Viavi SmartClass MPOLS-84 Bedienungsanleitung

MPOLS-84 (P)
MPOLS-85 (P)
MPOLP-85 (P)
SmartClass™ Fiber
Multifiber Light Source
Multifiber Power Meter
Operating manual
BN 2329/98.21
2019.12
English

Please direct all inquiries to your local Viavi sales company. The
addresses can be found at:
www.viavisolutions.com/en-us/contact-sales-expert
A description of additional instrument features can be found at:
www.viavisolutions.com/en-us/products/network-test-and-certification
Notice
Every effort was made to ensure that the information in this document
was accurate at the time of printing. However, information is subject to
change without notice, and Viavi reserves the right to provide an
addendum to this document with information not available at the time
that this document was created.
General Public License
This product includes Qt 4.8.3 software licensed under the GNU LGPL
v. 2.1, and barebox 2012.02.0 and linux 3.1.0-rc8 software licensed under
the GNU GPL v. 3. To request a copy of the source code for this software,
please write to:
Open Source Request • Viavi Legal Department •
430 N. McCarthy Blvd. • Milpitas, CA 95035 USA
Copyright
© Copyright 2019 Viavi Solutions Inc. All rights reserved. Viavi and the
Viavi logo are trademarks of Viavi Solutions Inc.
All other trademarks and registered trademarks are the properties of
their respective owners.
Viavi Solutions Deutschland GmbH
Arbachtalstraße 5, D-72800 Eningen u. A.
Order no.: BN 2329/98.21
Version: 2019.12
Previous version: 2019.06
Notes
Changes may be made to specifications, descriptions, and delivery
information.

MPOLx-84/85 (P) 3
CONTENTS
CONTENTS
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Enterprise Structured Cabling Workflow. . . . . . . . . . . . . . . . . 6
MPOLx-84/85 (P) MPO Test Sets . . . . . . . . . . . . . . . . . . . . . . . 7
MPOLS-85/P Light Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operating manual update. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Symbols used in this operating manual . . . . . . . . . . . . . . . . 10
SAFETY INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Warning symbols on the unit . . . . . . . . . . . . . . . . . . . . . . . . . 13
Proper usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Laser safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Battery operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
PS4 Universal AC/DC Power Supply . . . . . . . . . . . . . . . . . . . 14
GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Unpacking the instrument. . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
BASIC OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Switching the instrument on/off . . . . . . . . . . . . . . . . . . . . . . 24
Operator control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Menus and display elements . . . . . . . . . . . . . . . . . . . . . . . . . 25
Navigating in the menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Displaying application information . . . . . . . . . . . . . . . . . . . . 31
Changing System Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
WiFi menu (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Bluetooth menu (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Installing a software option . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Updating the firmware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Creating screenshots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
MANAGING PROJECTS . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Test-Tool mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Workflow mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

4 MPOLx-84/85 (P)
CONTENTS
LOSS/LENGTH TEST OPERATION . . . . . . . . . . . . . . . . . . . 45
General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Adjusting general test settings . . . . . . . . . . . . . . . . . . . . . . . 46
Defining a test configuration . . . . . . . . . . . . . . . . . . . . . . . . . 47
Polarity Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Referencing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Running a test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Referencing and running a test with 24 fiber cabling . . . . 56
Viewing test results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Saving test results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
SOURCE OPERATION (MPOLS) . . . . . . . . . . . . . . . . . . . . 65
Measurement display overview . . . . . . . . . . . . . . . . . . . . . . . 65
Selecting a wavelength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Selecting and deselecting fibers . . . . . . . . . . . . . . . . . . . . . . 66
Changing fiber output manually . . . . . . . . . . . . . . . . . . . . . . 66
Activating auto fiber output. . . . . . . . . . . . . . . . . . . . . . . . . . 67
Switching the laser on/off. . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
POWERMETER OPERATION (MPOLP) . . . . . . . . . . . . . . . 68
Selecting the measurement mode . . . . . . . . . . . . . . . . . . . . 68
Selecting a wavelength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Selecting the display mode . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Activating the peak hold function . . . . . . . . . . . . . . . . . . . . . 68
Showing the measured values in graphic mode. . . . . . . . . 69
Relative measurement mode . . . . . . . . . . . . . . . . . . . . . . . . . 69
Absolute measurement mode . . . . . . . . . . . . . . . . . . . . . . . . 70
Pass/fail measurement mode. . . . . . . . . . . . . . . . . . . . . . . . . 71
Saving Powermeter test results . . . . . . . . . . . . . . . . . . . . . . . 72
PROBE/PCM OPERATION . . . . . . . . . . . . . . . . . . . . . . . . 74
General information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
The build in Patch Cord Microscope (PCM). . . . . . . . . . . . . 74
The external P5000i Digital Probe . . . . . . . . . . . . . . . . . . . . . 75
Basic settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Selecting a profile and adapter/tip . . . . . . . . . . . . . . . . . . . . 79
Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Saving Probe/PCM results . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
WORKFLOW MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Performing a measurement in Workflow mode . . . . . . . . . 84
If a test has failed / repeating a test . . . . . . . . . . . . . . . . . . . 88
Managing Workflow projects . . . . . . . . . . . . . . . . . . . . . . . . . 89

MPOLx-84/85 (P) 5
CONTENTS
DATA MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Saving results. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Selecting test results in Test-Tool or Workflow Mode . . . . 90
Data management of Loss/Length tests. . . . . . . . . . . . . . . . 90
Data management of Powermeter tests. . . . . . . . . . . . . . . . 92
Data management of Probe and PCM tests . . . . . . . . . . . . 94
Exporting results to USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Making a report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Cleaning the test port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Cleaning the instrument . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
ENVIRONMENTAL COMPLIANCE . . . . . . . . . . . . . . . . . . . . . 99
REMOTE CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
ORDERING INFORMATION . . . . . . . . . . . . . . . . . . . . . . . 102
MPOLx-84/85 (P) stand alone units. . . . . . . . . . . . . . . . . . . 102
Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Included items. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Software options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Digital Probe Microscope . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
General specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Loss/Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Power Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Light Source. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Patch cord microscope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107

6 MPOLx-84/85 (P)
1 INTRODUCTION
ENTERPRISE STRUCTURED CABLING WORKFLOW
1INTRODUCTION
Enterprise Structured Cabling Workflow
With Enterprise Structured Cabling Workflow (ESCW) Viavi
provides an integrated workflow environment for planning,
distributing, performing, collecting, and evaluating
measurement procedures of fiber infrastructures.
ESCW consists of three components:
• Project Management Application
• Mobile Application
• Measurement instrument (e.g. MPOLx-84/85 (P))
The cloud workflow overview
- Creates label lists
- Creates/modifies/selects test profiles
- Creates tasks (label lists + test profiles)
- Creates project and assigns project team
- Assigns tasks to project team members
- Control progress
- Analyses test results
- Provides test reports
Project manager Project manager / Consultat /
Cabling vendor
- Connects mobile app to instrument
- Configure instrument from mobile app
- Store results if not connected to cloud
- Adds further note, e.g. pictures, videos
Technician
Technician
- Connects to SUT and performs all tests
- Changes configuration if needed
- Saves results to instrument
- Adds notes to results
Project Management
Application (Cloud)
Mobile
Application
Measurement
Intruments
Tasks pushed to mobile app
Tasks transfered to instrument Results transfered to mobile app
Upload results to cloud

MPOLx-84/85 (P) 7
1 INTRODUCTION
MPOLX-84/85 (P) MPO TEST SETS
Project Management Application
The Project Management Application is a cloud- and browser-
based application that allows a project manager to control the
entire measurement process:
• Define enterprise specific workflows
• Assign tasks
• Develop label templates
• Set up test profiles
• Analyse results
• Manage crews
When finally set up tasks can be assigned to a field technician
and provided via the cloud platform.
NOTE: For further information about the Project Management
Application please refer to the help provided with the application.
Mobile Application
The Mobile Application allows the field technician to download
assigned tasks from the cloud platform (push service) and to
transfer the task to the measurement instrument.
After completing the tasks the results can be uploaded via the
Mobile Application to the Project Management Application on
the cloud platform for further analysis.
NOTE: For further information about the Mobile Application please refer
to the help provided with the application.
Measurement instrument
Measurement instruments that support ESCW (...) offer beneath
the test application centric Test-Tool mode a Workflow mode.
This Workflow mode allows the use of the ESCW functions like a
structured, guided, and pass/fail-oriented execution of projects
assigned to a specific field technician.
For key benefits of the Workflow mode see “Workflow mode” on
page 8.
MPOLx-84/85 (P) MPO Test Sets
The MPOLx-84/85 (P) test sets consist of two test units:
•MPOLS-84/MPOLP-85, MPOLS-85/MPOLP-85
The MPOLS-84/MPOLP-85 test set (for Multi-mode) and
MPOLS-85/MPOLP-85 test set (for Single-mode) consist of a

8 MPOLx-84/85 (P)
1 INTRODUCTION
MPOLX-84/85 (P) MPO TEST SETS
high-performance, easy-to-use
MPO light source and a MPO
power meter for measuring up to 12 fiber simultaneously. In
a single run polarity, length and loss can be measured fast and
reliable. The results are displayed either in an overview for
quick check or in detail for a deeper evaluation. The results can
be saved for later use.
•MPOLS-85P/MPOLP-85P, MPOLS-84P/MPOLP-85P
The MPOLS-85P/MPOLP-85P test set - while offering the
identical features as the MPOLS-85/MPOLP-85 test set - are
additionally equipped with a Patch Cord Microscope (PCM) to
view and inspect (male or female) patch cord fiber connectors.
Key Benefits of the Test Sets
Test-Tool mode
• Test application centric approach.
• Achieve complete network certification with the MPOLx-84/85
(P).
• Optimize productivity with the industry’s fastest test workflow.
• Obtain comprehensive results for the latest TIA 568.3,
ISO 11801, and ISO 14763-3 requirements.
• View test setup and results data at both local and remote
instruments.
• Objective pass/fail testing for fiber end-face requirements.
Workflow mode
• Label list centric approach.
• Guided testing of large number of equal test points with
predefined tests.
• Visual display of measurement progress.
• Quick overview of passed and failed test.
Features
• Multi-mode (850/1300 nm) and single-mode (1310/1550 nm)
adapters for Tier 1 fiber certification (loss/length/polarity).
• Industry-leading P5000i Digital Probe fiber end face
inspection probe support.
• Measuring 24 fiber cables (with optional Y-adapter cable).

MPOLx-84/85 (P) 9
1 INTRODUCTION
MPOLS-85/P LIGHT SOURCES
MPOLS-85/P Light Sources
The MPOx MPOLS-85/P light sources are professional, versatile,
compact handheld instruments designed for qualification and
certification of fiber optic networks. Carefully chosen
combinations of available wavelengths make MPOx MPOLS-85/
P light sources the optimum choice for link loss testing and
characterization of long-haul, metro, and access
telecommunication networks, as well as for data center and local
area network testing.
Single-mode (SM) or multi-mode (MM) –
The perfect solution for your need
Light sources are available as single-mode (MPOLS-85/P) and
multi-mode (MPOLS-84/P) devices. Just choose the device that
fits your needs. These instruments are particularly suitable for
rental and measurement service companies.
Fiber inspection ready – Inspect before you
connect
The MPOx MPOLS-85 instruments are prepared for fiber
inspection. Connection of a P5000i Digital Probe to the MPOLS-
85 enables a technician to perform best practices fiber
inspection and automated Pass/Fail testing of optical
connectors/adapters in order to ensure industry standard fiber
end face quality and cleanliness. No additional fiber microscope
set required – simply plug in a P5000i Digital Probe.
Report generation – Do it the easy way
Of course, it is possible to make measurement reports with a PC
tool. FiberChekPRO™ is the ideal tool for generating your report.
Please download FiberChekPRO™ for free on
http://updatemyunit.net/index2.php.
Rugged and portable
Battery operation with AA dry batteries, AA NiMH rechargeable
batteries, or with a rechargeable Li-Ion Battery Pack ensures a
long operating time in the field and a robust, shock-proof design
makes the MPOx instruments the perfect choice for optical
network field testing, even under tough conditions.

10 MPOLx-84/85 (P)
1 INTRODUCTION
OPERATING MANUAL UPDATE
Remote controllable
Operation with an AC/DC power supply and remote control
capabilities via USB 2.0 and Ethernet make the MPOx
instruments a perfect solution even for fixed installations in
central offices, in production environments, and on the
laboratory workbench.
Operating manual update
Continuing enhancement and further development of the MPOx
family implicates that this operating manual might not cover all
the latest functions of your instrument.
If the operating instructions about features supported by your
instrument are missing, please visit the Viavi web site to check if
additional information is available.
To download the latest user manual:
1. Visit the Viavi web site at http://scf.updatemyunit.net.
2. Select your MPOx model from the product line.
3. Open the download area and download the latest user
manual.
Symbols used in this operating manual
Various elements are used in this operating manual to draw
attention to special meanings or important points in the text.
Symbols and terms used in warnings
The following warnings, symbols, and terms are used in this
document in compliance with the American National Standard
ANSI Z535.6-2011:
NOTICE
Follow the instructions carefully to avoid damage to or
destruction of the instrument.
Dieses Handbuch passt für folgende Modelle
5
Inhaltsverzeichnis
Beliebte Kabeltester Handbücher anderer Marken

Radiodetection
Radiodetection RD8100 Bedienungsanleitung

Vonaq
Vonaq EasyCheck 900 Bedienungsanleitung

Softing
Softing CableMaster CM200 Bedienungsanleitung

Microtest
Microtest 8751 Bedienungsanleitung

Psiber Data Systems
Psiber Data Systems 20 Bedienungsanleitung

Platinum Tools
Platinum Tools LANSeeker TP500C Bedienungsanleitung