3. All installaons to which the device is connected should comply with
the regulaons applicable in the country of installaon and use.
4. It must be ensured that the circuit in the electrical installaon to
which the radiator is connected has an appropriate overcurrent cir-
cuit breaker and a residual current device (R.C.D.) with a sensivi-
ty of 30 mA. With the permanent (hard-wired) installaon it is also
mandatory to have an omni polar cut-o for disconnecng the de-
vice on all poles, by points of contact with the clearance of 3 mm.
5. The device version labelled PB can be installed in bathrooms, but at
least 1m from any water source, PW version with the plug can be
installed in dry areas only, (as dened by applicable law, subject to
any addional regulaons concerning electrical installaons in wet
areas).
6. Do not use extension cords or adapters for electrical outlets to plug
the product.