Sencore VB440 Bedienungsanleitung

VB440 SDI over IP Analyzer
User’s Manual
Applies to software release v6.0
April 2021

VB440 SDI over IP Analyzer User’s Manual
Revision 87ab646 (2021-04-28)
Copyright
© 2021 Sencore, Inc. All rights reserved.
3200 Sencore Drive, Sioux Falls, SD USA
www.sencore.com
This publication contains confidential, proprietary, and trade secret information. No part of this document
may be copied, photocopied, reproduced, translated, or reduced to any machine-readable or electronic
format without prior written permission from Sencore. Information in this document is subject to change
without notice and Sencore Inc. assumes no responsibility or liability for any errors or inaccuracies.
Sencore, Sencore Inc, and the Sencore logo are trademarks or registered trademarks in the United
States and other countries. All other products or services mentioned in this document are identified by
the trademarks, service marks, or product names as designated by the companies who market those
products. Inquiries should be made directly to those companies. This document may also have links to
third-party web pages that are beyond the control of Sencore. The presence of such links does not imply
that Sencore endorses or recommends the content on those pages. Sencore acknowledges the use of
third-party open source software and licenses in some Sencore products. This freely available source
code can be obtained by contacting Sencore Inc.
About Sencore
Sencore is an engineering leader in the development of high-quality signal transmission solutions for the
broadcast, cable, satellite, IPTV, and telecommunications markets. The company’s world-class portfolio
includes video delivery products, system monitoring and analysis solutions, and test and measurement
equipment, all designed to support system interoperability and backed by best-in-class customer support.
Sencore products meet the rapidly changing needs of modern media by ensuring the efficient delivery
of high-quality video from the source to the home. More information about Sencore is available at the
company’s website, www.sencore.com.
This product can include software developed by the following people and organizations with the following
copyright notices:
• Curl. Copyright © Daniel Stenberg and many contributors. All rights reserved.
• Dropbear. Contains software copyright © 2008 Google Inc. All rights reserved.
• OpenSSL Project for use in the OpenSSL Toolkit. (http://www.openssl.org/).
Copyright © 1998-2017. The OpenSSL Project. All rights reserved.
All trademarks and registered trademarks mentioned herein are the property of their respective owners.

Contents
Contents 3
1 Introduction 4
1.1 About the VB440 SDI over IP Analyzer ....................... 4
1.2 How to Use This Manual ............................... 4
2 SAFETY 5
3 Installation and initial setup 6
3.1 Prerequisite ...................................... 6
3.2 Quick Installation Guide ............................... 6
3.3 Accessing the User Interface ............................ 7
3.4 Graphical User Interface ............................... 8
3.5 Configuring Ethernet settings ............................ 9
4 The VB440 Graphical User Interface 10
5 The VB440 expert user interface 47
5.0.1 Monitoring/configuration – Summary .................... 48
5.0.2 Multicasts — Streams ............................ 50
5.1 Data .......................................... 54
5.1.1 Data — Configuration ............................ 54
5.1.2 Data — OS Update ............................. 55
5.1.3 Data — Eii .................................. 56
A Appendix: PTP and BMCA 57
B Appendix: 2110 Timing model 60
VB440 SDI over IP Analyzer User’s Manual version 6.0 3

1 Introduction
1.1 About the VB440 SDI over IP Analyzer
The VB440 SDI over IP Analyzer performs monitoring and analytics in real-time for high bitrate
streams typically seen in studios. It supports RTP streams carrying SMPTE 2022-6 and 2110 streams,
optionally protected by SMPTE 2022-7.
The VB440 SDI over IP Analyzer enables operators to inspect the individual streams and to verify
that they are compliant.
The VB440 SDI over IP Analyzer comes with dual 100Gbps network ports, making it a future proof
solution. Each VB440 SDI over IP Analyzer runs an HTTP server with the client as a web browser,
so there is no need to install custom software on computers needing access to the measurement data.
1.2 How to Use This Manual
This User’s Manual is valid for software version 6.0 of the VB440 SDI over IP Analyzer.
Throughout this manual the term stream is often used rather than unicast or multicast. One stream
may consist of one or more services, and refers to one IP uni- or multicast.
Chapter 2
SAFETY
lists safety precautions, and this chapter should be read prior to equipment
installation.
Chapter 3
Installation and initial setup
explains how to install the equipment and also how to
perform the necessary initial configuration of the VB440 SDI over IP Analyzer management IP
address. A step-by-step quick installation guide is found in section 3.2.
Chapter 4
The VB440 Graphical User Interface
describes the graphical user interface (GUI) as
seen when pointing a web browser to the VB440 SDI over IP Analyzer’s IP address.
5.1.2
Data — OS Update
explains how to upgrade the software on the VB440 SDI over IP Analyzer.
Note that current version of the User’s Manual can be obtained from Sencore ProCare support by
emailing [email protected].
4VB440 SDI over IP Analyzer User’s Manual version 6.0

2 SAFETY
Read the installation instructions before connecting the chassis unit to the power source. Do
not install the chassis unit with power on.
The chassis or the portable unit is intended for installation in restricted access areas. A re-
stricted access area can be accessed only through the use of a special tool, lock and key, or
other means of security.
Blank face plates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis, they provide electromagnetic interference
shielding and they direct the flow of cooling air through the chassis. Do not operate the chassis
unit unless all modules, face plates, front covers and rear covers are in place.
Only trained and qualified personnel should be allowed to install, replace or service this equip-
ment.
This equipment must be installed and maintained by service personnel as defined by AS/NZS
3260. Incorrectly connecting this equipment to a general-purpose outlet could be hazardous.
If SFP modules are used ensure proper precautions are taken to protect eyes against harmful
infrared radiation. Do not look straight into the SFP module or fibers connected to the SFP
module. The SFP modules employed are certified in Laser Class 1.
Ultimate disposal of this product should be handled according to all national laws and regu-
lations.
To prevent the system from overheating, do not operate it in an area that exceeds the maxi-
mum ambient temperature of 45 degrees Celsius.
Do not work on the system or connect or disconnect cables during periods of lightning activity.
VB440 SDI over IP Analyzer User’s Manual version 6.0 5

3 Installation and initial setup
3.1 Prerequisite
To connect the appliance you need the following:
• Two power cables for the redundant PSU
• 1 or 2 RJ45 1 Gbps Ethernet ports for management
• QSFP28 connectors for the data ports, or a QSFP cage + supported SFP module
Supported QSFP28 protocols:
• 100GBASE-CR4
• 100GBASE-KR4
• 100GBASE-SR4
• 56GBASE-R4
• 50G Ethernet Consortium
• 40GBASE-CR4
• 40GBASE-SR4
• 40GBASEL-R4
• 40GBASE-ER4
• 25GBASE-CR/CR-S
• 25GBASE-SR
• 25GBASE-LR
• 25G Ethernet Consortium
• 10GBASE-SR
• 10GBASE-LR
• 10GBASE-ER
• 10GBASE-CX4
• SGMII
• 1000BASE-X
3.2 Quick Installation Guide
6VB440 SDI over IP Analyzer User’s Manual version 6.0

Connect one or both of the management cables. Please note that with the default configuration
MGMT 1 (Orange) is configured with a static IP, and MGMT 2 (Green) is configured using DHCP.
If you choose to use the static port, the pre-configured address will be 10.0.20.101/24.
The server also has an IPMI port that can be connected if wanted. It is configured to use DHCP and
the username
ADMIN
and the password is either written on a pull-out tab in front of the machine, or
on the IPMI-port inside the chassis. On older versions of the hardware, the password was
ADMIN
.
Insert the QSFPs into the Primary (Blue) and Secondary (Red) ports, choosing a supported QSFP-
type from the list above.
You can then connect the two power cables and power the server on.
3.3 Accessing the User Interface
Once the server has been connected to the network, you can use a browser to connect to the user
interface.
Please note that, for optimum results, Chrome is recommended to manage the VB440.
To connect to the VB440, you will either have to have mDNS and IPv6 working (typically only on
Mac OS) or know the IP. If you have connected to the static management port, the default address
should be 10.0.20.101. Your machine will have to be on the same network in order to reach it
through that address. If you have connected it to the DHCP management port, you will either have
to get the IP from your DHCP server, or from the printout in the console.
Depending on if the product is enabled and is properly licensed you either get the enable / license
UI or the main UI up.
VB440 SDI over IP Analyzer User’s Manual version 6.0 7

If you get a HTTPS certificate warning, just accept it.
If you get a login page as seen above, the product has not yet been activated. If you do not get a
login page, go straight to section 3.4
Log in using the username root and the password elvis.
On the
Software activation
screen, expand the IP-Probe menu and input both the software license,
and the software maintenance license, pressing
Add license
after each license. When all the licenses
have been accepted, press the
Activate
button. You can now access the regular probe UI by going
straight to the IP again.
To get back into the system admin dashboard, go to http://IP/admin/.
3.4 Graphical User Interface
The default GUI should look similar to the following picture. For more information, refer to
chapter 4.
8VB440 SDI over IP Analyzer User’s Manual version 6.0

3.5 Configuring Ethernet settings
The VB440 comes with built in support for editing the network interface settings. To access the
system admin interface, point your browser to http://IP/admin/ and log in using the default system
username root and the password elvis.
This is described in more detail in the System Administration part of the manual.
VB440 SDI over IP Analyzer User’s Manual version 6.0 9

Navigation Menu
The navigation menu is located in the top left corner and can be made visible or
hidden by clicking the navigation menu button. The navigation menu is marked
with three horizontal lines, and is accessible from any page.
The navigation menu consists of four different icons that will help you navigate to
the preferred view. The icon shaped like a tv screen leads to the Services View.
Next there is a signal symbol that takes you to the Flow View. The clock indicates
the Status View. Note that Status view also is the landing page when you first
open the probe in a browser. The last symbol illustrates a tool box which opens
the Expert view.
Status View
Displays a generalized overview of the probe, divided into four sections:
●Network Status
●PTP Clocks
●Video Engine Statistics
●Video Streaming Statistics
Note that the page uses responsive design. If the viewport is small, some of the sections
seen in the screenshots below will not be visible.
Network Status
4 The VB440 Graphical User Interface
10 VB440 SDI over IP Analyzer User’s Manual version 6.0
Inhaltsverzeichnis
Andere Sencore Messgerät Handbücher

Sencore
Sencore cm2125 Benutzerhandbuch

Sencore
Sencore SLM 1479 Bedienungsanleitung

Sencore
Sencore DigiPro DA795 Bedienungsanleitung

Sencore
Sencore SLM 1530 Bedienungsanleitung

Sencore
Sencore SP395 Bedienungsanleitung

Sencore
Sencore ReZolver LC103 Benutzerhandbuch

Sencore
Sencore VB330 Bedienungsanleitung

Sencore
Sencore VC93 Bedienungsanleitung

Sencore
Sencore ReZolver LC103 Benutzerhandbuch

Sencore
Sencore VB330 Bedienungsanleitung
























