Argos Technologies EVac Bedienungsanleitung

Operator’s Manual
Argos Technologies, Inc.
Toll Free: 800-886-8675
International:
847-622-0456
www.argos-tech.com
manufacturing solutions for science
™


2
Argos Technologies EVac™ — Operator’s Manual
2
Table of Contents
Contents ..........................................................................2
ImportantSafetyInformation......................................................3
OperatingConditions..............................................................3
HazardWarningsUsed.............................................................3
ProductOverview .................................................................4
FrontView.........................................................................4
RearView..........................................................................5
ProductDescription ...............................................................6
PackageContents..................................................................6
WarrantyInformation..............................................................7
RepairService .....................................................................7
GettingStarted....................................................................8
OperatingEVac™...................................................................9
Preparingwithoutlevelsensing....................................................9
PreparingVacuumBottle ..........................................................9
ConnectingVacuumBottletoInstrument ..........................................9
Connecting Vacuum Bottle to HandEvac™ Handheld Aspirator . . . . . . . . . . . . . . . . . . . . . . 9
Preparingwithlevelsensing ......................................................10
PreparingVacuumBottle .........................................................10
ConnectingVacuumBottletoInstrument .........................................10
Connecting Vacuum Bottle to HandEvac™ Handheld Aspirator . . . . . . . . . . . . . . . . . . . . . 10
Connecting the Level Detection Sensor Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
PoweringUp......................................................................11
SwitchingOn.....................................................................11
Operation........................................................................12
LevelDetection...................................................................13
CalibratingLevelDetection .......................................................13
Maintenance,CareandSafetyPrecautions.........................................14
Maintenance .....................................................................14
Care..............................................................................14
Autoclaving ......................................................................14
Troubleshooting(FAQ)............................................................15
TechnicalData....................................................................16
AccessoriesandSpareParts.......................................................17

3
Argos Technologies EVac™ — Operator’s Manual
Always use this product in accordance with these instructions. Where appropriate, please use
safety goggles and protective clothing.
Operating Conditions
Operating Temperature 10 - 40° C (50 - 104° F)
Relative Humidity 10 - 90% (no condensation)
Altitude 0 - 2,500M (1.55 Miles)
Important Safety Information
STOP
CAUTION
Indicates possible damage to the instrument. Comply with the instructions.
i
Hazard Warnings Used
DANGER
Indicates possible danger of personal injury or death. Comply with the instructions.
DANGER Biological Risk
Indicates possible biological risk. Comply with the instructions.
NOTE
Provides important notes on the correct operation of Argos Technologies EVac™
Vacuum System.

4
Argos Technologies EVac™ — Operator’s Manual
Product Overview
Front View
1. EVac™ Instrument.
2. Control for Setting Vacuum/Suction Power.
3. ON/OFF Switch.
4. Vacuum Bottle.
5. Bottle Lid.
6. HandEvac™ Handheld Aspirator.
7. Quick Couplings.
8. Level Detection Sensor Cable.

5
Argos Technologies EVac™ — Operator’s Manual
Product Overview
Rear View
9. Socket for Cable Mains Adapter.
10. Push-Button for Level Detection Calibration.
11. Socket for Level Detection Sensor Cable.
12. Connection for Filter Missing if Needed.
13. Air Outlet.
14. Power/Illumination LED Indicator.
NOTE
If the level detection is not in use, items 10 and 11 have no function.
i

6
Argos Technologies EVac™ — Operator’s Manual
Product Description
Thank you for your recent purchase of the Argos Technologies EVac™ Vacuum System.
•The EVac™ is a vacuum system with an integral pump and adjustable, electronic
vacuum controller for laboratory use.
•The instrument should not be used for applications other than those specified.
Package Contents
•EVac™ Vacuum System.
•Universal Power Supply with US, UK, EU and SAA adapters.
•Warranty Registration Card.
•Instruction Manual.
•Tubing Set with Filter.
•Level Detection Sensor Cable (EV300 & EV310).
•4 Liter Polypropylene Bottle or Glass Bottle
•Lid for 4 Liter Polypropylene Bottle with Quick Couplings and Level Detection
(EV310), Lid with Barbed Fittings (EV320) or Lid for Glass Bottle with Quick
Couplings and Level Detection (EV418)
•HandEvac™ Hand Operator

7
Argos Technologies EVac™ — Operator’s Manual
Warranty Information
The Argos Technologies EVac™ Vacuum System is warranted to be free of defects
in materials and workmanship for a period of 12 months from date of purchase,
provided that:
•The unit has not been opened or attempted to be opened by the end user
•The user ensures that it has been carefully cleaned and decontaminated
•The unit has been operated according to the instructions and not in any improper way
In order to qualify for warranty repair, customer must return warranty card supplied with
unit that includes all information required to validate proof of purchase. Should warranty
service be required, repair or replacement will be provided by Argos Technologies without
charge. Freight charges for shipping unit to Argos Technologies will be responsibility of
purchaser. There are no other warranties of application or merchantability.
Repair Service
Should the EVac™ require service or repair, please contact Argos Technologies Customer
Service. A Return Authorization Number will be issued and customer will be advised on
proper packing and method of shipment.
Customer Service:
Within US: 800-886-8675
Outside US: 847-622-0456
Please include RA Number on shipping label.
Please use the same contact numbers for Argos Technologies Technical Support.

8
Argos Technologies EVac™ — Operator’s Manual
Getting Started
Please ensure that all packaging materials have been removed before using the EVac™.
Place the EVac™ unit on a dry, level, dust-free location.
Power supply connection
•Attach the mains adapter with the primary adapter appropriate to the power outlet.
•Plug the mains adapter into a standard electrical source and connect to the EVac™.
DANGER
The supply voltage must comply with requirements listed in the “Technical Data”
section (see page 16).

9
Argos Technologies EVac™ — Operator’s Manual
Operating EVac™
Preparing without level sensing
Preparing Vacuum Bottle
•Fit lid with barbed tube fittings onto bottle. Ensure that lid is firmly attached.
Connecting Vacuum Bottle to Instrument
•Twist filter onto connection on EVac™. Writing on filter should point away from
device. Twist filter until resistance is felt, then twist an additional half turn to ensure
that an adequate seal is achieved.
•Connect filter with short tube to the barbed tube fitting marked “PUMP” on lid of the
vacuum bottle.
Connecting Vacuum Bottle to HandEvac™ Handheld Aspirator
•Connect long tube from HandEvac™ or other suction tool to barbed tube fitting
marked “HAND” on lid of vacuum bottle.
Inhaltsverzeichnis
Andere Argos Technologies Laborausrüstung Handbücher
Beliebte Laborausrüstung Handbücher anderer Marken

Agilent Technologies
Agilent Technologies 5800 ICP-OES Bedienungsanleitung

Endress+Hauser
Endress+Hauser Cleanfit CPA875 Bedienungsanleitung

NI
NI PXI-5422 Handbuch

Collomix
Collomix Aqix Bedienungsanleitung

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series Bedienungsanleitung

Ocean Insight
Ocean Insight FLAME-NIR+ Bedienungsanleitung

Parker
Parker ALIGN-MG-NA Bedienungsanleitung

BD
BD 644787 Bedienungsanleitung

DENTAURUM
DENTAURUM Compact Megaplus Bedienungsanleitung

Biuged Laboratory Instruments
Biuged Laboratory Instruments BGD 626 Bedienungsanleitung

VWR
VWR SAS Super IAQ Bedienungsanleitung

illumina
illumina MiSeqDx Bedienungsanleitung