PR 5715 Bedienungsanleitung

5715
SIGNALS THE BEST
Programmable
LED Indicator
No. 5715V102-UK
From serial number:
121496001 (B)
131077001 (D)

1318
PR electronics A/S tilbyder et bredt program af analoge og digitale
signalbehandlingsmoduler til industriel automation. Programmet
består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere,
Universaltransmittere m. Vi har modulerne, du kan stole på i selv
barske miljøer med elektrisk støj, vibrationer og temperaturud-
sving, og alle produkter opfylder de strengeste internationale stan-
darder. Vores motto »Signals the Best« er indbegrebet af denne
loso – og din garanti for kvalitet.
PR electronics A/S offers a wide range of analogue and digital
signal conditioning devices for industrial automation. The product
range includes Isolators, Displays, Ex Interfaces, Temperature
Transmitters, and Universal Devices. You can trust our products
in the most extreme environments with electrical noise, vibrations
and temperature uctuations, and all products comply with the
most exacting international standards. »Signals the Best« is the
epitome of our philosophy – and your guarantee for quality.
PR electronics A/S offre une large gamme de produits pour le
traitement des signaux analogiques et numériques dans tous
les domaines industriels. La gamme de produits s’étend des
transmetteurs de température aux afcheurs, des isolateurs aux
interfaces SI, jusqu’aux modules universels. Vous pouvez compter
sur nos produits même dans les conditions d’utilisation sévères,
p.ex. bruit électrique, vibrations et uctuations de température.
Tous nos produits sont conformes aux normes internationales les
plus strictes. Notre devise »SIGNALS the BEST« c’est notre ligne
de conduite - et pour vous l’assurance de la meilleure qualité.
PR electronics A/S verfügt über ein breites Produktprogramm
an analogen und digitalen Signalverarbeitungsgeräte für die in-
dustrielle Automatisierung. Dieses Programm umfasst Displays,
Temperaturtransmitter, Ex- und galvanische Signaltrenner, und
Universalgeräte. Sie können unsere Geräte auch unter extremen
Einsatzbedingungen wie elektrisches Rauschen, Erschütterungen
und Temperaturschwingungen vertrauen, und alle Produkte von
PR electronics werden in Übereinstimmung mit den strengsten
internationalen Normen produziert. »Signals the Best« ist Ihre
Garantie für Qualität!
DK
UK
FR
DE

5715V102-UK 1
PROGRAMMABLE LED INDICATOR
5715
CONTENTS
Warning .............................................................................. 2
Symbol identification.......................................................... 2
Safety instructions.............................................................. 3
Declaration of conformity................................................... 5
Front and back layout ........................................................ 6
Application ......................................................................... 7
Technical characteristics.................................................... 7
Mounting / installation........................................................ 7
Applications........................................................................ 8
Order: 5715 ........................................................................ 9
Electrical specifications...................................................... 9
Sensor error detection inside and outside range............... 13
Connections ....................................................................... 14
Block diagram .................................................................... 15
Routing diagram................................................................. 17
Scrolling help texts............................................................. 18
Configuration / operating the function keys ...................... 20
Programming via PC .......................................................... 21
Graphic depiction of the relay function setpoint................ 21

2 5715V102-UK
SYMBOL IDENTIFICATION
Triangle with an exclamation mark: Warning / demand. Potentially
lethal situations.
The CE mark proves the compliance of the module with the essential
requirements of the directives.
WARNING
This module is designed for connection to hazardous electric
voltages. Ignoring this warning can result in severe personal
injury or mechanical damage. To avoid the risk of electric shock
and fire, the safety instructions of this manual must be observed
and the guidelines followed. The specifications must not be
exceeded, and the module must only be applied as described
in the following. Prior to the commissioning of the module, this
manual must be examined carefully. Only qualified personnel
(technicians) should install this module.
If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may be
impaired.
WARNING
Until the module is fixed, do not connect hazardous voltages to
the module.
The following operations should only be carried out on a
disconnected module and under ESD safe conditions:
Troubleshooting the module.
Repair of the module must be done by PR electronics A/S
only.
HAZARD-
OUS
VOLTAGE
GENERAL

5715V102-UK 3
SAFETY INSTRUCTIONS
DEFINITIONS
Hazardous voltages have been defined as the ranges: 75 to 1500 Volt DC, and
50 to 1000 Volt AC.
Technicians are qualified persons educated or trained to mount, operate, and
also troubleshoot technically correct and in accordance with safety regulations.
Operators, being familiar with the contents of this manual, adjust and operate
the knobs or potentiometers during normal operation.
RECEIPT AND UNPACKING
Unpack the device without damaging it. The packing should always follow the
device until this has been permanently mounted. Check at the receipt of the
device whether the type corresponds to the one ordered.
ENVIRONMENT
Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock,
as well as rain and heavy moisture. If necessary, heating in excess of the stated
limits for ambient temperatures should be avoided by way of ventilation.
All modules fall under Installation Category II, Pollution Degree 1, and Insulation
Class II.
MOUNTING
Only technicians who are familiar with the technical terms, warnings, and
instructions in the manual and who are able to follow these should connect the
module.
Should there be any doubt as to the correct handling of the module, please
contact your local distributor or, alternatively,
PR electronics A/S
www.prelectronics.com
Mounting and connection of the module should comply with national legislation
for mounting of electric materials, i.e. wire cross section, protective fuse, and
location. Descriptions of Input / Output and supply connections are shown in
the block diagram and side label.

4 5715V102-UK
The following apply to fixed hazardous voltages-connected modules:
The max. size of the protective fuse is 10 A and, together with a power
switch, it should be easily accessible and close to the module. The
power switch should be marked with a label telling it will switch off the
voltage to the module.
UL INSTALLATION REQUIREMENTS
For use on a flat surface of a type 1 enclosure
Use 60/75°C copper conducters only
Enclosure rating (face only).................... Type 4X, UL50E
Max. ambient temperature..................... 60°C
Max. wire size, pins 41...46.................... AWG 30-16
Max. wire size, others ............................ AWG 30-12
UL file number........................................ E248256
CALIBRATION AND ADJUSTMENT
During calibration and adjustment, the measuring and connection of external
voltages must be carried out according to the specifications of this manual. The
technician must use tools and instruments that are safe to use.
NORMAL OPERATION
Operators are only allowed to adjust and operate modules that are safely fixed
in panels, etc., thus avoiding the danger of personal injury and damage. This
means there is no electrical shock hazard, and the module is easily accessible.
CLEANING
When disconnected, the module may be cleaned with a cloth moistened with
distilled water.
LIABILITY
To the extent the instructions in this manual are not strictly observed, the
customer cannot advance a demand against PR electronics A/S that would
otherwise exist according to the concluded sales agreement.

5715V102-UK 5
DECLARATION OF CONFORMITY
As manufacturer
PR electronics A/S
Lerbakken 10
DK-8410 Rønde
hereby declares that the following product:
Type: 5715
Name: Programmable LED indicator
is in conformity with the following directives and standards:
The EMC Directive 2004/108/EC and later amendments
EN 61326-1
For specification of the acceptable EMC performance level, refer to the
electrical specifications for the module.
The Low Voltage Directive 2006/95/EC and later amendments
EN 61010-1
Rønde, 17 December 2009 Kim Rasmussen
Manufacturer’s signature

6 5715V102-UK
FRONT AND BACK LAYOUT
Picure 1: Front of PReview 5715.
Picture 2: Back of PReview 5715.

5715V102-UK 7
PROGRAMMABLE LED INDICATOR
PREVIEW 5715
• 4-digit 14-segment LED display
• Input for mA, V, potentiometer, Ohm, RTD and TC
• 4 relays and analogue output
• Universal supply
• Programmable via front keys and PC
Application
• Displayfordigitalreadoutofcurrent/voltage/resistance/temperatureor
3-wire potentiometer signals.
• Processcontrolwith4pairsofpotential-freechange-overrelaysand
analogue output.
• Fortanklevelcontrol,withthepossibilityofcustomerlinearisationensuring
correct level measurement and control in non-linear tanks.
Technical characteristics
• 4-digitLEDindicatorwith13.8mm14-segmentcharacters.Max.display
readout -1999...9999 with programmable decimal point and relay ON / OFF
indication.
• Allstandardoperationalparameterscanbeadjustedtoanyapplicationby
way of the front function keys. When programming is carried out by way of
a PC and the configuration program PReset, additional configuration options
are available, such as customer-defined linearisation and special input signals.
• Helptextsineightlanguagescanbeselectedviaamenuitem.
• Amenuitemallowstheusertominimisetheinstallationtesttimefortherelay
outputs by activating/deactivating each relay independently of the input signal.
Mounting / installation
• Tobemountedinpanelfront.Theincludedrubberpackingmustbemounted
between the panel cutout hole and the display front to obtain a protection
degree of IP65 (type 4X). For extra protection in extreme environments,
PReview 5715 can be delivered with a specially designed splash-proof cover
as accessory.

46
45
44
43
42
41
4 3 2
1 2 3 4
1 2 3 4 12
11
26
25
24
23
22
21
66
65
64
63
62
61
32
31
1 2 3 4
-
+
-
+
-
+
-
+
-
+
8 5715V102-UK
APPLICATIONS
Input signals:
Current
Potentio-
meter
Output signals:
4 change-over relays
Analogue, 0/4...20 mA
Supply:
21.6...253 VAC
or
19.2...300 VDC
Voltage
RTD & Lin R -
Connection, wires
2-twire transmitter
TC
Inhaltsverzeichnis
Andere PR Messgerät Handbücher