- 2 - Trove2SL2 / TSL2 Installation Guide
Overview:
Trove2SL2 accommodates various combinations of Sielox boards with or without Altronix power supplies and accessories for access systems.
Specifications:
• 16 Gauge grey backplane and enclosure with ample knockouts for convenient access.
Trove2SL2
Trove2 enclosure with TSL2 Altronix/Sielox backplane.
• Includes: tamper switch, cam lock, and mounting hardware.
Enclosure Dimensions (H x W x D): 27.25” x 21.75” x 6.5” (692.15mm x 552.5mm x 165.1mm).
TSL2
Altronix/Sielox backplane only
• Includes mounting hardware.
Dimensions (H x W x D): 25.375” x 19.375” x 0.3125” (644.5mm x 482.6mm x 7.9mm).
TSL2 accommodates a combination of the following:
Altronix Modules:
• Up to two (2) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB, or eFlow104NB.
• One (1) ACM8(CB), ACMS8/ACMS8CB, PDS8(CB), VR6, MOM5, PD4UL(CB), PD8UL(CB), or ACM4(CB).
Sielox Boards:
• Up to eight (8) AC-1700.
Agency Listings:
• UL 294 - 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.
* Stand-by Power Level I if no battery is supplied.
• This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada.
• CE European Conformity.
Installation Instructions for Trove2:
1. Remove backplane from enclosure prior to mounting (do not discard hardware).
2. Trove2SL2 (Pg. 4): Mark and predrill holes on the wall to line up with the top three keyholes in the enclosure. Install three upper
fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws;
level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three
fasteners. Place the enclosure’s upper keyholes over the three upper screws. Install the three
lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent)
in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of
the enclosure approximately 2” from the right side (Fig. 1, pg. 2).
Connect tamper switch wiring to the Access Control Panel input or the appropriate
UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount Altronix/Sielox modules to TSL2 backplane, refer to page 3.
Fig. 1
Tamper Switch
(included)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure