R44-1541 1
RS-232 INTERFACE PROGRAMMING
For your convenience, this guide provides minimal configuration and option
settings for your scanner's RS-232 interface. For more detailed programming
information and features, reference the SP400 Programming Guide (R44-1020) or the
QuickScan 6000/6000 Plus Programming Guide (R44-1540), available from your dealer.
THE QUICKSCAN 6000/6000 PLUS INTERFACE (I/F) CABLE
To disconnect the I/F cable at the scanner, insert a bent paper clip or 0.050" hex
driver into the opening marked CABLE RELEASE as shown in Figure 1, and push
inward. Once the connector latch is released, continue to hold the latch in while
carefully pulling the cable free.
Connect the QuickScan 6000/6000 Plus scanner to your system using ONLY the
proper PSC approved QuickScan 6000/6000 Plus I/F cable.
WARNING
Connection using an unapproved cable can result in
damage to the scanner. QuickScan 6000/6000 Plus
cablescanbeidentifiedbyacableI.D.codeprintedon
a white label, approximately 1” in length, attached to
them.
Interface
Connector
Overmolding
Latch
Approved
QS6000 Cable
DO NOT use
unapproved
cables without
the overmolding
Paper Clip
Cable Release
Figure 1. Disconnecting/Connecting the QuickScan 6000/6000 Plus I/F Cable
NOTE
QuickScan6000PlusI/F cablesofferanenhanced
capability that will automatically select the host-
specific interface type when the cable is attached.
For example, a scanner attached using an RS-232
cable will automatically communicate via RS-232;
when attached using a Keyboard Wedge cable, it
will automatically communicate with a Keyboard
Wedge system.