ST DELTA SOLAR Bedienungsanleitung

True RMS Digital meter
Clamp
User Manual
DELTA SOLAR


DELTA SOLAR
(20)
(21)
ON
(22)
ON
(9)
(19)
(17)
(8)
(16)
(18)
(14)(10)(15)
(12)
(13)
(11)

1
Contents
(1) Liquid crystal display
(2) ON / OFF pushbutton
(3) Pushbutton for data hold and
MIN/MAX storage functions
(4) Pushbutton for manual range
selection
(5) Multi-function pushbutton
(6) Function selector switch
(7) Terminal sockets
(8) Symbol for “CONTINUOUSLY
ON”
(9) Display for digits, decimal point
and polarity.
(10) Display for manual range
selection, DATA HOLD and
MIN/MAX storage
(11) Display for selected function
(12) Display for the unit of measured
quantity
(13) Overrange indication for positive
analog range.
(14) Pointer for analog indication
(15) Scale for analog indication
(16) Over range indication for
negative analog range
(17) Low battery indicaton
(18) Buzzer indication
0
(19) Display for C for temperature
measurement range.
(20) Rotary mechanism for clamp
jaws.
(21) Safe trigger mechanism.
(22) Limit of safe access for hand held.
1. Introduction........................................................................2
2.
Safety features and safety precautions..............................2
3.
Switching the Clamp meter ON.........................................3
4.
Function and range selection............................................4
4.1
Autoranging.......................................................................4
4.2
Manual range selection.....................................................4
5. Liquid crystal display..........................................................5
5.1 Digital Display....................................................................5
5.2
Analog indication...............................................................5
5.3 Backlit ...............................................................................5
6.
“DATA” hold facility ...........................................................6
7. Minimum value and maximum value “MIN/MAX” storage
facility.................................................................................6
8. Voltage measurement........................................................9
8.1 Voltage measurement on electrical systems up to 1500 V
DC and 1000 V AC with the HV 30 measuring adapter.....9
9. Resistance measurement ................................................11
10.
Diode test and continuity test............................................11
11. Temperature measurement .............................................12
12. Capacitance Measurement..............................................12
13. Frequency Measurement ................................................13
14. Duty cycle Measurement ................................................13
15. Current Measurement .....................................................14
16.
Empty Positions..............................................................16
17.
Specifications..................................................................17
18.
Maintenance ...................................................................21
18.1
Battery ............................................................................21
18.2
Periodic Check-up :........................................................22
19. Servicing............... ..........................................................22

2
2. Safety features and safety precautions
Please note the following safety precautions:
You have chosen a Clamp meter which provides you a very high degree of
safety. The digital Clamp meter / Digital multimeter manufactured and tested in
compliance with the safety standard IEC 61010-1:2010.
In case of incorrect use or careless handling, the safety of both user and clamp
meter are not assured.
For proper use and safe handling, it is absolutely necessary to read and
understand the operating instructions before using the clamp meter.
The clamp meter must be operated only by persons who understand
the danger of shock hazards and are aware of the necessary safety
precautions. Shock hazards exist wherever voltages of more than
30V(TRMS)are present.
Do not work alone in shock hazardous environment while carrying
out measurement.
The maximum permissible voltage between any of the terminal
sockets (7) and ground is 1000V AC and 1500V DC.
T ake into account that unexpected voltages can occur on devic e
under test(e.g.defective instrument). For example, capacitors may
be charged to a dangerously high voltage.
Verify that the test leads are in good condition, i.e. no crac ked
insulation, no open circuits in the leads or connectors.
This clamp meter must not be used for measurements on circuits with
corona discharge (highvoltage).
composite voltages may exist there.
Be particularly careful when measuring on HF circuits. Dangerous
Measurements under moist environmental conditions are not permitted.
For safe voltage measurements in power systems
1500V DC, we recommend the
HV 30 measuring adapter, which is
available as an accessory.
Its internal resistance limits the measuring current in the case of
overvoltage, incorrect operation and safely suppresses sparking
from spark gap. Also refer to Section "8.1 Voltage measurement
on electrical systems up to
1000V AC and 1500V DC
with HV 30
Do not overload the measuring ranges beyond their allowable
capacities. Limit values are given in specifications. Ref. Chapter 16.
Please verify the performance of clamp meter after repairing
of the meter, before using it for actual measurement.
Do not use the clamp meter if obvious wear in jaw opening
is visible.
Protection provided by the digital clamp meter may be impaired if
the clamp meter is not used in a manner
manual.
specified in this user
Operators must use individual protective equipment if
hazardous live parts of installation could be accessible.
Keep hands/fingers behind the edge that separates rotating
jaws with hand held part(22). This is the limits of the hand
held part during measurement.
1. Introduction:
Thank you very much for selecting We are leading manufacturer
of Electrical and Electronics state-of-art measuring instruments.
These clamp meters are manufactured as per IS 13875 and DIN 43751.
Clamp Meter.
1000V AC &
upto
measuring adapter ”.

3
Meaning of the symbols on the device
Warning of a danger point
(Attention, refer to the user
manual)
Earth (ground) terminal.
Double or reinforced insulation
Instrument for over voltage
category III OR IV
CAT III/IV
Meaning of the acoustic signals
Intermittent acoustic signal: Voltage limit exceeded; for Voltage>1000V AC
Intermittent acoustic signal: limit exceeded; for >1600A
1)
2) Current Current
Repair , replacement of parts:
When opening the meter, live parts may be exposed. Therefore, the
meter must be disconnected from the measuring circuit prior to opening
its case for repair or replacement of parts. If repair cannot be avoided
unless the meter is opened and live, this work must only be performed
a qualified person who understands the danger involved.by
Faults and abnormal stress:
When it is realised that the safe operation is no longer possi
meter out of service and secure it against accidental use. Safe operation
may not be possible,
lwhen the meter shows obvious signs of damage.
lwhen the meter no longer functions correctly.
lafter prolonged storage in adverse conditions.
ldue to severe stress during transportation.
ble, take the
3.
ccording to
Battery".
Switching the Clamp meter "ON”
Battery
We have already fitted your meter with a 9V flat cell battery a IEC
6 F22 or IEC6LR61. It is ready for operation. meter for
the first time or after storage, refer to Section "18.1 Maintenance-
Before you use the
Meaning of categories and their significance per IEC61010 -
CAT I:
connected to the mains: for example electrical systems in motor vehicles
and aircraft, batteries etc.
CAT to the
low-voltage mains: with plugs, e.g. at home, in the office or laboratory etc.
CAT III:
consumers, distributor terminals, devices connected permanently to the
distributor
CAT IV:
m
1
Measurements in electrical circuits
which are not directly
II: Measurements in electrical which are electrically connected
Measurements in building installations, stationary power
Measurements at power sources for low-voltage installations,
eters, mains terminals, primary over voltage protection devices.
and Voltage>1500V DC

4
Disconnect the clamp meter from the measuring circuit before
you open it, and see section "18. Maintenance".
Automatic TURN-OFF
The meter turns off automatically, when the measured value remains
constant (variations of the measured value < + 2digits) for about 10
minutes and when neither a pushbutton nor the function selector switch is
operated during that time.
How to prevent automatic TURN-OFF
In order to prevent automatic "TURN OFF" select "CONTINUOUSLY
ON" mode. For this, press
yellow
multi-function pushbutton (5) and the
"ON/OFF" pushbutton (2)together. The function "CONTINUOUSLY ON"
is shown on the LCD(1) by the symbol (8).
Turning the multimeter OFF
Press the "ON/OFF"pushbutton (2).
4. Function and range selection
ON
4.1 Autoranging
The multimeters feature autoranging for all measuring ranges with the
exception of the 30mV ,300mV ranges. Autoranging is
automatically selected after switching the multimeter ON. According
to the measured quantity applied, the multimeter automatically selects
the measuring range which gives the best resolution. When switching to
The meter switches automatically to:
the next highe range
r at + (3099 digits+1digit)
the next lower range at + (240/280 digits-1digit)
4.2 Manual range selection
You can switch OFF autoranging and select the ranges manually
according to the table on the following page.
Manual mode is switched OFF when push button AUTO/MAN is pressed (4)
for approximately 1s, when the function selector switch (6) is operated,
or when the meter is turned OFF and ON again.
When switching back to autoranging from 30mV or 300mV ranges,
3 V range is automatically selected.
frequency measurement and ratio measurement the previously selected
voltage measuring range is maintained.
Switching the meter "ON"
Note:
Electric discharges and high-frequency influence may cause incorrect
information to be displayed and block the measuring process.
meter by switching it OFF and ON again otherwise, check the battery
connections.
Press the "ON/OFF" pushbutton (2).
Switch-"ON" is acknowledged by a sound signal. As long as you
keep the pushbutton pressed, all segments of the liquid crystal display
(LCD) will appear. The LCD is shown behind cover page
After the push button is released, the meter is ready for operation.
Reset the

5
5. Liquid crystal display
5.1 Digital display
The digital display (9) shows the measured value with correct location of decimal
point and sign. The selected measuring Unit(12)and the function(11)
are simultaneously displayed. When measuring DC quantities, a minus sign
appears in front of the digits, when the positive pole of the measured
quantity is applied to the" "input terminal. When upper range limit 3099
(on the range :1999),is exceeded then"OL"is displayed.
With V and Ω measurements, the digital display is updated two times
per second.
5.2 Analog indication
The analog indication with pointer presentation gives the dynamic
response of a moving-coil movement and is updated 20 times per second,
when measuring V and
Ω. Analog indication is of particular advantage
when observing variations of measured values and for calibration
procedures.
The analog indicator has its own polarity indication. When measuring
DC quantities, the analog scale(15) has a negative range of 4 scale
divisions so that variations of the measured values around" zero"canbe
observed exactly. When the measured value exceeds the range of
indication, the left triangle(16) is shown before the polarity of the analog
indicator switches over after approximately 0.7s.The over range indication
on the measuring range(>3099 digits,on the range >1999)is shown
by the right triangle(13).
The instrument is provided with user selectable Backlight for taking
measurements in poor lighting conditions/darkareas.
Switching the Backlight ON
By pressing "AUTO/MAN"and"HOLD" keys simultaneously
the Backlight can be switched ON.
Switching the Backlight OFF
By pressing "AUTO/MAN" and "HOLD" keys simultaneously
the Backlight can be switched OFF.
F30 nF 300 nF 3 μF30 μF30 nF...
Hz 300 Hz 3 KHz 30 KHz 100 KHz 300 Hz...
300A 1500A 300A...
A , A
1500V
5.3 Backlight (Optional)

6
6. Data
“HOLD”
facility
The HOLD function allows to automatically hold the measured values.
The meter holds the measured value on the digital display with a sound
signal and displays “ HOLD ” on LCD display (10). The probes or clamp
measuring point and the measured value
on the digital display(9) can be read.
The analog indication
is not influe-
HOLD.
The
actual measured value
can
still be noted/read. Note that with
a held digital display, the location of the decimal point is a lso held.
With autoranging selected, the measuring range of the analog indicator
Note: Hold function is not available in function and 30 mV and 300
mV
As long as the data HOLD function is active,manual range selection
is not possible.The data HOLD function is switched OFF, when
7. Minimum value and Maximum value "MIN / MAX"
storage facility.
With the MIN/MAX function,you can hold the minimum and the maximum
measured value which was applied to the input of the
Clamp Meter
after
activating MIN/MAX function.The most important application is
the
determination of the minimum and the maximum value for long-term
monitoring of measured quantities. MIN/MAX does not influence the
analog indication The actual measured value can still be noted/read.
Apply the measured quantity to the meter and select the measu ring
range prior to activating the MIN/MAX function.
With the function activated, you can select the measuring ranges
manually, if you switch to another range, the stored MIN/MAX values are
cleared.
The “HOLD”
pushbutton(3) is pressed for approx.1s.This is
acknowledged by 2 sound signals.
The function selector switch(6)is operated or
The multimeter is turned OFF and ON again.
is no
longer known.
ranges in function .
V
0C
To activate “HOLD” function momentarily, press the HOLD key.
can now be removed from the
nced by the data

Function
MIN/MAX
2xShort,
30mV/
300mV
and
0
C
1xshort
short
short
Short
Long
DATA
MIN/MAX
(3)
Measured
Values
MIN and MAX
Stored
Storage Continued
in the background,
new MIN/MAX.
values are displayed
Same as 1.
Stored Values
are not cleared
Cleared
actual
meas-
ured
value
stored
MIN
value
stored
MAX
value
same
as1.
Cleared
MIN
and
MAX
flash
MIN
MAX
same
as1.
Cleared
Meter acknowledgement
Display
MIN
MAX
Meas-
uring
ranges
Sound
Signal
1.
Activate and
Store
2.
Store and
display
3.
Return to 1.
Reset
1 x
1 x
1 x
1 x
2 x
Meas.
Value
digital
V
Ω
V ~ A- - -
Ω
Same
as1.
0
C
0
C
A~ A- - -
A ~
, ,%F
,Hz
, ,%F
,Hz
The MIN/MAX function is switched OFF
, when the MIN/MAX push b
utton
(3) is pressed for approximately 1s, or when the function sel ector switch
(6) is operated, or when the meter is turned OFF and ON again.
7
Inhaltsverzeichnis
Andere ST Messgerät Handbücher

ST
ST VA8041 Bedienungsanleitung

ST
ST UM2898 Bedienungsanleitung

ST
ST Beta 20P Series Bedienungsanleitung

ST
ST DELTA 1000/400A AC DC Bedienungsanleitung

ST
ST N30U Bedienungsanleitung

ST
ST STPM01 Bedienungsanleitung

ST
ST CAYMAN 401 Bedienungsanleitung

ST
ST STDES-BLUEPLUG2 Bedienungsanleitung

ST
ST STEVAL-IPE007V1 Bedienungsanleitung