Saab TankRadar PRO Bedienungsanleitung

User´s Guide

i
Edition 2. Ref. No: 306010E
Saab TankRadar®Pro
User´s Guide
Second edition
Copyright © September 1998
Saab Marine Electronics AB

Saab TankRadar®Pro
ii
Edition 3. Ref. No: 306010E
Copyright © March 1999
Saab Marine Electronics AB
The contents, descriptions and specifications within this manual is subject to
change without notice. Saab Marine Electronics AB accepts no responsibility
for any errors that may appear in this manual.
Trademarks
HART is a registered trademark of HART Communication Foundation
Modbus is a registered trademark of Modicon.
Pentium is a registered trademark of Intel Corporation.
Windows95 and Windows NT are trademarks of Microsoft Corporation.
Spare Parts
Any substitution of non-recognized spare parts may jeopardize safety. Repair,
e.g. substitution of components etc, may also jeopardize safety and is under no
circumstances allowed.
SaabTank Control will not take any responsibility for faults, accidents, etc
caused by non-recognized spare parts or any repair which is not made by Saab
Tank Control.
Specific FCC Requirements (USA only)
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1)This device may not cause harmful interfer-
ence, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
SaabTankRadar Pro generates and uses radio frequency energy. If it is not
installed and used properly, that is, in strict accordance with the
manufacturer´s instructions, it may violate FCC regulations on radio frequency
emission.
SaabTankRadar Pro has been Part 15 certified under test conditions which
assume a closed metallic tank.
Installation on non-metallic tanks, tanks with open manholes, external-float-
ing-roof tanks without stillpipes etc. are not covered by this certificate, and
require a Part 90 site-license. If you have an installation like this, contact your
SaabTank Control representative for help with the necessary license applica-
tion.

Saab TankRadar®Pro
iii
Edition 2. Ref. No: 306010E
Contents
About this manual........................................................ vii
1 Introduction............................................................ 1-1
The TankRadar Pro System .......................................................... 1-1
Measurement Principle.................................................................. 1-3
2 Mechanical Installation ......................................... 2-1
Socket Requirements .................................................................... 2-1
Free Space Requirements............................................................. 2-2
Dimensions..................................................................................... 2-3
Tools................................................................................................ 2-3
Mounting the Rod Antenna ........................................................... 2-4
Tank flange diameter = 50 mm (2”) .............................................. 2-4
Tank flange diameter = 65 mm (3”) .............................................. 2-5
Mounting the Cone Antenna - PTFE sealing ............................... 2-6
Mounting the Cone Antenna - Quartz Sealing ............................ 2-8
Mounting the Cone Antenna - Process Seal ............................. 2-10
Preparations ............................................................................... 2-10
Torque ........................................................................................ 2-13
Mounting the Parabolic Antenna................................................ 2-14
3 Electrical Installation ............................................ 3-1
Identication of Installed Options.................................................. 3-1
Junction Box .................................................................................. 3-2
External Connections.................................................................... 3-3
Non-Intrinsically SafeJunction Box -EEx e ................................... 3-3
Intrinsically Safe Junction Box - EEx i .......................................... 3-4
Alternative Non-intrinsically Safe Junction Box ............................ 3-5

Saab TankRadar®Pro
iv
Edition 2. Ref. No: 306010E
Connecting to a TRL2 Bus Interface............................................ 3-6
Connecting HART devices............................................................ 3-7
Active output (internal loop supply) .............................................. 3-7
Passive output (external loop supply)........................................... 3-7
Intrinsically safe conditions........................................................... 3-8
Non-Intrinsically safe conditions................................................... 3-8
Connecting the Display Panel ...................................................... 3-9
Cables ........................................................................................... 3-10
Safety ............................................................................................ 3-10
Power Supply ............................................................................... 3-10
Grounding .................................................................................... 3-10
CENELEC .................................................................................. 3-10
FM .............................................................................................. 3-10
System Overview ......................................................................... 3-11
Display Panel ..............................................................................3-11
Analog Outputs............................................................................3-11
Digital Communication.................................................................3-11
Power Supply ..............................................................................3-11
Internal Connections ................................................................... 3-12
Power Supply ............................................................................. 3-12
Display Panel ............................................................................. 3-12
Primary Output ........................................................................... 3-13
Secondary Output ...................................................................... 3-14
4 Pro Setup Software ............................................... 4-1
System Requirements ................................................................... 4-2
Installing the Pro setup software ................................................. 4-2
Starting the Pro Setup Program ................................................... 4-5
Setting a Password........................................................................ 4-6
Logging on to a password protected system. ............................ 4-7

Saab TankRadar®Pro
v
Edition 2. Ref. No: 306010E
Setting measurement units........................................................... 4-7
Installing a Pro Transmitter .......................................................... 4-8
Setting a general amplitude threshold........................................ 4-26
Creating a customized noise threshold table.............................. 4-26
Registration of False Echoes ..................................................... 4-29
Viewing Level Data ...................................................................... 4-33
Service .......................................................................................... 4-34
5 Using the Pro Display Panel................................. 5-1
Operation........................................................................................ 5-1
Entering a Password .................................................................... 5-2
Adjusting the LCD contrast........................................................... 5-2
Softkeys........................................................................................ 5-3
Presentation of measured data .................................................... 5-4
Selecting between different alternatives....................................... 5-5
Entering numerical values ............................................................ 5-6
Viewing Level Data ........................................................................ 5-7
The View Menu ............................................................................ 5-7
Installing a Pro Transmitter .......................................................... 5-9
Display Panel Setup ................................................................... 5-10
To change language ................................................................... 5-10
Guided Setup ..............................................................................5-11
Advanced Setup ......................................................................... 5-14
Service .......................................................................................... 5-25
6 Tank Distances ...................................................... 6-1
Definitions ...................................................................................... 6-1
Examples ........................................................................................ 6-3
7 Technical Information ........................................... 7-1
Technical Data................................................................................ 7-1

Saab TankRadar®Pro
vi
Edition 2. Ref. No: 306010E
Display Panel.................................................................................. 7-3
Analog Outputs.............................................................................. 7-3
8 Troubleshooting .................................................... 8-1
Display Panel Error Messages...................................................... 8-2
User Input Errors.......................................................................... 8-2
Internal Software Errors ............................................................... 8-2

Saab TankRadar®Pro
vii
Edition 2. Ref. No: 306010E
About this manual
This User´s Guide provides information about mechanical and
electrical installation of a SaabTankRadar Pro gauge. It also
describes how to start up and configure the gauge.
The main purpose of the book is to act as guide to installing and
operating a TankRadar Pro gauge. It is not intended to cover
service tasks such as changing circuit boards or internal software.
Chapter 1 reviews some basic concepts of radar based level gaug-
ing.
Chapter 2 describes how to assemble a gauge and how to mount it
on the tank.
Chapter 3 describes the electrical installation.
Chapter 4 describes how to use the Pro Setup software.
Chapter 5 describes how to use the Display Panel.
Chapter 6 describes the definitions of tank distances to use when
configuring a Pro transmitter.
Chapter 7 provides some technical information about TankRadar
Pro.
Chapter 8 lists some typical problems that might occur and sugges-
tions on how to solve them.

Saab TankRadar®Pro
viii
Edition 2. Ref. No: 306010E

Saab TankRadar®Pro Introduction
1-1
Edition 2. Ref. No: 306010E
1 Introduction
SaabTankRadar Pro is a powerful radar level gauge suitable for non-contact
level measurements in process tanks, storage tanks and other types of tanks.
It is designed for easy installation and maintenance free operation.
The modular hardware and software design makes it possible to specify a
TankRadar Pro gauge that will meet your requirements now and in the
future.
The TankRadar Pro System
The TankRadar Pro gauge offers a high degree of flexibility. It can be used
as a stand-alone unit, or it can be connected to various control systems.
You can integrate TankRadar Pro in your own Local Area Network (LAN).
By using the SaabTRL/2 Bus interface you can easily connect Pro gauges
to a SaabTankRadar L/2 system.
A specially designed software package, Pro Setup, offers configuration and
service capabilities. It also includes functions for presentation of measure-
ment data.
TankRadar L/2
Data Acquisition Unit
Field Communication
Unit
RTG 40
RTG 2930
Field Bus
Modem
Andere Handbücher für TankRadar PRO
2
Inhaltsverzeichnis
Andere Saab Messgerät Handbücher