RESET:
Settings Re-set : Pressing and holding the RESET BUTTON on the remote control
or using the manual buttons to complete a RESET will restore the factory
settings to the illuminator. Note : It will not remove a PIN if one is present.
Full Re-set : Re-cycling the power whilst pressing both manual buttons will
restore factory settings and remove a PIN if one is present.
Both indicator LEDs flash amber for both above re-sets when complete.
VARIO2 Extreme Quick Troubleshoot:
Ensure all tests are undertaken by a qualified, trained engineer. Ensure safe
working practices are followed at all times.
•Check polarity of illuminator connection red=+ve, black=-ve
•Ensure power is 24VAC or DC
•Ensure telemetry wires are shorted out or valid telemetry input (zero volt or
5V Max Digital Signal) is applied and correctly wired
•Check photocell is working. Cover photocell fully, light should turn on if valid
telemetry input. It is sometimes difficult to see Infra-Red illuminators working in high
brightness conditions.
•Ensure power supply is suitably rated to product - check page 1 for
specifications
•If longer cables used, ensure sufficient voltage is provided to allow for drops
across the cable
For in-depth Troubleshoot, see Full Instructions, or contact Raytec.