Sonostar CProbe Bedienungsanleitung

Wireless Probe Type
Ultrasound Scanner
CProbe
User's Guide
Prescription Statement “Caution: Federal law restricts this device to sale by or on
the order of a physician”.
A/0

目录
Section 1 INTRODUCTION...................................................................................................................... 1
1.1 Signs and Meaning........................................................................................................................ 1
1.2 TECHNICAL PARAMETERS.......................................................................................................... 2
1.3 INDICATIONS FOR USE................................................................................................................. 2
1.4PRECAUTIONS & WARNINGS....................................................................................................... 2
Section 2 GETTING STARTED.................................................................................................................. 1
2.1 UNPACKING.................................................................................................................................... 1
2.2 INSTALLING APP........................................................................................................................... 4
2.3 STARTING PROBE......................................................................................................................... 7
2.3.1 Visual inspection.......................................................................................................... 7
2.3.2 Probe cleaning................................................................................................................ 7
2.3.3 Boot check........................................................................................................................ 7
2.4 WIRELESS CONNECTION.............................................................................................................. 8
Section 3 APP OPERATIONS................................................................................................................... 9
3.3.2 Patient information input........................................................................................................... 11
3.3.3 Data measurement......................................................................................................................12
3.3.4 Report download..................................................................................................................... 14
3.3.5image and vedio storage......................................................................................................... 15
3.3.5.1 Image storage............................................................................................................ 15
3.3.5.2 Vedio storage............................................................................................................ 16
3.3.6 Image and vedio review......................................................................................................... 16
3.3.7Replace the signal channel..................................................................................................... 16
Section 4 MAINTEANCE........................................................................................................................ 17
4.1 PROBE CHARGING.......................................................................................................................17
4.2 WATERPROOF IPAD................................................................................................................... 17
4.3 CLEANING AND DISINFECTION.................................................................................................18
4.4 STORAGE.......................................................................................................................................18
4.5TROUBLE SHOOTING...................................................................................................................18
4.6Disposal......................................................................................................................................... 18
4.7Proudct maintenance and protection..................................................................................... 19
Section 5 Safety.................................................................................................................................... 20
5.1 Safety Instructions......................................................................................................................20
5.1.2Mechanical Safety................................................................................................................ 20
5.1.3 Accessories Safety............................................................................................................... 21
5.1.4 Cybersecurity.......................................................................................................................21
5.2 Principles of Using Acoustic Power............................................................................................. 22

5.2.1 Biological Safety................................................................................................................. 22
5.2.2 Mechanical and Thermal Indices.........................................................................................22
5.2.3 Acoustic Output Statement.................................................................................................. 22
5.2.4 Operator Control Property................................................................................................... 23
5.2.5 Acoustic Power Settings...................................................................................................... 24
5.2.6 ALARA................................................................................................................................24
5.3 Electromagnetic Compatibilities................................................................................................. 24
5.3.1 Electromagnetic Emission................................................................................................... 25
5.3.2 Electromagnetic Immunity.................................................................................................. 26
5.3.3 Recommended Separation Distance.................................................................................... 27
Appendix A Specifications ....................................................................................................28
Appendix B Acoustic Output Data....................................................................................................... 29

1
Section 1 INTRODUCTION
The Wireless Probe Type Ultrasound Scanner (Model: CProbe) is the new generation
instruments for ultrasonography with the outstanding feature of wireless.
Different with traditional ultrasound scanner with a cable connecting from probe to main unit,
no cable appears at the end of the probe of the Scanners. The probe of the Scanner is highly
integrated with ultrasound image processing, power management and a wireless signal provider to
be connected by the main unit.The main units different with traditional devices are now changed to
be any iPad from Apple Inc or Apple iPhone. The probe acts as a Wi-Fi Access Point and can be
connected by iPad or iPhone. With the probe be connected through WiFi and the App is running,
enjoy your days of working without the trouble making cables.
This manual is intended to provide a thorough overview of the Scanner and should be carefully
read before starting operating the device.
Thank you for your trust in us to provide for your ultrasonography needs.
Figure 1.1 CProbe Wireless Probe Type Ultrasound Scanner
1.1 Signs and Meaning
Sign
Meaning
Caution! Please consult the accompanying document.
Consult the user manual
Type BF applied part
Degree of IP protection
Non-ionizing electromagnetic radiation
Manufacturer
Date of manufacture
Serial number

2
Keep dry
IPX5
Prevent the water from the nozzle from invading in all directions and cause damage to
the electrical apparatus.
1.2 TECHNICAL PARAMETERS
Display: iPad / iPhone Series
Gray Scale: 256 levels
Battery last: > 3 hours
Size: 104mm x 50mm x 22mm
Weight: ≈308g
Operations
Storage and Transportation
Relative Humidity
25% to 80%,
non-condensi
ng
25% to 93%, non-condensing
Ambient Temperature
5°C to +40°C
-20°C to +55°C
Atmospheric Pressure
700hPa to
1060hPa
700hPa to 1060hPa
Electronic:
Input:5Vd.c. 1A
Battery Capacity:modle(SNP-4200)3.8Vd.c. 4200mAh
continuous working time:2hour
Waterproof: IPX5
1.3 INDICATIONS FOR USE
The Wireless Probe Type Ultrasound Scanner (Model: CProbe) is intended for diagnostic ultrasound
echo imaging, measurement, and analysis of the human body for general clinical applications
including obstetrics (OB), gynecology (GY) and general (abdominal) imaging.
1.4PRECAUTIONS & WARNINGS
PRECAUTION 1: Read the user manual carefully before operating the device, be familiar with
the equipment and operation procedures, and strictly implement; the company is not
responsible for the damage caused by the improper use of the machine and the resulting
potential adverse consequences;
PRECAUTION 2: The instrument must work in a clean environment, should avoid direct sunlight,
extreme temperature changes, dust, near heat sources, high humidity places, do not place
anything on top of the instrument.
PRECAUTION 3: The device shall be operated in undisturbed conditions so as to avoid data
transmission interruption.
PRECAUTION 4: When there is wireless channel congestion, switch the channel (Refer to
Section 3.6 SETTINGS), and then restart the probe.
PRECAUTION 5: Prescription Use. The device shall be operated by professional physicians.
PRECAUTION 6: The device shall be repaired by professional recognized by the manufacturer.

3
PREACUTION 7: The device does not have shelf life. Its expected use lifeis 10 years. After 10
years, though the device still works normally, it is recommended to have it checked by the
manufacturer.
PRECAUTION 8: Useless components shall be disposed according to local regulations.
PRECAUTION 9: Be careful when holding the device, for the device is handheld, it may fall.
PRECAUTION 10: Pay attention: the words “Insufficient Storage Space”will appear on the
interface to remind the user to clean up space when storage space will be insufficient.
WARNING 1: The device is not explosion-proof. Do not use it in inflammable and explosive
environment (such as in the presence of anesthetic gas, oxygen or hydrogen,etc.);
WARNING 2: Instrument is not waterproof, do not spill water or other liquids on the
instrument.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Changes or Modifications not expressly approved by the party responsible could void the user’
s authority to operate this device.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement

1
Section 2 GETTING STARTED
FOR YOUR PROTECTION, please read these safety instructions completely before applying
power to, or operating the system.
2.1 UNPACKING
The Scanner is carefully packed to prevent damage during shipment. Before unpacking, please
note any visible damage to the outside of the shipping containers.
Items should be checked in order to ensure that all ordered items have been received. The
following table lists the items which should be received with each particular system.
Table 2-1 Items List for The Wireless Ultrasound Scanner
Each item should be examined for any noticeable defects or damage that may have occurred
during shipment although it is packed carefully. If any defect or damage exists, please contact your
local representative immediately to report the problem.
Caution
Too high ultrasonic intensity and / or long exposure time
may cause injury.
Please do not apply the probe of this machine to the scope
not covered in this manual.
ITEMS
INCLUDED
Host(Including probe)
√
Manual
√
USB charging cable
√
Warranty Card
√
Power Adapter
Optional
Tablet
Optional

2
On Off/ freeze
Under probe working status display
Wireless signal status
Battery capacity
display
Upper probe working status display
display
Product schematic diagram
Picture 2-1 L-probe
Picture 2-2 C-probe
Picture 2-3 double head
Wireless signal status display
display
Wireless signal status display
display
Probe
On Off/ freeze
Battery capacity
display
Probe
On Off/ freeze
Battery capacity
display
CT-probe CL-probe

3
Switch the probe: press and hold the switch for three seconds
Working state display: indicator lamp indicates the position of the convex array to work
with the convex array probe, and indicator linear array position to work with the linear
array probe
Charging support: this probe only supports wireless charging.
Picture 2-4 C-probe&L-probe
Picture 2-5double head(CT-probe&CL-probe)

4
2.2 INSTALLING APP
The software is installed by computer after connecting iPad or iPhone to computer.
Before software installation, please make sure your computer has installed the Apple iTunes.
And please copy the wireless scanner Application to the computer disk. There are two separate
applications, one for IPAD, another for IPHONE.
1) Connect the IPAD or IPHONE to your computer, Open iTunes, Choose File menu, marked with
Red border.
Inhaltsverzeichnis
Andere Sonostar Scanner Handbücher