VWF Series Vented Gas Log Set
Please leave these instructions with the appliance.
Please retain these instructions for future reference
.
1. The installation, combustion and ventilation air
must conform with local codes or, in the absence of
local codes, with the National Fuel Gas Code, ANSI
Z223.1.
2. Installation and repair should be done by a qualied
service person. Vermont Castings Group Vented Gas
Logs must be installed only in a masonry or a UL 127
solid-fuel replace with minimum venting requirements,
see installation section.
3. To prevent malfunction, gas log set and ue should
be cleaned at least annually by a professional service
person. More frequent cleaning may be required due
to excessive lint from carpeting, etc. It is imperative
that control compartments, burners and circulating air
passageways be kept clean.
5. Never burn solid fuels in a replace where a gas log
set is installed.
6.
A replace screen must be
in place when the log set is burning. Provisions for
adequate combustion air must be provided. Adequate
combustion air usually results in all ames curling into
the replace away from screen and up the ue.
8. Keep room area clear and free from combustible
materials, gasoline and other ammable vapors and
liquids.
9. Children and adults should be alerted to the hazard
of high surface temperature and should stay away to
avoid burns or clothing ignition.
10. Young children should be carefully supervised when
they are in the same room with the gas log set in opera-
tion.
11. Do not place clothing or other ammable material near
the replace when the gas logs are in use.
12. Do not use this gas log set if any part has been under-
water. Immediately call a qualied service technician
to inspect the gas logs and replace any part of the
control system and any gas control which has been
under water.
13. The gas log set
must be isolated from the gas supply
piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 psig (3.5kPa).
14. Secure gas log set to replace.
15. This log set will burn off the paint on the front grate
bar.
16.
Installation of this vented gas log in the Commonwealth
of Massachusetts requires the damper be permanently
removed or welded in the full open position. In addition, a
naturally vented gas log may not be installed in a bedroom
or bathroom in the Commonwealth of Massachusetts. Flex
line installation must not exceed 36".