Newport Electronics i Series Bedienungsanleitung

http://www.newportUS.com/i
®
NEWPORT
Electronics, Inc.
Process / Strain Gauge
Monitor / Alarm
Operator’s Manual

Counters
Frequency Meters
PID Controllers
Clock/Timers
Printers
Process Meters
On/Off
Controllers
Recorders
Relative
Humidity
Transmitters
Thermocou les
Thermistors
Wire
Rate Meters
Timers
Totalizers
Strain Gauge
Meters
Voltmeters
Multimeters
Soldering Iron
Testers
H ens
H Controllers
H Electrodes
RTDs
Thermowells
Flow Sensors
For Immediate Assistance
In the U.S.A. and Canada: 1-800-NEWPORT
®
In Mexico: (95) 800-NEWPORT
SM
Or call your local NEWPORT Office.
Internet e-mail
info@new ortUS.com
Additional roducts from
N WPORTnetSM On-Line Service
www.new ortUS.com
®
NEWPORT
Electronics, Inc.
It is the olicy of NEWPORT to com ly with all worldwide safety and EMC/EMI regulations that a ly. NEWPORT is constantly
ursuing certification of its roducts to the Euro ean New A roach Directives. NEWPORT will add the CE mark to every
a ro riate device u on certification.
The information contained in this document is believed to be correct but NEWPORT Electronics, Inc. acce ts no liability for any
errors it contains, and reserves the right to alter s ecifications without notice.
WARNING: These roducts are not designed for use in, and should not be used for, atient connected a lications.
TRADEMARK NOTICE:
, NEWPORT, NEWPORT
®
, newportUS.com and the “Meter Bezel Design” are
trademarks of NEWPORT Electronics, Inc.
PATENT NOTICE: This roduct is covered by one or more of the following atents: U.S. Pat. No. Des. 336,895; 5,274,577;
6,243,021 / CANADA 2052599; 2052600/ ITALY 1249456; 1250938 / FRANCE BREVET No. 91 12756 / SPAIN 2039150;
2048066 / UK PATENT No. GB2 249 837; GB2 248 954 / GERMANY DE 41 34398 C2. The ™is a Trademark of OMEGA
Engineering, Inc. Used Under License. Other US and International Patents ending or a lied for.
This device is marked with the international caution symbol. It is im ortant to read the Setu Guide before installing or
commissioning this device as it contains im ortant information relating to safety and EMC.

TABLE OF CONTENTS
Part 1: Introduction............................................................................................2
1.1 Description .................................................................................2
1.2 Safety Considerations ...............................................................3
1.3 Before You Begin .......................................................................4
Part 2: Setup.......................................................................................................5
2.1 Front Panel .................................................................................5
2.2 Rear Panel Connections............................................................5
2.3 lectrical Installation .................................................................7
2.3.1 Power Connections........................................................7
2.3.2 Process Current .............................................................8
2.3.3 Process Voltage..............................................................8
2.3.4 Strain Gauge ...................................................................9
2.3.5 Wiring Outputs .............................................................10
Part 3: Operation: Configuration Mode .........................................................12
3.1 Introduction ..............................................................................12
Turning your Instrument On for the First Time
Buttons Functions in Configuration Mode
3.2 Menu Configuration ................................................................13
3.2.1 ID Number .....................................................................14
3.2.2 Set Points Menu ...........................................................15
3.2.3 Configuration Menu ....................................................16
3.2.4 Input Type Menu ...........................................................16
3.2.5 Reading Configuration Menu .....................................18
3.2.6 Input/Reading (Scale and Offset) Menu ....................21
3.2.7 Alarm 1 Menu................................................................25
3.2.8 Alarm 2 Menu................................................................29
3.2.9 Setpoint Deviation Menu .............................................30
3.2.10 ID Code Menu ...............................................................31
3.2.11 Communication Option Menu .....................................33
3.2.12 Display Color Selection Menu.....................................40
Part 4: Specifications ......................................................................................43
Part 5: Factory Preset Values .........................................................................45
C APPROVAL INFORMATION .......................................................................47
i

LIST OF FIGURES:
Figure 2.1 Front Panel Display .....................................................................5
Figure 2.2 Rear Panel Power Connections .................................................5
Figure 2.3 Rear Panel Input Connections ...................................................6
Figure 2.4 Main Power Connections............................................................7
Figure 2.5 Process Current Wiring Hookup ................................................8
Process Voltage
Figure 2.6 a) Process Voltage with Sensor xcitation ...........................8
b) Process Voltage without Sensor xcitation .....................8
Strain Gauge
Figure 2.7 a) 4-Wire Voltage Input with Internal xcitation....................9
b) 4-Wire Bridge Input with xternal xcitation....................9
Figure 2.8 a) 6-Wire Voltage Input with Internal xcitation....................9
b) 6-Wire Bridge Input with xternal xcitation....................9
Figure 2.9 4-Wire Voltage Input with Internal xcitation.......................10
Figure 2.10 a) Mechanical Relay and SSR Outputs Wiring Hookup .....10
b) Pulse and Analog Outputs Wiring Hookup .....................10
Figure 2.11 a) RS-232 Output Wiring Hookup .........................................11
b) RS-485 Output Wiring Hookup .........................................11
Figure 2.12 a) xcitation Output...............................................................11
b) Top View Location of S2 ...................................................11
c) Top View Location of S2 on 1/8DIN Compact Unit ..........11
Figure 3.1 Flow Chart for ID and Setpoints Menu ....................................13
Figure 3.2 Flow Chart for Configuration Menu .........................................16
Figure 3.3 Flow Chart for Input Type Menu ...............................................16
Figure 3.4 Flow Chart for Reading Configuration Menu ..........................18
Figure 3.5 Flow Chart for Alarm 1 Menu....................................................25
Figure 3.6 Flow Chart for Alarm 2 Menu....................................................29
Figure 3.7 Flow Chart for Setpoint Deviation Menu .................................30
Figure 3.8 Flow Chart for ID Code Menu ...................................................31
Figure 3.9 Flow Chart for Communication Option Menu .........................33
Figure 3.10 Flow Chart for Display Color Selection Menu.........................40
LIST OF TABLES:
Table 2.1 Front Panel Display .....................................................................5
Table 2.2 Rear Panel Connector .................................................................6
Table 2.3 Power Connections .....................................................................7
Table 2.4 Jumper Connections .................................................................11
Table 3.1 Button Function in Configuration Mode..................................12
Table 3.2 Conversion Table.......................................................................22
Table 3.3 Input Resolution Multiplier .......................................................22
Table 5.1 Factory Preset Values ...............................................................45
ii

NOTES, WARNINGS and CAUTIONS
Information that is es ecially im ortant to note is identified by following labels:
• NOT
• WARNING or CAUTION
• IMPORTANT
• TIP
NOT : Provides you with information that is im ortant to successfully
setu and use the Programmable Digital Meter.
CAUTION or WARNING: Tells you about the risk of electrical shock.
CAUTION, WARNING or IMPORTANT: Tells you of circumstances or
ractices that can effect the instrument’s functionality and must refer to
accom anying documents.
TIP: Provides you hel ful hints.
1

PART 1
INTRODUCTION
1.1 Description
This device can be urchased as monitor (read rocess value only) or as
a controller.
• The iSeries Strain and Process monitors can measure a wide variety of DC
voltage and current in uts for all common load cells, ressure transducers
and strain gauge ty e of transducer. The voltage /current in uts are fully
scaleable to virtually all engineering units, with selectable decimal oint,
erfect for use with ressure, flow or other rocess in ut.
•
The iSeries monitor features a large, three color rogrammable dis lay with
ca ability to change a color every time when Alarm is triggered. The standard
features include built-in excitation for transducers, selectable as 10V @ 60 mA
or 5 V @ 40 mA. (Built-in excitation is not available with o tional isolated
RS-232/485 Serial Communication). Universal ower su ly acce ts 90 to
240. Low voltage ower o tion acce ts 24 VAC or 12 to 36 VDC.
2

1.2 Safety Considerations
This device is marked with the international caution symbol. It is
important to read this manual before installing or commissioning this
device as it contains im ortant information relating to Safety and MC
(Electromagnetic Com atibility).
This instrument is a panel mount device rotected in accordance with
Class II of EN 61010 (115/230 ac ower connections), Class III for the
low voltage ower o tion (12 - 36 Vdc or 24 Vac). Installation of this
instrument should be done by a qualified ersonnel. In order to ensure
safe o eration, the following instructions should be followed.
This instrument has no power-on switch. An external switch or circuit-
breaker shall be included in the building installation as a disconnecting
device. It shall be marked to indicate this function, and it shall be in close
roximity to the equi ment within easy reach of the o erator. The switch
or circuit-breaker shall not interru t the Protective Conductor (Earth wire),
and it shall meet the relevant requirements of IEC 947–1 and IEC 947-3
(International Electrotechnical Commission). The switch shall not be
incor orated in the main su ly cord.
Furthermore, to rovide rotection against excessive energy being
drawn from the main su ly in case of a fault in the equi ment, an
overcurrent rotection device shall be installed.
• Do not exceed voltage rating on the label located on the to of the
instrument housing.
• Always disconnect ower before changing signal and ower
connections.
• Do not use this instrument on a work bench without its case for safety
reasons.
• Do not o erate this instrument in flammable or ex losive
atmos heres.
• Do not ex ose this instrument to rain or moisture.
• Unit mounting should allow for adequate ventilation to ensure
instrument does not exceed o erating tem erature rating.
• Use electrical wires with adequate size to handle mechanical strain
and ower requirements. Install without ex osing bare wire outside
the connector to minimize electrical shock hazards.
MC Considerations
• Whenever EMC is an issue, always use shielded cables.
• Never run signal and ower wires in the same conduit.
• Use signal wire connections with twisted- air cables.
• Install Ferrite Bead(s) on signal wires close to the instrument if EMC
roblems ersist.
Failure to follow all instructions and warnings may result in injury!
3

1.3 Before You Begin
Inspecting Your Shipment:
Remove the acking sli and verify that you have received everything
listed. Ins ect the container and equi ment for signs of damage as soon
as you receive the shi ment. Note any evidence of rough handling in
transit. Immediately re ort any damage to the shi ing agent. The carrier
will not honor damage claims unless all shi ing material is saved for
ins ection. After examining and removing the contents, save the acking
material and carton in the event reshi ment is necessary.
Customer Service:
If you need assistance, lease call the nearest Customer Service
De artment, listed in this manual.
Manuals, Software:
The latest O eration and Communication Manual as well as free software
and ActiveX controls are available at the website listed on the cover
page of this manual or on the CD-ROM enclosed with your
shipment.
To Reset the Meter:
When the monitor is in the "MENU" Mode, push conce to direct monitor
one ste backward of the to menu item.
Push ctwice to reset monitor, rior to resuming "Run" Mode exce t
after "Alarms", that will go to the "Run" Mode without resetting the
monitor.
4

PART 2
SETUP
2.1 Front Panel
Figure 2.1 Front Panel Display
Table 2.1 Front Panel Annunciators
1Set oint 1/ Alarm 1 indicator
2Set oint 2/ Alarm 2 indicator
a/MENU Changes dis lay to Configuration Mode and advances
through menu items*
b/PK/GRS Used in Program Mode and Peak or Gross Recall*
c/TARE Used in Program Mode and to tare your reading*
d/ENTER Accesses submenus in Configuration Mode and stores
selected values*
* See Part 3 O eration: Configuration Mode
2.2 Rear Panel Connections
The rear anel connections are shown in Figures 2.2 and 2.3.
Figure 2.2 Rear Panel Power Connections
MENU PK/GRS TARE ENTER MENU PK/GRS TARE ENTER MENU PK/GRS TARE ENTER
5

Figure 2.3 Rear Panel Input Connections
Table 2.2 Rear Panel Connector
POW R AC/DC Power Connector: All models
INPUT In ut Connector:
All models PR (Process) / ST (Strain)
OUTPUT 1 Based on one of the following models:
Relay SPDT
Solid State Relay
Pulse
OUTPUT 2 Based on one of the following models:
Relay SPDT
Solid State Relay
Pulse
OPTION Based on one of the following models:
RS-232C or RS-485 rogrammable
Excitation
Out ut 1 and 2 are for -AL Alarm O tion only.
6
Andere Handbücher für i Series
3
Inhaltsverzeichnis
Andere Newport Electronics Messgerät Handbücher

Newport Electronics
Newport Electronics 204B Bedienungsanleitung

Newport Electronics
Newport Electronics 215-2 Bedienungsanleitung

Newport Electronics
Newport Electronics INFINITY Series Bedienungsanleitung

Newport Electronics
Newport Electronics wi Series Bedienungsanleitung

Newport Electronics
Newport Electronics 558B Bedienungsanleitung

Newport Electronics
Newport Electronics INFCP-B Series Bedienungsanleitung

Newport Electronics
Newport Electronics INFINITY INFCDT Bedienungsanleitung

Newport Electronics
Newport Electronics IDP INFINITY D Bedienungsanleitung