With the continuous development of clinical nutrition, how to accurately and comprehensively
evaluate the nutritional status of individuals, better implement clinical nutrition support treatment, and
promote early recovery, has been paid more and more attention by the general population. In recent
years, the rapid development of human composition determination methods can provide important
clinical nutritional information for assessing the nutritional status of the human body. On the one hand,
it can be used to prevent epidemic diseases such as obesity, and on the other hand, it can guide the
administration of reasonable diet and exercise. Bioelectrical impedance technology (BIA) is a
detection technology that extracts the electrical impedance information of the organism to reflect the
biomedical information related to the physiology and pathology of the organism. The human body
composition analysis is an important application branch of bioelectrical impedance technology, it is
through the detection of human body impedance information to get the parameters of each component
of the human body. Human body composition analyzer is simple, accurate, non-invasive, safe, low
cost and a wide range of people and other advantages, whether it is academic and commercial, have
been vigorously developed.
Thank you for purchasing the Intelligent Body Composition Analyzer.
Copyright 2021 by Shenzhen Yolanda Technology Co.,Ltd.
Rev.1.0
Printed in 08/05/2021.

Catalogue
一、Product Overview ......................................................................................................................................................... 1
二、Description of warning and error sign or signal ............................................................................................................ 1
三、Safety Precautions......................................................................................................................................................... 1
四、Product introduction ..................................................................................................................................................... 3
五、Structure and component .............................................................................................................................................. 4
六、APP Operation Instructions .......................................................................................................................................... 8
七、Packing list.................................................................................................................................................................. 12
八、Battery Installation/Replacement ................................................................................................................................ 12
九、Cleaning/disinfection and Care ................................................................................................................................... 12
十、Trouble-shooting ......................................................................................................................................................... 13
十一、Standard List ........................................................................................................................................................... 13
十二、Disposal .................................................................................................................................................................. 14
十三、EMC ........................................................................................................................................................................ 14
十四、Warranty and warranty information ........................................................................................................................ 18
十五、Manufacturer and European Authorized Representative Information .................................................................... 19

1
一、Product Overview
The Body Composition Analyzer mainly through the measurement of body weight, bioimpedance and height,
age, gender set to calculate the body's BMI, body fat rate, body water and other indicators; In addition, the data can
be directly uploaded to APP via Bluetooth or to server via WiFi connection, and then the server will push the data to
APP to generate in-depth test report. The body composition analyzer is suitable for individuals, family users and
other long-term monitoring of body obesity, to provide data reference for weight loss and muscle gain.
To ensure proper use, please be sure to read this user manual carefully, paying close attention to the safety
precautions.
In order to use this product correctly, please read the user manual before use.
In order to properly use this product, please carefully read the full text of this manual before using, in particular
the“safety precautions”section.
Please keep this instruction manual in a convenient place for reference.
二、Description of warning and error sign or signal
1.Warning instructions and precautions
The warning signs and graphic symbols in the manual are intended to enable you to use the product safely and
correctly and to prevent harm to you and others. Warning marks and graphic symbols are described as follows:
Warning/precautions symbols
Waring
Indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
cautions
Means a possibility of personal injury or property damage in case of
improper use.
Notes
Indicates the need for attention, if not attention may lead to incorrect use
of the product or property device damage.
2.Symbol description
Manufacturer information:
The manufacturer name and
address
Manufacture date
Serial Number
Batch code
Pile Limit 4 layers
Authorized representative
in the European
Community.
Refer to instruction manual. Medical device
Applied part of type BF Fragile,handle with care

2
Keep Dry
The product should be
vertically up
1639
Complies with the European Medical Device Regulation(2017/745.Notified
Body is 1639.
Disposal in accordance with Directive 2002/96/EC(WEEE)
三、Safety Precautions
Warnings
1、Use object
·The target users of this product are the general population aged 18-60.
2、Potential safety hazards and use restrictions
·Concurrent use of this device and implantable medical electronic instruments,e.g.Cardiac Pacemaker.
·Concurrent use of this device and wearable medical electronic instruments,e.g.electrocardiograph.
·Concurrent use of this device and other medical electronic instruments for life support,e.g.mechanical heart.
·Slippery floor such as tile floor.
·Jumping onto the platform immediately after bath or with wet hands.
·Interference may occur in the vicinity of equipment marked with the following symbol .And the Analyzer
may interfere vicinity electrical equipment.
·No modification of this equipment is allowed. There is a risk of electrocution or injury. Nor can precise analysis
be guaranteed.
Any modification without permission is prohibited as such modification may result in unacceptable risks.
The maintenance of the equipment must be conducted by special personnel. Disassembly and maintenance of
the machine by oneself is prohibited. (Circuit diagram, list of components, drawing notes, calibration details and
other information have been provided to maintenance personnel.)
Cautions
Avoid storage in the following locations:
·Where there is water
·Where the device may be exposed to extreme temperatures, humidity, moisture, direct sunlight, dust, or salt air
·Where there is risk of shock or drop
·Where you store chemicals or full of corrosive gases
·Where in reach of the infants or children
·To enable the data transmission function, this product should be paired to a Bluetooth end at 2.4 GHz.
·Do not carry out maintenance or maintenance during use

3
四、Product introduction
1.Intended use
1.1 The Body Composition Analyzer measures weight, body impedance and uses bioelectrical impedance
analysis(BIA)technology to estimate body fat percentage(body fat mass), total body water content, BMI in generally
healthy adults. The visceral fat rating and protein are only displayed on the APP.
1.2 It is intended for use in the home only.
2.Efficacy
2.1 This product is simple to use, and requires no specialized facilities or expertise to take measurements.
2.2 Measurements can be taken quickly and easily, causing minimal inconvenience to the patient during.
measurements.
3.Contraindication
3.1 This device is contraindicated for any female subject who may be suspected of, or is pregnant.
Besides provided inaccurate readings, the affects of this device on the fetus are unknown.
3.2 This device is contraindicated for any person who is connected to a wearable or implantable electronic device
or instrument such as a pacemaker or defibrillator.
4.Specifications
Product name Body Composition Analyzer
Model CS20C
Measurement Principle bioelectrical impedance analysis(BIA)
Weight measurement range 0.2-180kg
Pressure starting weight >5kg
Accuracy 0-50kg,0.2kg;50-100kg,0.3kg;100-150kg,0.4kg;150-180kg,0.5kg
Resolution ratio 0~100k
g
:0.05k
g
;>100k
g
:0.1k
g
Memory Capacity 20
Number of users 8
Power source 4*1.5V AAA battery
Size 310*310*25mm
Net weight 1.8kg(including battery)
EMC I、Class B
Degree of protection against
electric shock
Type BF applied part
Working Environment
Temperature :5℃~40℃ 41℉~104℉
Humidity :30-90%RH
Atmospheric Pressure :70kPa-106kPa
Transportation and Storage
Environment
Temperature :-40℃-55℃ -40℉~131℉
Humidity :0-93%RH (No condensation)
Atmospheric Pressure :70kPa-106kPa
Applicable period 3 years
Manufacture date/Lot number See fuselage and gift box for details

4
5.Wireless technology
The specification of wireless transmission
For Bluetooth:
Bluetooth 5.0
Valid Transmission Up to 10 meters
Receiver Bluetooth 4.0 enabled smart phones running android 4 and
above system version and iPhone 4s and above
Signal transmission 2.4G Bluetooth
Frequency 2.402-2.480 GHz
Bluetooth
Modulation Type
GFSK
For Wi-Fi:
Transmission type Wi-Fi
Val id
Transmission(Distance
between Wi-Fi APP and
Body Composition
Analyzer)
Up to 50 meters
Frequency Range 2412~2462MHz
Wi-Fi APP running
environment
Enable smart devices running android 4 and above system
version and iPhone 4s and above
WIFI Modulation Type BPSK/QPSK/16QAM/64QAM/DBPSK/DQPSK/CCK
五、Structure and component
1. External component
2. Display

5
3. Product performance
a. The products are mainly composed of shell, glass, display screen, battery, weight test module, body fat test
module, Bluetooth module, WiFi module and mobile terminal application software。
b.Product basic information display description

6
4、Basic information
This product can measure body weight, fat percentage, BMI and other indexes. After the measurement is
completed, the data will be transmitted to the mobile terminal application software through Bluetooth 4.0 or WiFi.
1、Measurement method

7
Place in a hard and flat place for use, do not use on uneven soft materials (such as: soft floor, carpet or spring
pad, etc.), otherwise it can not be measured correctly.
• Do not place in direct sunlight, near heating equipment, air outlet of air conditioning
• Do not use in places with drastic temperature changes
• Do not place it in a humid or steamy place
Body fat percentage is obtained by the BIA bioreactance measurement, which is closely related to the following
parameters: body resistance coefficient/height/weight/age/sex. So change any one of these parameters and the fat
percentage changes.
Also please do not measure under the following conditions:
• After strenuous exercise
• After a bath or sauna
• After overeating
• After drinking a lot of water or alcohol
• Cold and fever
The body weight changes daily with the change of eating and drinking water, there are 0.5~2KG of the change
value. Since body fat percentage = fat weight/body weight, fat percentage also fluctuates, as shown in the figure
below. In the morning, before eating and drinking, body fat percentage peaks throughout the day, and in the afternoon
and evening, body fat percentage peaks throughout the day as weight gain and water content increase due to eating
and drinking.
3、Measuring position
Inhaltsverzeichnis