Particulate Systems MA-1040 Bedienungsanleitung

MA-1040
Magnetic Analyzer
Operator’s Manual
V2.0
P03-42801-00
March 2011

© Particulate Systems 2011. All rights reserved. Printed in the U.S.A.

WARRANTY
Particulate Systems, a brand operating under MICROMERITICS INSTRUMENT CORPORATION, warrants
for one year from the date of shipment each instrument it distributes to be free from defects in material and
workmanship impairing its usefulness under normal use and service conditions except as noted herein.
Our liability under this warranty is limited to repair, servicing and adjustment, free of charge at our plant, of any
instrument or defective parts when returned prepaid to us and which our examination discloses to have been
defective. The purchaser is responsible for all transportation charges involving the shipment of materials for
warranty repairs. Failure of any instrument or product due to operator error, improper installation, unauthorized
repair or alteration, failure of utilities, or environmental contamination will not constitute a warranty claim. The
materials of construction used in products distributed by MICROMERITICS under the Particulate Systems
brand cannot be totally guaranteed against wear and/or decomposition by chemical action (corrosion) as a result
of normal use.
Repair parts are warranted to be free from defects in material and workmanship for 90 days from the date of
shipment.
No instrument or product shall be returned to MICROMERITICS prior to notification of alleged defect and
authorization to return the instrument or product. All repairs or replacements are made subject to factory inspec-
tion of returned parts. MICROMERITICS shall be released from all obligations under its warranty in the event
repairs or modifications are made by persons other than its own authorized service personnel unless such work
is authorized in writing by MICROMERITICS.
The obligations of this warranty will be limited under the following conditions:
1. Certain products sold by MICROMERITICS are the products of reputable manufacturers, sold under their
respective brand names or trade names. We, therefore, make no express or implied warranty as to such
products. We shall use our best efforts to obtain from the manufacturer, in accordance with his customary
practice, the repair or replacement of such of his products that may prove defective in workmanship or
materials. Service charges made by such manufacturer are the responsibility of the ultimate purchaser. This
states our entire liability in respect to such products, except as an authorized person of MICROMERITICS
may otherwise agree to in writing.
2. If an instrument or product is found defective during the warranty period, replacement parts may, at the dis-
cretion of MICROMERITICS, be sent to be installed by the purchaser, e.g., printed circuit boards, check
valves, seals, etc.
3. Expendable items, e.g., sample tubes, detector source lamps, indicator lamps, fuses, valve plugs (rotor) and
stems, seals and O-rings, ferrules, etc., are excluded from this warranty except for manufacturing defects.
Such items which perform satisfactorily during the first 45 days after the date of shipment are assumed to
be free of manufacturing defects.
Purchaser agrees to hold MICROMERITICS harmless from any patent infringement action brought against
MICROMERITICS if, at the request of the purchaser, MICROMERITICS modifies a standard product or man-
ufactures a special product to the purchaser’s specifications.
MICROMERITICS shall not be liable for consequential or other type damages resulting from the use of any of
its products other than the liability stated above. This warranty is in lieu of all other warranties, express or
implied, including, but not limited to, the implied warranties of merchantability or fitness for use.
4356 Communications Drive, Norcross, GA 30093
Fax (770) 662-3696
Domestic Sales - (770) 662-3633
Domestic Repair Service - (770) 662-3666
International Sales - (770) 662-3660
Customer Service - (770) 662-3636


MA-1040 Magnetic Analyzer TableofContents
Mar 2011 i
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Components and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Top Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Side Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Setting up the Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Reference Standard Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Cleaning the Sample Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Weighing the Sample. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Performing the Analysis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9


MA-1040 Magnetic Analyzer Introduction
May 2011 1
Introduction
This operator’s manual provides a description, specifications, and operating instructions for the
MA-1040 Magnetic Analyzer.
The following symbols are used to identify notes of importance and cautions.
Description
The MA-1040 Magnetic Analyzer is designed to detect very low levels of magnetic materials. It is
capable of measuring magnetic content down to 0.1 parts-per-million (ppm) resolution.
The MA-1040 is useful for detecting minute quantities of iron or other ferromagnetic elements in a
wide range of materials such as high-purity glass used for fiber optics or plastics used in wiring insula-
tion. The MA-1040 can also be used to detect low magnetic iron levels in food, precious gems,
pharmaceuticals, and many other materials. The MA-1040 has been referenced in American National
Standards Institute ( ANSI ) bulletins as well as bulletins for the Abrasive Grain Association.
All of the MA-1040 Magnetic Analyzer components are enclosed in a small cabinet. The controls are
located on top of the enclosure for easy visibility and convenient access. The power switch and the
serial port are mounted on the side.
Operation is simple and straight-forward. A sample, the weight of which has been entered, is lowered
into the sample chamber and, within in secords, a digital readout displays the results.
Notes contain important information pertinent to the subject matter.
Cautions contain information to prevent damage to the analyzer or its
components.

Description MA-1040 Magnetic Analyzer
2May 2011
Components and Connectors
Top Panel
.
LCD Five-Digit Display Displays readings of magnetic content in PPM
WEIGHT-GRAMS
control Used to enter the sample weight
Range: 000 - 999 grams
ZERO control Used to zero the reading on the display when the sample chamber
is empty
Sample Chamber For inserting the sample holder or reference standard
Five-Digit Display
Sample Chamber
WEIGHT-GRAMS
ZERO
Control Control

MA-1040 Magnetic Analyzer Description
May 2011 3
Side Panel
Power connector For connecting the power cord
On/Off switch For turning the analyzer on and off
Power
connector On/Off switch

Specifications MA-1040 Magnetic Analyzer
4May 2011
Specifications
Characteristic Specification
Environment
Temperature: Stable between 10 and 45 ºC (50 to 113 ºF), operating;
-10 and 55 ºC (14 to 131 ºF), non-operating
Physical
Height: 16.76 cm (6.6 in.)
Width: 25.40 cm (10 in.)
Depth: 13.34 cm (5.25 in.)
Weight: 6.8 kg (15 lbs)
Electrical
Voltage: 95 - 250 VAC
Frequency: 50 to 60 Hz
Sample
Sample weight: 000 - 999 grams
Magnetic content: 0.1 ppm - 1999.9 ppm