info@nal-vonminden.com
www.nal-vonminden.com
Version 1.0
Januar 2017

nal von minden GmbH · Manual
Reac f Touch

Table of Contents
Sec on 1 Introduc on ........................................................................................................................................ 2
Intended Use.................................................................................................................................................. 2
Sec on 2 Analyzer Components.......................................................................................................................... 3
Port Func ons................................................................................................................................................ 5
Op onal Accessories...................................................................................................................................... 5
Sec on 3 Ini al Startup ...................................................................................................................................... 6
Plugging Analyzer In....................................................................................................................................... 6
Installing Ba eries (Op onal) ........................................................................................................................ 6
Interfacing to a Computer.............................................................................................................................. 7
Connec vity................................................................................................................................................... 7
Analyzer So ware Updates............................................................................................................................ 7
Loading the Printer Paper .............................................................................................................................. 7
Powering Up .................................................................................................................................................. 8
Powering Down.............................................................................................................................................. 8
Sec on 4 Touchscreen LCD Naviga on ................................................................................................................ 9
Sec on 5 Start-Up Wizard................................................................................................................................. 15
Sec on 6 Specimen Test ................................................................................................................................... 16
Entering the Canister Code .......................................................................................................................... 16
Specimen/Strip Prepara on ........................................................................................................................ 17
Strip Test - Quick Test................................................................................................................................... 17
Strip Test - Full Test ..................................................................................................................................... 22
Strip Test - Customized Test ........................................................................................................................ 23
Strip Test - Work List ................................................................................................................................... 23
Sec on 7 Analyzer Setup .................................................................................................................................. 29
Test Se ngs ................................................................................................................................................. 29
Analyzer Confi gura on ................................................................................................................................ 34
Setup Review ............................................................................................................................................... 40
Lockout ........................................................................................................................................................ 40
Diagnos c Tests ........................................................................................................................................... 48
Service ......................................................................................................................................................... 49
Sec on 8 Records Reviewg ............................................................................................................................... 50
Clear All Data ............................................................................................................................................... 50
Data Search.................................................................................................................................................. 50
Review All Data .......................................................................................................................................... 51
Sec on 9 QC Test.............................................................................................................................................. 53
QC Lockout................................................................................................................................................... 53
Strip Prepara on.......................................................................................................................................... 53
QC Test Procedures...................................................................................................................................... 53
Sec on 10 Cleaning and Maintenance .............................................................................................................. 57
Cleaning ....................................................................................................................................................... 57
Changing Ba eries....................................................................................................................................... 61
Touch Screen LCD Calibra on ...................................................................................................................... 62
Sec on 11 Troubleshoo ng .............................................................................................................................. 64
Appendix 1 Urine Analyzer Specifi ca ons ......................................................................................................... 68
Appendix 2 Performance Characteris cs of Urinalysis Reagent Strips................................................................ 69
Appendix 3 URS Parameter Table...................................................................................................................... 71
Appendix 4 Result Print-Out ............................................................................................................................. 73
Appendix 5 Barcode reader .............................................................................................................................. 75
Appendix 6 Safety Informa on ......................................................................................................................... 76
Appendix 7 Catalog........................................................................................................................................... 78
Appendix 8 Index of Symbols............................................................................................................................ 79
Appendix 9 Warranty........................................................................................................................................ 80

nal von minden GmbH · Manual
Reac f Touch
nal von minden GmbH · Manual
Reac f Touch
2nal von minden GmbH · Manual
Reac f Touch
Sec on 1 Introduc on
The Reac f Touch Urine Analyzer is a portable, easy to use analyzer. It is designed to read
only Reac f Urinalysis Reagent Strips.
The analyzer can be plugged into an electrical outlet and used on a bench top. It can also
be powered by ba eries to be able to freely move the analyzer from one tes ng site to
another.
The instrument performs a system test each me it is turned on. It automa cally calibrates
each me a test is run.
Results are displayed on the touchscreen and can be printed (if desired). The results can
also be transferred to a computer using an RS232 serial port or USB port on the back of the
instrument. The analyzer stores results from 2000 pa ent tests and is able to recall past
pa ent test results using the Records Review func on.
Note: Keys on the touchscreen are listed in bold. Display items on the screen and set-
ngs are listed in bold italics in this manual.
Note: Contains useful ps on using the analyzer.
Cau on: Should be followed carefully to ensure analyzer operates correctly and is
not damaged.
Intended Use
The Reac f Touch Urine Analyzer is intended for use in conjunc on with the Reac f
Urinalysis Reagent Strips for the semi-quan ta ve detec on of the following analytes in
urine: Glucose, Bilirubin, Ketone (Acetoace c acid), Specifi c Gravity, Blood, pH, Protein,
Urobilinogen, Nitrite, Leukocytes, Ascorbic Acid, Albumin, Crea nine, Calcium, Pro-
tein-to-Crea nine Ra o, and Albumin-to-Crea nine Ra o. The instrument is intended for
professional, in vitro diagnos c use only.
This Instruc on Manual contains direc ons to unpack the analyzer, for Reac f Urinalysis
Reagent Strip tes ng, and how to keep it in good working condi on. Throughout the
Operator’s Manual, these symbols can be seen:

3
Sec on 2 Analyzer Components
1. Analyzer
2. Power Cord and Supply Adapter
3. Printer Paper
4. Test Table
5. Test Table Insert

1. Printer Cover
2. LCD
3. Bu on
4. Printer Roller
5. Printer Paper
6. Printer
7. Test Table
8. Test Table Insert
9. SN Label
10. RS232-Port
11. USB Port 1
12. USB Port 2
13. DC Socket
14. SD card socket
15. Ba ery compartment
4nal von minden GmbH · Manual
Reac f Touch

Port Func ons
No. Port/ Socket Func on
10. RS232 Port Data transfer or Barcode reader or
External printer
11. USB Port 1 Data transfer
12. USB Port 2 So ware update or external printer
13. DC Socket DC adapter
14. SD card socket Install SD card for so ware update
15. Ba ery compartment Install 6 AA Alkaline ba eries
Op onal Accessories
1. RS232C Barcode Readerr
2. USB or RS232C Data Transfer Cable
3. Bluetooth adapter
4. Ethernet via USB to RJ45 Adapter
5. USB wireless net-card
6. SD card
7. USB Flash Drive
5

Sec on 3 Ini al Startup
Carefully remove the contents of the shipping carton. Check the carton and instrument
for visible signs of damage. If damaged, immediately contact the carrier. Remove wrap-
pings and check for all items (refer to Sec on 2 Analyzer components).
Place the instrument on a level work surface where temperature and humidity are fairly
constant.
Sec on 3 Ini al Startup
6nal von minden GmbH · Manual
Reac f Touch
Interfacing to a Computer
The instrument can send results to a computer via the serial port or the USB port located
Plugging Analyzer In
Plug the appropriate end of the power cord into the DC socket located on the back of
the analyzer. Plug the other end of the power cord into an AC electrical wall outlet.
Installing Ba eries (Op onal)
Place the analyzer on its side. Open the ba ery cover by sliding the tab away from the
cover. Place the 6 AA Alkaline ba eries into the analyzer. Close the ba ery cover and
turn the instrument back onto its base.
Cau on: Do not use the unit or the strips outside of the opera ng temperature
ranges listed below.
Analyzer: 0-40ºC (32-104ºF)
Strips: 15-30ºC (59-86ºF)
Do not place the analyzer outside or near windows, ovens, hot plates, or radiators.