ProLights Astra Beam260IP Bedienungsanleitung

USER MANUAL
REV.01-03/21 English version
Astra Beam260IP
IP65 moving beam light with 260 W PRO
long life lamp (6.000 hours)

Thank you for choosing PROLIGHTS
Please note that every PROLIGHTS product has been designed in Italy to meet quality and performance requirements
for professionals and designed and manufactured for the use and application as shown in this document.
Any other use, if not expressly indicated, could compromise the good condition/operation of the product and/or be
a source of danger.
This product is meant for professional use. Therefore, commercial use of this equipment is subject to the respectively
applicable national accident prevention rules and regulations.
Features, specications and appearance are subject to change without notice. Music & Lights S.r.l. and all afliated
companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other
loss occasioned by the use of, inability to use or reliance on the information contained in this document.
Product user manual can be downloaded from the website www.prolights.it , or can be inquired to the ofcial
PROLIGHTS distributors of your territory (https://www.prolights.it/sales_network.html).
Scanning the below QR Code, you will access the download area of the product page, where you can nd a broad
set of always updated technical documentation: specications, user manual, technical drawings, photometrics,
personalities, xture rmware updates.
The PROLIGHTS Logo, PROLIGHTS names and all other trademark in this document pertaining to PROLIGHTS services
or PROLIGHTS product are trademarks OWNED or licensed by Music & Lights S.r.l., its afliates, and subsidiaries.
PROLIGHTS is a registered trademark by Music & Lights S.r.l. All right reserved. Music & Lights – Via A. Olivetti, snc -
04026 - Minturno (LT) ITALY.
Visit the download area
of the product page

PROLIGHTS - Astra Beam260IP 01
INDEX
SAFETY INFORMATION 02
1 - PACKAGING 05
PACKAGE CONTENT..................................................................................................... 05
OPTIONAL ACCESSORIES............................................................................................. 05
2 - TECHNICAL DRAWING 05
3 - PAN AND TILT LOCK 06
4 - INSTALLATION 07
MOUNTING.................................................................................................................... 07
5 - CONNECTION TO THE MAINS SUPPLY 08
6 - START UP 08
CONNECT AND DISCONNECT POWER FROM THE PRODUCT.................................. 08
7 - PRODUCT OVERVIEW 09
8 - DMX CONNECTION 10
CONNECTION OF THE CONTROL SIGNAL: DMX LINE .............................................. 10
INSTRUCTIONS FOR A RELIABLE DMX CONNECTION ............................................... 10
CONNECTION DAISY CHAIN........................................................................................ 10
CONNECTION OF THE DMX LINE................................................................................ 10
CONSTRUCTION OF THE DMX TERMINATION ........................................................... 11
DMX ADDRESSING ........................................................................................................ 11
ETHERNET CONNECTION ............................................................................................ 11
ETHERNET OPERATION ................................................................................................ 11
ETHERNET TO DMX OPERATIONS ............................................................................... 12
OPERATION AS A WIRELESS TRANSMITTER................................................................ 12
IN TO WDMX ................................................................................................................. 12
OPERATION AS A WIRELESS RECEIVER........................................................................ 13
WDMX TO DMX (RX)...................................................................................................... 13
9 - CONTROL PANEL 14
DISPLAY AND BUTTONS LAYOUT................................................................................. 14
10 - MENU STRUCTURE 15
11 - SHORTCUT 18
12 - RDM FUNCTIONS 19
13 - DMX CHARTS 21
14 - GOBOS WHEEL 25
15 - COLOR WHEEL 26
16 - LAMP REPLACEMENT 27
CENTERING SYSTEM OF THE LAMP............................................................................. 30
17 - ERROR MESSAGES 31
18 - PERIODICAL CLEANING 34
19 - TEST OF THE RATED IP65 37
20 - MAINTENANCE 39
MAINTENANCE AND CLEANING THE PRODUCT........................................................ 39
REPLACING THE FUSE................................................................................................... 39
VISUAL CHECK OF PRODUCT HOUSING ..................................................................... 39
TROUBLESHOOTING..................................................................................................... 40

PROLIGHTS - Astra Beam260IP02
SAFETY INFORMATION
WARNING!
• Please read carefully the instruction reported in this section before installing, power-
ing, operating or servicing the product and observe the indications also for its future
handling.
This unit is not for household use, only professional applications.
Connection to mains supply
• The Connection to the mains supply must be carried out by a qualied electrical
installer.
• Use only AC supplies 100-240V 50-60 Hz, the xture must be electrically connected
to ground (earth).
• Select the cable cross section in according with the maximum current draw of the
product and the possible number of products connected at the same power line.
• The AC mains power distribution circuit must be equipped with magnetic+residual
current circuit breaker protection.
• Do not connect it to a dimmer system; doing so may damage the product.
Protection and Warning against electrical shock
• Do not remove any cover from the product, always disconnect the product from AC
power before servicing.
• Ensure that the xture is electrically connected to ground (earth). And use only a
source of AC power that complies with local building and electrical codes and has
both overload and ground-fault (earth-fault) protection.
• Before using the xture, check that all power distribution equipment and cables are
in perfect condition and rated for the current requirements of all connected devices.
• Isolate the xture from power immediately if the power plug or any seal, cover, ca-
ble, or other components are damaged, defective, deformed or showing signs of
overheating.
• Do not reapply power until repairs have been completed.
• Refer any service operation not described in this manual to PROLIGHTS Service team
or an authorized PROLIGHTS service center.
Installation
• Make sure that all visible parts of the product are in good visible condition before its
use or installation.
• Make sure the point of anchorage is stable before positioning the projector.
• When suspending the xture above ground level, secure it against failure of primary
attachments by attaching a safety cable that is approved as a safety attachment for
the weight of the xture to the attachment point on the main frame of the product. ln
case the safety cable, enter in action, it needs to be replaced with a new one.
• Install the product only in well ventilated places.
• For non temporary installations, ensure that the xture is securely fastened to a load-
bearing surface with suitable corrosionresistant hardware.
• For a temporary installation with clamps, ensure that the quarter-turn fastener and/or
screws are turned fully, and secured with a suitable safety cable.
15 m Minimum distance of illuminated objects
• The projector needs to be positioned so that the objects hit by the beam of light are
at least 15 meters (49.21 ft) from the lens of the projector.

PROLIGHTS - Astra Beam260IP 03
T 40°C
a
Max operating ambient temperature (Ta)
• Do not operate the xture if the ambient temperature (Ta) exceeds 40 °C (104 °F).
T
-15°
C
a
Minimum operating ambient temperature (Ta)
• Do not operate the xture if the ambient temperature (Ta) is below -15 °C (5 °F).
Protection from burns and re
• The exterior of the xture becomes hot during use. Avoid contact by persons and
materials.
• Ensure that there is free and unobstructed airow around the xture.
• Keep ammable materials well away from the xture
• Do not expose the front glass to sunlight or any other strong light source from any an-
gle. Lenses can focus the sun’s rays inside the xture, creating a potential re hazard.
• Do not attempt to bypass thermostatic switches or fuses.
IP65
Outdoor (temporary) use
• This product is rated with an IP (Ingress protection) for temporary outdoor use when
used and serviced according to the instruction contained in this document.
• Never use the xture in places subject to vibrations or bumps.
• Make certain that no inammable liquids, water or metal objects enter the xture.
• Excessive dust, smoke uid, and particle build up degrades performance, causes
overheating and will damage the xture.
• Damages caused by inadequate cleaning or maintenance are not covered by the
product warranty
Light collimation optical system*
• This product contains internal light collimation opticsl system. Avoid to expose the
optical system to any intense source of light (including sunlight) from any angle.
T
85°
C
c
Temperature of the external surface
• The surface of the xture can reach up to 85 °C (185 °F) during operation. Avoid
contact with people and materials.
Lamp*
The tting mounts a high-pressure lamp that needs an external ignitor. This ignitor is
tted onto the apparatus.
1. Carefully read the “operating instructions” provided by the lamp and ignitor manufacturer.
2. Immediately replace the lamp if damaged or deformed by heat.
Photobiological safety
• This device emits potentially dangerous optical radiation and is identied in the cat-
egory of Risk Group 1 according to EN 62471.
Radio receiver*
• This product contains a radio receiver and/or transmitter:
• Maximum output power: 17 dBm.
• Frequency band: 2.4 GHz.

PROLIGHTS - Astra Beam260IP04
Maintenance
• Warning! Disconnect the xture from AC mains power and allow to cool for at least
10 minutes before handling.
• Only technicians who are authorized by PROLIGHTS or Authorised service partners
are permitted to open the xture.
• Users may carry out external cleaning, following the warnings and instructions pro-
vided, but any service operation not described in this manual must be referred to a
qualied service technician.
• Important! Excessive dust, smoke uid, and particle build up degrades performance,
causes overheating and will damage the xture. Damages caused by inadequate
cleaning or maintenance is not covered by the product warranty.
Do not stare at the operating light source
• Do not look directly at the source during operation. It can be harmful to the eyes
and skin.
• During Installation, operation and maintenance, be prepared for the xture to light
and move suddenly when connected to power.
• The device should be positioned so that prolonged staring into the luminaire at a
distance closer than 5.151 m (16.90 ft) is not expected.
Disposal
• This product is supplied in compliance with European Directive 2012/19/EU – Waste
Electrical and Electronic Equipment
• (WEEE). To preserve the environment please dispose/ recycle this product at the end
of its life according to the local regulation.
The product contains a lithium ion battery
• Don't throw the unit into the garbage at the end of its lifetime.
• Make sure to dispose according to your local ordinances and/or regulations, to avoid
polluting the environment!
• The packaging is recyclable and can be disposed.
The products to which this manual refers comply with:
• 2014/35/EU - Safety of electrical equipment supplied at low voltage (LVD);
• 2014/30/EU - Electromagnetic Compatibility (EMC);
• 2011/65/EU - Restriction of the use of certain hazardous substances (RoHS);
• 2014/53/EU - Radio Equipment Directive (RED).
Minimun
distance
Risk
Group 2
Risk
Group 1
0.2 m
0.7 ft
5.151 m
16.90 ft

PROLIGHTS - Astra Beam260IP 05
1 - PACKAGING
PACKAGE CONTENT
• 1x ASTRABEAM260IP;
• 1x 1,5 meters power cable (SCHUKO plug - SEETRONIC IP65 power connector);
• 2x OSIP;
• 1x Antenna;
• User Manual.
OPTIONAL ACCESSORIES
• WSBBR512G6: blackBox R-512 G6 receiver 512Ch, 2.45GHz,DMX&RDM,Bluetooth,G3,G4,G4S,G5,CRMX;
• WSBBR512G5: blackBox R-512 G5 receiver 512Ch, 2.45GHz & 5.8GHz, DMX/RDM optional;
• WSBBF1G6: blackBox F-1 G6 transrec, 512ch, 2.45GHz, DMX&RDM,Bluetooth,G3,G4,G4S, G5, CRMX;
• WSBBF1G5: blackBox F-1 G5 transmitter, 2,45GHz & 5.2/5,8 GHz, DMX/RDM, 512Ch;
• INF53415L03: dmx cable HC5340. SETMC5MXXB XLR 5p->SETMC5FXXB XLR (f) 5p L.3m;
• 938225L03: 3x2.5mm TH07 Cable, 16A SETSAC3MX, 16A SETSAC3FX, L. 3m;
• 9313FXWL03: ass. 3x2.5mm TH07 cable, 16A 3p 230V CEE plug, SETSAC3FX socket, L.3 m;
• 9333FXWL03: ass. 3x2.5mm TH07 cable, SHUKO plug, SETSAC3FX socket, L.3m;
• RSR1235A/B: steel security cable for hanging bodies, inox steel shackle, L=120 cm, silver/black;
• C6002: Slim aluminium clamp, 200 kg loading, 48-51 mm tubes, M10 bolt;
• FCLASTRAB260IP: ight case for 2 pcs of ASTRABEAM260IP;
• OSIP: IP65 quick-lock omega bracket compatible with IP65 moving heads;
• IPTESTBOX: portable vacuum and pressure tester for ProLights IP xtures;
• UPBOX2: Firmware uploader kit, USB IN, 3-pin XLR DMX OUT.
2 - TECHNICAL DRAWING
385 mm
[15.2 in]
603 mm
[23.8 in]
292 mm
[11.5 in]
373 mm
[14.7 in]
538 mm
[21.2 in]
Fig. 01Weight: 28.6 kg - 63.05 lbs

PROLIGHTS - Astra Beam260IP06
3 - PAN AND TILT LOCK
PAN Mechanism lock and release
90°
90°
90°
90°
TILT Mechanism lock and release
45°
45°
45°
45°
45°
45°
Fig. 02

PROLIGHTS - Astra Beam260IP 07
Fig. 03
4 - INSTALLATION
MOUNTING
Check that the supporting structure can safely bear the weight of all installed xtures, clamps, cables,
auxiliary equipment, etc. and complies with locally applicable regulations.
When suspending the xture above ground level, secure it against failure of primary attachments by
attaching a safety wire that is approved as a safety attachment for the weight of the xture to an anchor
point on the product main frame.
Do not use removable parts or weak anchors for secondary attachment.
Warning! When clamping the xture to a truss or other structure at any angle, use clamps of half-cou-
pler type. Do not use any type of clamp that does not completely encircle the structure when fastened.
108 mm
4.2 in
108 mm
4.2 in
C6002
clamp RSR Steel security cable
OSIP

PROLIGHTS - Astra Beam260IP08
6 - START UP
CONNECT AND DISCONNECT POWER FROM THE PRODUCT
To apply and disconnect power to the product:
• Check that the product is installed and secured as indicated in the Safety Informations, and that
personal safety will not be put at risk when the xture lights up.
• Connect the power connector into the Mains input socket (100-240 VAC-50/60 Hz).
• The product is then ready for its operations and can be controlled through the available input sig-
nals on board.
• To disconnect power from the product, disconnect the Mains from the socket.
5 - CONNECTION TO THE MAINS SUPPLY
WARNING: For protection from electric shock, the xture must be earthed!
The product is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz
AC power source from 100-240 Volts.
If you need to install a power plug on the power cable to allow connection to power outlets, install a
grounding-type (earthed) plug, following the plug manufacturer’s instructions. If you have any doubts
about proper installation, consult a qualied electrician.
The max power consumption is 345W.
Core (EU) Core (US) Connection Plug terminal marking
Brown Black Live L
Blue White Neutral N
Yellow+green Green Earth
Inhaltsverzeichnis
Andere ProLights Außenleuchte Handbücher
Beliebte Außenleuchte Handbücher anderer Marken

LIGMAN
LIGMAN BAMBOO 3 Bedienungsanleitung

Maretti
Maretti TUBE CUBE WALL 14.4998.04 Bedienungsanleitung

Maxim Lighting
Maxim Lighting Carriage House VX 40428WGOB Bedienungsanleitung

urban ambiance
urban ambiance UQL1273 Bedienungsanleitung

TotalPond
TotalPond 52238 Bedienungsanleitung

Donner & Blitzen
Donner & Blitzen 0-02661479-2 Bedienungsanleitung