wirsbo FlowMaster Bedienungsanleitung

Wirsbo FlowMaster™User Manual

Wirsbo FlowMaster™ User Manual
is published by Uponor Wirsbo
5925 148th Street West
Apple Valley, MN 55124
(952) 891-2000
© 2003 Uponor Wirsbo
All rights reserved
First Edition
First printing, March 2003
Printed in the United States of America

Table of Contents
1
1
Wirsbo FlowMaster User Manual
Table of Contents
Section 1 Overview ....................................................................................................................3
Section 2 Key Functions ............................................................................................................4
Section 3 Setup Menu ............................................................................................................5-7
Section 4 Flow Meter Menu ......................................................................................................8
Section 5 Flow and Temperature Measurement ..................................................................9
Section 6 Reading Memory ....................................................................................................10
Section 7 Deleting Memory ....................................................................................................11
Section 8 Connecting to a Computer ....................................................................................12
Section 9 Charging the Battery ..............................................................................................13

2
Wirsbo FlowMaster User Manual

Section1 —Overview
1
3
Wirsbo FlowMaster User Manual
Section 1 — Overview
The Wirsbo FlowMaster™ uses superior technology to measure flow and temperature in radiant floor
heating systems. Using infrared light, the hand-held electronic instrument reads the flow and
temperature for each loop — resulting in accurate and quick balancing or troubleshooting.
Even in highly contaminated water, the FlowMaster remains efficient by recalibrating the measures
according to the water transparency.
The companion electronic flow meter nipple easily measures
the flow by guiding the FlowMaster tool into the correct
measuring position — ensuring flawless data readings.
The FlowMaster comes with a
Microsoft Windows-compatible
software package, allowing the
ability to download data for
record keeping. Software
upgrades are available on
the Wirsbo website.
FlowMaster offers
superior accuracy
and efficient
measuring and data
collection at an
affordable price.

4
Wirsbo FlowMaster User Manual
Section2 —Key Functions
2
The FlowMaster features five key functions.
1. Power on/off key [ON/OFF]
2. Left key allows user to quit a function. [LEFT]
3. Right key allows user to select function or
confirm choice. [RIGHT]
4. Up key allows user to move up in pop-up
menus. [UP]
5. Down key allows users to move down in
pop-up menus. [DOWN]
1
5
2
4
3
Figure 2-1 Wirsbo FlowMaster
Section 2 — Key Functions
FlowMaster Package Contents.
• FlowMaster instrument
• Temperature/flow probe
• Charger
• PC download cable
• Software CD

5
Wirsbo FlowMaster User Manual
Section3 —Setup Menu
3
WIRSBO
➜SETUP
FLOW METER
➜TEMP. ADJUST
FLOW ADJUST
To turn on the FlowMaster, press [ON/OFF] for a minimum
of two seconds.
When the start menu appears, press [UP] or [DOWN] to
select SETUP. Press [RIGHT] to confirm this choice and to
enter SETUP mode.
The display shows the measured temperature at the
sensor. If the temperature reading is not correct, the
temperature displayed can be adjusted. Adjust the
temperature by pressing the [UP] or [DOWN] key.
Save the selected value by pressing the [RIGHT] key.
To delete the adjustment, press the [LEFT] key.
Each instrument is factory calibrated. If the temperature
needs to be recalibrated, Wirsbo recommends doing so
only with the use of a certified instrument.
Press the [UP] or [DOWN] key to cycle through the
following functions.
•Temperature adjustment • Backlight
•Flow adjustment • Auto off
•Measuring units • Version
•LCD contrast
Select the appropriate function by pressing [RIGHT].
TEMP 70.0ºF
CANC OK➜
➜
Temperature Adjustment
Turning on Power
The following appears in the display.
In SETUP mode, the following appears in the display.
Section 3 — Setup Menu
Note: Before using the FlowMaster for the first time, charge the battery for a minimum of
14 hours.

6
Wirsbo FlowMaster User Manual
BACKLIGHT 5.0S
CANC OK➜
➜
Section 3 —Setup Menu
3
➜1/m HARDWARE:
GPM ALL VALVE
LCD CONTRAST 5
CANC OK➜
➜
The flow-adjustment operation may be necessary in older
radiant floor systems when the water or the sensing ports
of the electronic flow meter nipple darkens due to dirty
water in the system.
The self-calibration requires the electronic flow meter
nipple to remain in a 100% open position (maximum flow)
to obtain an accurate reference point.
On the manifold system, close all valves except the one used for the calibration process.
Attach the probe securely to the electronic flow meter nipple and press [RIGHT] to start the
calibration. The display will return to the previous menu when the calibration is completed.
Press [LEFT] to cancel flow adjustment step.
When the instrument powers off, the FlowMaster returns to the default calibration typically
used in new installations.
To select the appropriate MEASURING UNIT, press the
[UP] or [DOWN] button. Save and quit by pressing
[RIGHT]. To quit without saving, press [LEFT].
This setting remains in memory even if the FlowMaster
powers off, but can be changed any time through the
SETUP menu.
To select the LCD CONTRAST value, press the [UP] or
[DOWN] button. The value range is 1 to 9. Confirm the
setting by pressing [RIGHT], or cancel the value by
pressing [LEFT].
Use the [UP] or [DOWN] button to adjust the BACKLIGHT
duration (idle time). The duration range is 1 to 12.5
seconds. Save the value by pressing [RIGHT], or exit
without saving by pressing [LEFT].
FLOW ADJUST
EXIT START➜
➜
Flow Adjustment
Measuring Units
LCD Contrast
Backlight

7
Wirsbo FlowMaster User Manual
Section3 —Setup Menu
3
AUTO OFF
CANC OK➜
➜
BATTERY LEVEL
■■■■■■■■
FIRMWARW: 1.21EN
HARDWARE: D005_2
To set the AUTO OFF time, press the [UP] or [DOWN]
button. The auto-off time range is 15 to 90 minutes.
Save the auto-off time range by pressing [RIGHT], or exit
without saving by pressing [LEFT].
The battery level is indicated in the display. Exit this menu
by pressing [LEFT].
The VERSION menu displays the firmware and hardware
versions.
For the most recent information, download updates from
the Wirsbo website (www.wirsbo.com).
Exit the VERSION menu by pressing [LEFT].
Auto Off
Version
Battery Level

8
Wirsbo FlowMaster User Manual
Section4 —Flow Meter Menu
4
Figure 4-1 Connecting the Probe
SET UP
➜FLOW METER
Turn the power on (see page 5),and select Flow Meter
from the menu by pressing [UP] or [DOWN]. Confirm the
choice by pressing [RIGHT].
Starting to Measure
➜FLOW/TEMP.
PRESSURE
The FLOW & TEMPERATURE PRESSURE menu appears.
Section 4
—
Flow Meter Menu
Before turning the FlowMaster on, connect the
flow/temperature probe. Only connect the probe
while the FlowMaster is turned off. Make sure
that the probe is aligned correctly and the nut
tightened. See Figure 4-1.
Move the pointer through the following menu functions using the [UP] or [DOWN] key.
•Flow & Temp. (Flow and temperature measuring)
•Pressure (Differential pressure measuring)
•Read memory (Accessing stored measurements)
•Delete (Erasing stored measurements)
•Transf. mem➞PC (Transferring stored data to a computer)
Select a function by pressing [RIGHT].