Title Page
1. INTRODUCTION ..............................................................................1
2. FEATURES.......................................................................................2
3. SPECIFICATIONS............................................................................2
4. PARTS & CONTROLS.....................................................................4
4-1 Description of Parts & Control keys............................................4
4-2 Description of Display.................................................................8
5. OPERATING INSTRUCTIONS.......................................................10
5-1 Setting the Calibration Factor...................................................10
5-2 luminous Flux Measurement ....................................................11
5-3 Maximum & Minimum Recording Measurement ......................12
5-4 Hold Function Operation...........................................................12
5-5 Zero Iunction Operation............................................................13
5-6 Ratio Function Operation..........................................................13
5-7 ZERO-Ratio Function Operation ..............................................15
5-8 Ratio – ZERO Function Operation............................................15
5-9 Sort Function Operation............................................................16
5-10 Comparator Setting and Operation.........................................17
5-11 Manual Data Memory and Read Mode...................................18
5-12 Auto Datalogging Function......................................................19
5-13 RS232 Communication...........................................................20
5-14 To Disable Auto Power off Function.......................................21
6. BATTERY CHECK-UP &
&&
&REPLACEMENT..................................21
7. SPECTRAL SENSITIVITY CHARACTERISTIC.............................21
8. MAINTENANCE..............................................................................22
9. RS-232 INTERFACE, SOFTWARE INSTALLATION AND
OPERATION...................................................................................22
※
※※
※
Copyright ©
2009 TES Electrical Electronic Corp. All rights reserved.

1
1. INTRODUCTION
The meter is an easy-to-use, precision photometric meter
designed for use in the field, laboratory, or production floor. The
meter measures luminous flux from source such as LED’s, small
lamps, and fibre-illuminators. The meter features a 75mm
diameter integrating shpere that collects the total light entering
the sphere measurement port.
The integrating is the ideal optical device for measuring luminous
flux from a source placed inside the sphere or just outside the
sphere sample port.
It meets CIE photopic spectral response, f ’
1
≦6%.
The meter is compact, tough and easy to handle owing to its
construction.
The light sensitive component used in the meter is a very
stable, long-life silicone photo diode and spectral response filter.
Measure LED’s, small lamps, and fibre-illuminators.
Measure narrowband and broadband sources.
Measure highly divergent sources.
Reduced sensitivity to light source alignment.
Reduced sensitivity to polarization.
Omits error introduced from detector area non-uniformities.
U.S. Pat. No. Des. 446,135
Taiwan Pat. No. M 342502

2
2. FEATURES
Easy-to-read 4 digit LCD display.
Spectral Sensitivity close to CIE photopic Curve.
Measuring Level Range: 0.05 to 7000 lumens, Autoranging 4 steps.
Accurate and Instant response.
Data Hold function.
Auto Data Hold function.
Data memory and read function.
Maximum / Minimum function.
Zero function.
Ratio function.
Sort function.
Comparator function.
Auto power off function.
Auto datalogging & RS-232 interface.
3. SPECIFICATIONS
•Display :4 digit LCD reading.
•Measuring Range : 9.999, 99.99, 999.9, 7000 lumens
(Autoranging 4 steps)
•Resolution : 0.05 – 9.999 0.001 lumen
10.00 – 99.99 0.01 lumen
100.0 – 999.9 0.1 lumen
1000 – 7000 1.0 lumen
•Accuracy:0.05 to 0.1 ±7%, 0.1 to 1000 ±2%, 1000 to 7000 ±3%
•Overange Display : LCD will show “OL” symbol.
•Spectral Response : CIE Photopic.
(CIE human eye response curve).

3
•Spectral Accuracy : CIE Vλfunction f ’
1
≦6%
•Integrating Sphere : Diameter : 75 mm
Material : BaSO
4
Sample Port : 25 mm dia.
•Photo Detector : One silicone photo diode and spectral response
filter.
•Temperature Characteristics :±0.1% / ºC.
•Sampling Rate : 5 times/sec.
•Manual Data Memory Capacity :999 sets.
•Auto Datalogging Capacity : 38000 sets.
•Operating Temperature & Humidity:
0ºC to 50ºC(32ºF to 122ºF)& 0% to 80% RH.
•Storage Temperature and Humidity:
-10ºC to 60ºC(14ºF to 140ºF)& 0% to 70% RH.
•Power Source :6 pcs size AAA battery.
•Battery life ( typical ) : 100 hours ( carbon zinc ).
•Integrating Shpere Lead Length : 80 cm ( approx. ).
•Integrating Shpere Dimensions : 94(D) ×108(H) mm
•Meter Dimensions : 150L×72W×35H (mm);
•Weight :470g .
•Accessories :Carrying case, instruction manual, batteries,
software CD rom & RS232 cable, Port Adaptor kit.

4
4. PARTS & CONTROLS
4-1 Description of Parts & Control keys
17
13
133
15
1
2
3
5
6
14
8
11
10
12
9
7
4
ZERO RATIO
18
16
AVGMAX MIN
ZERO
1. LCD Display :4 digit display with a maximum of 9999 readings
and the indicating signs of measured values, unit function symbols
and decimal points etc. are displayed.
2. Power Control key:The power switch key turns the meter
ON or OFF.
3. key :
1Press key to display the Maximum (MAX), Minmum
(MIN) and Current (MAX MIN) measured values, press this key
for 3 seconds to exit this mode.
2In the READ mode, press key to display the manual
memorized data value of Maximum (MAX), Minimum (MIN),
and Average (AVG), if the manual memorized data all are
measured in the same mode.

5
4. Data-Hold key :
1Press key to hold data, the D-H annunciator is displayed,
press this key again to exit this mode.
2Press key for 3 seconds to enter the auto hold mode, the
A-H annunciator is displayed, press key for 3 seconds to
exit this mode.
3Press and hold down key, then press key to turn on
the meter, the auto power off function will be disabled, and the
auto power off symbol “ ” will be disappear.
5. key : Press key to enter the zero mode, the
“ZERO” annunciator is displayed, press this key again to exit
this mode.
6. key : Press key to enter the setting mode, press
key to exit this mode.
1Press key to setting the sort tolerance limits.
2Press key to setting the comparator High / Low values.
3Press key to setting the auto datalogging interval time.
4Press key to setting the calibration factor value.
5Press key to setting the reference value.
7. key : Press key to enter the ratio mode, the “RATIO”
annunciator is displayed, press this key again to exit this mode.
8. key :
1Press key to enter the sort mode, the “SORT”
annunciator is displayed, press this key again to exit this mode.

6
2Press key first then press key to enter the sort
tolerance limits setting mode.
9. key :
1Exit a setting mode or store the displayed setting.
2Exit the READ and Auto datalogging mode.
10. key :
1Press key to enter the comparator mode, the COMP
annunciator is displayed, press this key again to exit this mode.
2Press key first then press key to enter the
comparator value setting mode.
11. key :
1Press key one time to store one set LCD reading to
memory.
2Press key for 3 seconds to enter or exit auto
datalogging mode.
3In the reference value setting mode and the comprator value
setting mode, press ⊳key to move the decimal point left to the
desired position.
4Press and hold down key then press key to turn on
the meter to enter the clear manual and auto memorized data
mode.
5Press key first then press key to enter auto
datalogging interval time setting mode.
12. key :
1Press key to enter the read mode, the R annunciator is
displayed, press key to exit this mode.

7
2Press key for 3 seconds to turn on the RS232 interface.
3In the reference value setting mode and the comprator value
setting mode, press key to move the decimal point right to
the desired position.
13. key :
1In the setting mode press key to increase the setting value.
2In the READ mode press key to increase the memory
location.
3Press key first then press key to enter the
calibration factor setting mode.
14. key :
1In the setting mode pess keyto decrease the setting value.
2In the READ mode press keyto decrease the memory
location.
3Press key first then press key to enter the SORT
and RATIO reference value setting mode.
4Press key to display the reference value, press this key
again the reference value is disappeared.
15. Integrating sphere.
16. Port Adaptor kit :
2mm Adaptor size.
3mm Adaptor size – (T1)
4mm Adaptor size
5mm Adaptor size – (T1-3/4)
8mm Adaptor size
10mm Adaptor size – (T3-1/4, T3-3/4)
24mm Adaptor size
17.AC adaptor socket (9V, 100mA).
18.RS232.

8
4-2 Description of Display
RATIO
ZERO
AVG
ZERO
MINMAX
: Auto power off indication.
ZERO : Zero mode indication (φ= φ
in
–φ
d
)
ZERO RATIO : Zero – Ratio mode indication
[RATIO = (φ
in
– φ
d
)/ (φ
R
– φ
d
)]
RATIO : Ratio mode indication (RATIO = φ
in
/ φ
R
)
RATIO ZERO : Ratio – Zero mode indication
[RATIO = (φ
in
– φ
d
)/ φ
R
]
D-H : Display data hold mode indication.
A-H : Display Auto data hold mode indication.
SET : Setting mode indication.
SET SORT 10% : Sort tolerance limits setting mode indication
(10% to 100%).
SET 1.100 lumen : Comparator High limit value setting
indication.
SET 0.900 lumen : Comparator LOW limit value setting
indication.
SET INTV
.
1 A-M : Auto datalogging interval time selection
mode indication (1, 2, 3, 4, 5, 6, 7, 8, 9, 10,
20, 30, 40, 50 seconds or 1, 2, 3, 4, 5, 6, 7,
8, 9, 10, 20, 30, 40, 50, 60 minutes).
Inhaltsverzeichnis
Andere TES Messgerät Handbücher

TES
TES TES-1362 Bedienungsanleitung

TES
TES 593 Bedienungsanleitung

TES
TES TES-3600 Bedienungsanleitung

TES
TES 46 Bedienungsanleitung

TES
TES TES-1353S Bedienungsanleitung

TES
TES TES-593R Bedienungsanleitung

TES
TES TES-1304 Bedienungsanleitung

TES
TES 1352H Bedienungsanleitung

TES
TES 1370 Bedienungsanleitung

TES
TES TES-1358 Bedienungsanleitung