Scantronic 9800+ Bedienungsanleitung

HARDWIRED CONTROL
PANEL
USER GUIDE
Scantronic
Leading the way in security
(16 ZONE)

9800+ (16 Zone) Hardwired Control Panel User Guide.
© Scantronic td. 1997
Every effort has been made to ensure that the
contents of this book are correct. However, neither the
authors nor Scantronic accept any liability for loss or
damage caused or alleged to be caused directly or
indirectly by this book. The contents of this book are
subject to change without notice.
Printed and published in the U.K.
Contents
1. Introduction 3
The 9800+ (16 zone) System ........ 3
The Keypad ................................... 3
About This Guide ...........................
2. Everyday Operation 6
How Do I Know if the System is
Working? .................................. 6
Setting the System ........................ 6
Timed Final Set .............................. 6
Exceeding the Exit Time ........... 7
Final Door Set ................................ 7
Exit Terminate Button Set ............... 7
Part Setting..................................... 8
Instant Set ................................ 8
Keys itch Setting ........................... 8
If the System Will Not Set .............. 8
Unsetting the System .................... 9
Unsetting From a Keys itch .......... 9
Unsetting From the Keypad ........... 9
If You Exceed the Entry Time ... 9
3. After an Alarm 10
Fire Alarm .................................... 10
Disarming the System ................. 10
Resetting the System .................. 10
Customer Reset ............................11
Remote Reset ...............................11
4. Special unctions 12
Introduction.................................. 12
Omitting Zones ............................ 12
Omitting 24 Hour Zones ............... 13
Setting the Time and Date ........... 13
Access Codes ............................. 14
Duress Code ................................ 14
Changing Access Codes .............. 14
Using the Log .............................. 1
Table 1. Log Event Codes ............ 15
Table 1 (Cont'd) . Log Event Codes
16
Turning the Chime On/Off............ 16
Testing the System ...................... 16
Bell Test ........................................ 16
Walk Test ...................................... 17
5. System aults 18

496247 Issue 4 3
1. Introduction
The 9800+ (16 zone) System
The 9800+ (16 zone) system comprises a control unit, one or more keypads,
and various detectors.
The control unit is a steel box that houses the main controller, power supply,
stand-by battery, and any remote communicator. The control unit is normally
fitted out of sight in a safe place (for example under the stairs).
The detectors are installed at various places, or zones, around the premises.
If something triggers a detector then it signals back to the control unit. How
the control unit reacts depends on whether the system is set or unset.
When set the system raises an alarm whenever a detector is triggered. The
alarm might be a bell or strobe on the outside of your premises, or it might be
a silent signal over the telephone line to a central monitoring station. When
unset the system does not raise an alarm if a detector is triggered.
The system provides three different setting Levels, labelled A, B, and C.
Level A sets the whole system, protecting all of the premises covered by the
alarm system. Levels B and C set part of the system, protecting part of the
premises while the rest is in use. The system raises an alarm when a detec-
tor belonging to a set Level is triggered. The Installer programs the Levels
during installation. Ask your Installer to tell you which zone is allocated to
each Level.
Your premises may be fitted with 24 hour zones and panic alarm zones. If
these zones are triggered the system will raise an alarm whether or not any
Level is set.
The Keypad
From the keypad you can set and unset the system, read the event log, and
make minor changes to the way the system operates.
You must enter an access code before the system will accept commands
from the keypad. The system can store up to 8 different access codes,
providing secure access for 8 users.
Figure 1 below shows the keypad in detail.

4 496247 Issue 4
Figure 1. 9800+ Keypad
The keypad has the following displays and controls:
A, B, C LEDs These LEDs (Light Emitting Diodes) glow to show
which Level is set. The LEDs are dark when the
Levels are unset. Note that the installer can pro-
gram the system to hide the display.
Day LED The Day LED glows when the system is unset. The
LED goes dark when the system is set. Note that
the installer can program the system to hide the
display.
Fault LED The Fault LED glows when the system is in alarm,
if the system has detected a fault on the telephone
line, or if the internal battery has failed.
Service LED The Service LED glows when the panel needs an
engineer to reset it, or the system has detected an
internal problem. Call your alarm installer.
Power LED The Power LED glows when the system is using
mains power. If the Power LED flashes slowly then
the mains power has been disconnected and the
system is running off the stand-by battery.
LED Display The system displays information and instructions
through the two character LED display.
1. Introduction
2 digit Light Emitting
Diode (LED) Display
Optional programmable
panic alarm keys. Press
keys 1 and 3 together
Omit and Clear keys
Le els LEDs (Set or
Unset)
Le el setting keys
Power

496247 Issue 4 5
Level Setting Keys Use these keys to set individual Levels. A sets the
whole system. B and C set part of the system. (D is
not active.) Note that you will have to use your
access code first.
Panic Alarm Keys Press keys 1 and 3 together to raise a personal
attack alarm. (Check with your Installer that your
system is programmed with this function.)
3 (Clock) Press 3 to change the time and date stored in the
system.*
4 (Code) Press 4 to change access codes.*
(Log) Press to read a record of events that have
occurred on your system.*
7 (Chime) Press 7 to switch the Chime function on or off.*
8 (Bell test) Press 8 to start a bell test.*
9 (Walk test) Press 9 to start a walk test.*
X (Omit) The X key (Omit on 9800 keypads) lets you omit
(bypass) zones when setting the system. Note that
the Installer must program individual zones so that
the system will allow you to bypass them.
y (Clear) The y key (Clear on 9800 keypads) tells the
system that you have finished entering an access
code (or other command).
* (see "4. Special Functions")
About This Guide
The rest of this guide tells you how to use the system in more detail:
2. Everyday Operation Describes how to set and unset the system.
3. After an Alarm Tells you how to switch off the sounders after an
alarm, how to see what caused the alarm, and how
to reset the system so that it can be used again.
4. Special Functions Tells you how to use the more advanced features
of the system.
. System Faults Tells you what to do if the alarm system reports a
fault.
1. Introduction

6 496247 Issue 4
2. Everyday Operation
There are several different ways of setting the system. For all methods (except
using a Keyswitch) you must enter your access code at the keypad. The
Keyswitch method uses a key in a special switch fitted to your premises.
"Setting the System" below describes each method. Ask your Installer to
provide the method that suits your site best.
During installation the Installer programs the system to create an exit route
for your premises. When setting the system you must follow this route to
leave the premises. Similarly you must follow a specified entry route when
going into the premises in order to unset the system. If you stray from these
routes you may cause a false alarm.
How o I Know if the System is Working?
The Power LED always glows when the mains power is present. If the Power
LED flashes slowly then mains power is off, and the system is working from
its internal battery. If the Power LED is dark then the system is dead.
When the system is set, a Level LED glows to show which Level key was
used. When the system is unset, the Day LED glows. However, the Installer
can program the system to hide these displays. Ask your installer how the
system is set up.
If you wish to test the system and its detectors, see "4. Special Functions -
Testing the System".
Setting the System
Timed Final Set
With Timed Final Set the system sets after a programmed exit time has
expired. Ask your Installer to make sure the exit time is long enough for you
to leave the premises and close the final door.
1. Close all doors and windows.
2. Key in your access code at the keypad.
3. Press the appropriate Level key.
The exit time starts when you press the Level key. During the exit time
the Level LED flashes and the keypads give a continuous exit tone to
warn you that the timer is running.
If you hear an interrupted tone from the keypads or internal sounder
then one of the detectors is operating. The keypad shows the zone
number of the detector. Make sure that all doors and windows are
closed.

496247 Issue 4 7
4. Leave via the designated exit route. Close the final door.
At the end of the exit time the system sets, and stops the exit tone. The
Level LED glows steadily to show which Level is set.
Note: If you change your mind about setting the system either press y (Clear) within
five seconds of entering your code, or key in your access code again if you
miss the first five seconds.
Exceeding the Exit Time
If you do not close the final door before the end of the exit time then the
system gives an alarm and does not set. You can cancel this false alarm by
entering your access code at the keypad immediately.
When you have cancelled the alarm you will have to reset the system and
restart the setting procedure.
Final oor Set
With Final Door setting the system sets when you close the last door. There
is no fixed exit time.
1. Close all doors and windows.
2. Key in your access code at the keypad.
3. Press the appropriate Level key.
The keypad starts the continuous exit tone and the Level LED flashes.
4. Leave via the designated exit route and close the final door.
Exit Terminate Button Set
In Exit Terminate Button setting the system completes setting after you press
a button mounted outside the premises by the final door.
1. Close all doors and windows.
2. Key in your access code at the keypad.
3. Press the appropriate Level key.
The keypad starts the continuous exit tone and the Level LED flashes.
4. Leave via the designated exit route. Close the final door.
. Press the exit terminate button.
The exit tone stops and the system sets. The Level LED glows steadily.
Note: The Installer may have programmed your system to set after a fixed time even
if you do not press the exit terminate button. This is to make sure your
premises are protected even if you forget to press the exit terminate button.
sk your Installer how your system is set up.
2. Everyday Operation

8 496247 Issue 4
Part Setting
The Installer may have programmed your system so that you can protect part
of the premises while the rest is in use. Level keys B and C can give two part
set areas, ask your installer which areas each key covers.
1. Close doors and windows in the protected area.
2. Key in your access code at the keypad.
3. Press the Level key B or C as necessary.
The keypad starts the continuous exit tone and the Level LED flashes
(see "Instant Set" below).
4. Leave via the designated exit route and if necessary close the final door.
The exit tone stops and the system sets. The Level LED glows steadily
to show which Level is set.
Note: Some Levels on your system may be programmed for Silent Set. When
setting these Levels the system does not give any tones from the keypads or
internal sounder.
Instant Set
The area protected by a part set system may not need an exit route or final
exit door. For these areas the Installer may program the Level key protecting
the area as Instant Set. With Instant Set the system sets as soon as you
press the Level key. Note that Instant set is only available on level keys B
and C.
Keyswitch Setting
1. Close all doors and windows. The Ready lamp on the keyswitch should
be glowing to indicate that all the detectors are closed. (Some types of
keyswitch do not have lamps.)
2. Turn the keyswitch to "Set".
3. Leave the premises and close the final door.
The system sets.
If the System Will Not Set
If you try to set the system while a detector in the protected area is reporting
an open door or window then the keypad will give an interrupted tone and the
display will show the zone number of the detector.
1. Enter your access code at the keypad.
The interrupted tone stops and the Day LED glows.
2. Go to the zone shown on the display and find out what is triggering the
detector. If possible remedy the fault.
2. Everyday Operation

496247 Issue 4 9
3. Return to the keypad and set the system again.
If no other detectors are active the system sets.
4. Repeat steps 1 to 3 if the display shows other zones.
. If you still cannot set the system then call the engineer.
Unsetting the System
Unsetting From a Keyswitch
Turn the keyswitch to OFF. The system unsets immediately.
Unsetting From the Keypad
The system has a programmed entry time. Ask your Installer to make sure
the entry time is long enough for you to enter by the designated entry route,
get to the keypad and unset the system.
The entry time starts when you open the designated entry door. During the
entry time the keypads give a "galloping" entry tone to warn you that the
timer is running.
1. Enter through the designated entry door and go to the keypad.
As you enter the premises the system starts the entry timer and the
keypad gives the entry tone.
2. Key in your access code at the keypad.
The entry tone stops. The system is now unset.
WARNING: If you enter your premises and an internal alarm
starts then there may be an intruder.
If You Exceed the Entry Time
If you regularly have problems exceeding the entry time, ask your installer
about "Dual Ply Entry" and "Alarm Abort".
If the system is programmed for Dual Ply Entry, then the control unit adds a
30 second grace period to the end of the Entry Time. During that grace
period the keypads give a high pitched continuous tone to warn you that the
Entry Time has run out.
When programmed for Alarm Abort the system gives you 90 seconds after
the end of the Entry Time to cancel any alarm caused by exceeding the Entry
Time or leaving the entry route. If you exceed the 90 second Alarm Abort
time then the panel gives a full alarm, and you may have to call an engineer
to reset your system.
2. Everyday Operation

10 496247 Issue 4
3. After an Alarm
3. After an Alarm
When your system raises an alarm you must disarm it in order to switch off
the sounders and strobes. The system keeps a record of which zone(s)
triggered the alarms, and shows the zone number(s) on the keypad display.
Once you have disarmed the system, the system must be reset before you
can start using it again.
Fire Alarm
The system gives a fire alarm by sounding a warbling tone from the keypads
and alarm sounder. The display shows the letters "Fr".
1. Evacuate the premises and call the Fire Brigade. Do not attempt to
unset the alarm.
2. When the premises are safe, follow the instructions below.
isarming the System
1. Go to the keypad via the entry route.
2. Key-in your access code.
The sounders go quiet, the Day and Fault LEDs glow, and the display
shows the letter "c" with the zone number of the first detector to be
triggered. You may also see the Service LED glowing.
3. Establish the cause of the alarm.
4. Carry on to reset the system.
Resetting the System
There are three different methods for resetting. You can tell which method
your system uses by looking at the Service LED after an alarm.
If the Service LED is dark then the system uses Customer Reset.
You can reset the system yourself from the keypad.
If the Service LED glows after an alarm then your system uses
Engineer Reset. Call your alarm company and ask for an engineer
to visit the premises to reset the system.
If the Service LED glows after an alarm and your system is con-
nected to a central monitoring station then your system may use
Remote Reset. Your alarm company will give you instructions over
the phone and a special code so that you can reset the system
from the keypad.
Andere Handbücher für 9800+
1
Inhaltsverzeichnis
Andere Scantronic Bedienfeld Handbücher

Scantronic
Scantronic 9100 Betriebsanleitung

Scantronic
Scantronic 808 Bedienungsanleitung

Scantronic
Scantronic 9448+ Installationsanleitung

Scantronic
Scantronic 9448+ Bedienungsanleitung

Scantronic
Scantronic 9448+ Bedienungsanleitung

Scantronic
Scantronic 601 Installationsanleitung

Scantronic
Scantronic 8136 Bedienungsanleitung

Scantronic
Scantronic 9448+ Bedienungsanleitung

Scantronic
Scantronic 9800+ Bedienungsanleitung

Scantronic
Scantronic 9449 Bedienungsanleitung