SELTEX V350 Bedienungsanleitung

SWING GATE OPENER
≦150kg
≦1.75m
≦150kg
≦1.75m
USER MANUAL
V350

03
03
03
04
04~07
08
09
10
11
12
13
14
15
16
16
17
17
17
17
17
18
19
20
..........................
......................................
.................................
.......................................
..........................................................
.....................................................
..............................................
.....................................................
...........................................
...........................................................
..................................................
.......................................................
.....................................
...............................
.............................................
...............................................
..........................................
.................
............................................
..............................................................
............................
.............................................
................
Important Safety Advice
Content of the Kit
Connection Diagram
Installation Guide
Actuator
Control box
AC cable wiring
Transformer
Connection PCBA
Actuator
Warning light
Photocells
Function of photocells
Opening/Closing learning
Remote learning
Remote control
Auto close function
Manual gates control on the PCBA
Clear RF memory
Reset
Setting of the Dip Switches
Specifications
Declaration of CE Conformity
2
Content

Content of the Kit
Important Safety Advice
1. Knowledge of relevant electro-technical regulations is required.
2. Training in use and maintenance of safety equipments is necessary.
3. Professional assistance is required when some mechanism adjustment is needed.
4. Always lay mains and control cables separately.
5. Test every equipment before initial operation.
6. Make familiar with the use of the system before initial operation.
3
Remote control Warning light Baery wire
x2
Control box Wire conduit
(PG11)
Connection Diagram
x2
Gate side brackets
Pillar side brackets
x2
x2
x2
Fixing bolts
Snap pins
Actuator
x2
Warning light
Control box
Photocells Photocells
Actuator Actuator

4
The maximum opening angle depends on the distance (D) between the gate hinge to the edge of the
pillar. The table below gives the opening angle according to (D)
Pillar
B
1
2
3
4
5
D
Actuator:
Installation Guide
Distance D (mm)
0 < D < 170
0 < D < 110
Angle (º)
90
100
0 < D < 60
D < 20
110
120
Distance D
(mm)
170
160
150
140
130
120
110
100
90
80
Angle max.
(º)
90
100
95
70
60
50
40
30
20
10
0
Distance B
(mm)
110
115
120
135
130
145
140
135
150
100
145
155
150
160
150
160
150
150
105
110
115
120
5
5
5
5
5
5
5
5
5
5
4 or 5
5
4
4 or 5
4
4
4
4
The bracket holes
(Gate side bracket)
INCORRECT
Pillar
hinge pin
> 170mm
CORRECT
Pillar
hinge pin
= 170mm
100mm
IMPORTANT:
If the hinge of your gate is more than 170mm from the edge of the pillar, it is necessary to adapt the
pillar to ensure the hinge is less than 170mm from the edge of the pillar, to reach a 90º opening.
Angle
Pillar
D

5
Pillar side:
Find the desired value B, according to the value D, as described in the previous table explaining the
opening angle. Make sure the pillar side bracket is placed horizontally, with the use of a spirit level, before
you drill the holes for the bracket.
Mark a line on the lower frame of your gate, as shown below, and allow a 16mm vertical distance as it’s
the height difference between the lowest part of the pillar side bracket, and the tallest part of the gate
side bracket, as shown below.
16mm
B
16mm
Use a spirit level to be sure
that the mounting bracket
can be placed horizontally.

6
1
2
3
4
5
Gate side:
Fasten the wing nut in this direction.
Make sure the gate side bracket is placed horizontally, with the use of a spirit level, before you drill the
holes for the bracket.
16mm
Use a spirit level to be sure that
the mounting bracket can be
placed horizontally.
Put the fixing bolt downwards through the hole of the actuator, and the hole of the pillar side bracket.
And use the snap pin to keep them in place.

7
bottom view
5mm
Normally the nut is at a distance of 5mm from the fully close position. You can drive the nut to this position,
in case the nut is not at the proper position.
- Move the nut with a battery. The below diagrams indicate which direction the nut moves when the motor
wires are connected directly to a 12VDC battery.
Black
Red
Red
Black

Control box:
2. Unfasten the two screws and remove the
cover.
3. Fix the control box on the wall.
※ M8 screws are suggested (not provided).
AC12V
Auto ClearRF2
J1
O / C
LED1
BAT
- +
1 2 3 4 5 6
ON
Lamp
RF1
DIP
LED O/C1 O/C2 GND ANT
-
M2
+
-
M1
+ -
Warm
+
+12VCOM
GND NC
Min. 60cm
AC12V
Auto ClearRF2
J1
O / C
LED1
BAT
- +
1 2 3 4 5 6
ON
Lamp
RF1
DIP
LED O/C1 O/C2 GND ANT
-
M2
+
-
M1
+ -
Warm
+
+12VCOM
GND NC
1. Use a screw driver to unfasten the screws
of the cover and open the control box.
8

2. AC cable goes at the left side of the control box through the wire conduit.
AC12V
Auto ClearRF2
J1
O / C
LED1
BAT
- +
1 2 3 4 5 6
ON
Lamp
RF1
DIP
LED O/C1 O/C2 GND ANT
-
M2
+
-
M1
+ -
Warm
+
+12V COM
GND NC
Connect the AC cable as shown below.
1. Mount the wire conduit at the left side of the control box.
AC12V
Auto ClearRF2
J1
O / C
LED1
BAT
- +
1 2 3 4 5 6
ON
Lamp
RF1
DIP
LED O/C1 O/C2 GND ANT
-
M2
+
-
M1
+ -
Warm
+
+12V COM
GND NC
AC cable wiring:
AC12V
Auto ClearRF2
BAT
- +
1 2 3 4 5 6
ON
RF1
DIP
3. Connect the AC plug to the power and check th if the LED on the board is ON.
9
AC12V
Auto ClearRF2
J1
O / C
LED1
BAT
- +
1 2 3 4 5 6
ON
Lamp
RF1
DIP
LED O/C1 O/C2 GND ANT
-
M2
+
-
M1
+ -
Warm
+
+12V COM
GND NC
AC12V
Auto ClearRF2
J1
O / C
LED
BAT
- +
1 2 3 4 5 6
ON
Lamp
RF1
DIP
LED O/C1 O/C2 GND ANT
-
M2
+
-M1+ -
Warm
+
+12V COM
GND NC
*If the LED is ON, remove the AC plug, and put back the cover of the transformer.

10
Use a screw driver to fasten the 4 screws of the control box.
Transformer:
AC12V
Auto ClearRF2
J1
O / C
LED1
BAT
- +
1 2 3 4 5 6
ON
Lamp
RF1
DIP
LED O/C1 O/C2 GND ANT
-
M2
+
-
M1
+ -
Warm
+
+12V COM
GND NC
Put back the cover.
Use a screw driver to fasten
the 2 screws of the cover.
AC12V
Auto ClearRF2
J1
O / C
LED1
BAT
- +
1 2 3 4 5 6
ON
Lamp
RF1
DIP
LED O/C1 O/C2 GND ANT
-
M2
+
-
M1
+ -
Warm
+
+12V COM
GND NC
Dieses Handbuch passt für folgende Modelle
1