Shuttle 2000-1 Bedienungsanleitung

Page 1
2000-1

Congratulations on the purchase of your new Shuttle 2000-1. Shuttle equipment has been trusted by
physical therapists and sports training facilities around the globe for almost half a century. It is our
mission to deliver the finest quality exercise devices with superior customer service. We welcome you
as a valued customer.
For your safety it is crucial that you read this manual thoroughly and understand the equipment before
use. If you have any questions about your Shuttle 2000-1 you can give us a call at +1 (800)-334-5633,
www.shuttlesystems.com (Monday-Friday, 8 am to 5 pm Pacific Time).
WELCOME TO THE FAM

IMPORTANT SAFETY INFORMATION …………………………….……………………………………..……. 1
PERSONAL SAFETY ……………………………..….….…………………………………………………..……. 1
SPECIFICATIONS ………………………………………………….…………………………………….…..…… 2
IDENTIFICATION OF THE MANUFACTURER ……………………………………………………..……….…. 3
ASSEMBLY OF THE 2000-1 ……………………………………………………………………….…..………… 4
- ATTACHING STAND-ENDS TO CONNECTOR BAR…………………………………..5
- ATTACHING THE RAILS AND CARRIAGE TO STAND-ENDS………….……………..6
- MOUNTING THE KICKPLATE STRUCTURE……………………………….…………….8
- ATTACHING THE KICKPLATE BOARD………….……………………………………….9
- THE HEADREST…………………………………………..……………………………….10
- ATTACHING THE WOBBLE BOARD (CLINICAL/CLINICAL PLUS)………….……….11
- ATTACHING THE TOWERS (CLINICAL PLUS)…………………………………………12
- ATTACHING THE PULLEYS (CLINICAL PLUS)………………….….…………………..14
USING THE PRODUCT …………………………………………………………………………….……….….. 15
MAINTENANCE AND CARE ………………………………………………………………………..………… 18
SUPPORT… ……………………………………………………………………………………….…………….. 19
WARRANTY.……………………………………………………………………………………………….…….. 20
TABLE OF CONTENTS

Page 1
Read all safety information before operating the 2000-1. It is the owner’s responsibility to ensure that users are aware
of all warnings and precautions.
Please read all instructions before using the product. These instructions were written to ensure the safety of the user and to
protect the product.
You should always consult with a physician before beginning a new fitness plan.You are advised to investigate and inform
yourself about any health related actions and choices you make.
Use caution when mounting and dismounting.
Do not allow children to have unsupervised access to the product.
Keep pets away from the 2000-1 at all times.
Perform regular maintenance for optimal performance and longevity. To ensure safety, the 2000-1 must be checked for wear
and damage on a regular basis.
Replace any damaged or worn parts immediately. Do not use the 2000-1 until the repair is performed.
Use only original parts from the manufacturer. Changes or modifications to this unit not expressly approved by Shuttle
Systems could void the warranty.
The 2000-1 is for indoor use only. Do not store the 2000-1 outdoors, near water, or at high humidity levels.
Fully assemble the product before using it. Check the product before each use. Do not continue to use the product if it is
not working.
Use of this product is subject to medical examination to assess your suitability to the type of workout exercise you intend to
perform, and in compliance with the conditions for use laid down by Shuttle Systems.
Persons suffering from certain physical conditions may only use the product under the strict supervision of a doctor with
specific qualifications.
Before starting any workout, make sure your position on the product is correct, paying attention to any components that
may obstruct use.
Plan the workout according to your physical characteristics and state of health, beginning with less demanding workloads.
Do not overexert yourself or work to exhaustion. Incorrect or excessive exercise may cause physical harm or sudden death.
If you feel any pain or abnormal symptoms, stop your workout immediately and consult your physician.
Wear proper workout clothing and shoes during training; do not wear loose clothing. Tie long hair back. Keep hands,
shoelaces, garments, and accessories away from moving parts. Do not insert objects into openings on the equipment.
When using the 2000-1, other people must remain a safe distance.
Do not use the product when children or pets are present.
The person in charge of the gym must explain proper and improper use of the equipment to users.
Assemble and use the product only on a solid and flat surface.
Keep the product in good working condition. If you see signs of wear, contact Shuttle Technical Support Service.
Do not attempt any maintenance work on the product other than the operations described in the user manual.
IMPORTANT SAFETY INFORMATION
PERSONAL SAFETY

Page 2
Dimensions: 31”W x 104”L
Floor Space Required: 3’W x 10’L
Carriage Capacity: 350 lbs
Max Resistance:
2000-1: 12-200 lbs*
Total Elasticords:
2000-1: (8) 12 lb Elasticords
Dimensions: 31”W x 104”L
Floor Space Required: 3’W x 10’L
Carriage Capacity: 350 lbs
Max Resistance:
2000-1: 12-200 lbs*
Total Elasticords:
2000-1: (8) 12 lb Elasticords
KICKPLATE
HEADREST
ADJUSTABLE
PLATE
ELASTICORDS
HANDLES
BACKREST
SLOTTED
PLATE
SLIDER BAR
HANDLES
FOOTREST
KICKPLATE
HEADREST
ADJUSTABLE
PLATE
ELASTICORDS
HANDLES
BACKREST
SLOTTED
PLATE
SLIDER BAR
HANDLES
FOOTREST
ROM
CONTROL
WOBBLE
BOARD
* Elasticords are rated starting
resistance, but will gain
resistance up to 40% in
extension
* Elasticords are rated starting
resistance, but will gain
resistance up to 40% in
extension
SPECIFICATIONS
SPECIFICATIONS (CLINICAL)

Page 3
Dimensions: 31”W x 104”L
Floor Space Required: 3’W x 10’L
Carriage Capacity: 350 lbs
Max Resistance:
2000-1: 12-200 lbs*
Total Elasticords:
2000-1: (8) 12 lb Elasticords
A - Manufacturer’s name and contact
B - Item Number
C - Description of product
D - Serial number
A
B
D
C
HEADREST
BACKREST
ROM
CONTROL
SLOTTED
PLATE
ADJUSTABLE
PLATE
HANDLEBARS
KICKPLATE
TOWERS
ADJUSTABLE
PULLEY
PULLEY
HANDLE
WOBBLE
BOARD
ELASTICORDS
FOOTREST
SLIDER BAR
HANDLES
* Elasticords are rated starting
resistance, but will gain
resistance up to 40% in
extension
SPECIFICATIONS (CLINICAL PLUS)
IDENTIFICATION OF THE MANUFACTURER

Page 4
Assembly of the 2000-1 requires two people.
Tools Needed: 7/16 inch socket or combination wrench, 1/2 inch socket of combination wrench.
Clinical Plus model will also need a rubber mallet for tower installation.
The 2000-1 will come in three boxes:
1. Rails and Carriage
- Carriage
- 2000-1 Rail System
- Kickplate Structure
2. 2000-1 Stands
- Two Stand-Ends
- Connector Bar
- Parts Bag
- Wobble Board w/ Hanger (Clinical/Clinical Plus ONLY)
- Towers (Clinical Plus ONLY)
- Towers Bag (Clinical Plus ONLY)
Head-End Stand
(Head-End)
Kickplate Structure
(Foot-End)
It is important to become familiar with the expressions “Foot-End and Head-End” as they indicate orientation for the
various steps and structures.
2. Kickplate
- Kickplate Board
- Parts Bag
ASSEMBLY OF THE 2000-1

Page 5
ATTACHING STAND ENDS TO CONNECTOR BAR
STEP 1
ITEMS REQUIRED
Stand Ends
Connector Bar
1. Position the stand-ends and crossbar on floor with care. Stand ends across from each other with the support bar in-
between.
2. Remove hardware from the support bar (four washers and four lock nuts). Place one end of the support bar against the
head-end stand, making sure that the bolts on the end of the support bar sit in-between the stand-end and rest against
the stand-end spacer block. (Pic 1.1, 1.2, 1.3)
3. Re-attach hardware to the support bar and hand-tighten to the head-end stand. Repeat this process to attach the foot-
end stand to the support bar. (Pic 1.4 & 1.5)
1.1
1.1
1.2
1.3
1.4
1.5
ASSEMBLY OF THE 2000-1 (STEP 1)

Page 6
ATTACHING 2000-1 RAILS WITH CARRIAGE TO STAND-ENDS
STEP 2
ITEMS REQUIRED
2000-1 Rails
Carriage
Stand-End Assembly
1. Position the carriage and rails so the four bolts fit into the bolt holes on the stand ends. (Pic 2.1)
2. Add washers and hand tighten lock nuts. (Pic 2.2)
3. Check for square alignment of the stand and rails. Nudge the bottom edge of the stand-ends to align. (Pic 2.3)
4. Tighten the eight lock nuts under the rails and on each stand-end. Once tightened add nut caps to all eight lock
nuts.
5. Add handles to the carriage. (Pic 2.4)
Images on next page
ASSEMBLY OF THE 2000-1 (STEP 2)

Page 7
2.2
ATTACHING 2000-1 RAILS WITH CARRIAGE TO STAND-ENDS
STEP 2
2.1
2.3
2.4
ASSEMBLY OF THE 2000-1 (STEP 2)
Inhaltsverzeichnis
Beliebte Medizinische Geräte Handbücher anderer Marken

TekTone
TekTone Tek-CARE160 Bedienungsanleitung

NeuroMetrix
NeuroMetrix Quell 2.0 Bedienungsanleitung

AMT
AMT XLR8 Bedienungsanleitung

Medipost-Nutristoma
Medipost-Nutristoma MD300K2 Bedienungsanleitung

EDAN
EDAN SONOTRAX Pro Bedienungsanleitung

Restorative Therapies
Restorative Therapies RT300 Bedienungsanleitung











