8 ETHM-1 Plus SATEL
−JAVA application in the web browser,
−INTEGRA CONTROL / MOBILEKPD / MOBILEKPD-2 / MOBILEKPD-2 PRO in the mobile
device.
You can enter values from 1 to 65535. The value must be different from that entered for
the other ports. Default value: 7091.
WWW port – number of the TCP port used for communication with the web browser. You
can enter values from 1 do 65535 The value must be different from that entered for the
other ports. Default value: 80.
GUARDX/Java key [Key (others)] – a string of up to 12 alphanumeric characters (digits,
letters and special characters) used for data encryption during communication between the
control panel and:
−GUARDX program,
−JAVA application in the web browser,
−INTEGRA CONTROL / MOBILEKPD / MOBILEKPD-2 / MOBILEKPD-2 PRO in the mobile
device.
GUARDX server [GUARDX IP] – address of the computer running the GUARDX program. If
the computer is not used in the same local network, it must be a public address. You can
enter either the IP address or the domain name.
In the keypad, the function for programming address of the computer with GUARDX
program installed is available in the user menu, CHANGE OPTION submenu (available to
service and administrators).
PING test
PING test – if this option is enabled, the module can perform a communication test using the
ping command sent to the indicated network device. Parameters related to the
communication test should be programmed in the control panel:
LCD keypad: SERVICE MODE OPTIONS PING TEST,
DLOADX program: “Structure” window “Hardware” tab “Keypads” branch.
SATEL server
Connection via Satel server [SATEL server] – if this option is enabled, the control panel
connects to the SATEL server via the Ethernet module, while the SATEL server makes it
possible to establish communication with the control panel (Connection Establishing
Service). For communication vie the SATEL server, you do not need to additionally
configure the network device through which the module connects to the public network.
For establishing communication with the SATEL server, the DNS server must be used.
For communication via the SATEL server, the ports of 1024-65535 range are used as
outgoing ports. These ports must not be blocked.
Push notifications – if this option is enabled, the INTEGRA CONTROL application can
provide information about alarm system events by means of push notifications.
Integration
Integration [Integrate] – if this option is enabled, the module can be used for integration of
the alarm control panel with other systems.
Encrypted integration [Coded integr.] – if this option is enabled, communication with other
systems is encrypted. The integration encryption key should be programmed in the control
panel:
LCD keypad: SERVICE MODE OPTIONS INTEGRATE KEY,