Dado Lab QB1 Bedienungsanleitung

ENGLISH | I
Constant ow sampler
QB1
User manual
English - 05/2020 - rev1.7 www.dadolab.com

II | QB1 User Manual

ENGLISH | III
Table of Contents
1 General information 1
Receiving goods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Warranty Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Warranty Exclusions / Limitation . . . . . . . . . . . . . . . . . . . . . 1
Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Sampling Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Workplace atmospheres . . . . . . . . . . . . . . . . . . . . . . . . . 2
Stack Emission . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Precautions for humidity . . . . . . . . . . . . . . . . . . . . . . . . . 3
The supply includes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Parts identication 4
Connections panel QB1 V1.5 - V3.0 . . . . . . . . . . . . . . . . . . . . . . 4
Connections panel QB1 V5.0 . . . . . . . . . . . . . . . . . . . . . . . . . 5
Connections panel QB1 V1.5DC . . . . . . . . . . . . . . . . . . . . . . . . 6
Connections panel QB1 V2x5DC. . . . . . . . . . . . . . . . . . . . . . . . 7
Controls panel QB1 V1.5 - V3.0 - V5.0 . . . . . . . . . . . . . . . . . . . . . 8
Controls panel QB1 V1.5DC . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Controls panel QB1 V2x5DC QB1-D . . . . . . . . . . . . . . . . . . . . . . 10
3 Timer setup 11
Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Pump manual ON / OFF . . . . . . . . . . . . . . . . . . . . . . . . . . .11
How to program timed sampling . . . . . . . . . . . . . . . . . . . . . . . 11
4 Thermometer 12
5 Dry Gas Meter 13
Readings and normalization of the volumes . . . . . . . . . . . . . . . . . . 13
6 Leak check - QB1 V5.0 14
Sampling line leak check. . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Leak check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

I| QB1 User Manual
7 QB1-D 15
Dilution sampler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Flowrates denition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
The sampling owrates depends on tubes used: . . . . . . . . . . . . . . . . 15
Calculate dilution owrate . . . . . . . . . . . . . . . . . . . . . . . . 15
8 Maintenance 18
Replace the protection lter . . . . . . . . . . . . . . . . . . . . . . . . . 18
Vacuum leak check . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Liquid removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
This procedure lists the steps necessary to remove liquids accidentally entered
into the QB1 sampler and trapped in the suction protection device.. . . . . . 19
It is recommended to replace the protection lter at the suction inlet. . . . .19
Side panel opening . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Tank emptying . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
9 Technical specications 20
Characteristics and accuracy of the measures. . . . . . . . . . . . . . . . . . 20
Volume. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Ball ow meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Dry gas meter temperature . . . . . . . . . . . . . . . . . . . . . . . . 20
Suction pressure drop (excludingV2x5DC model) . . . . . . . . . . . . . . 20
Specic characteristics for each model. . . . . . . . . . . . . . . . . . . . . 21
QB1 V1.5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
QB1 V3.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
QB1 V5.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
QB1 V1.5DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
QB1 V2x5DC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
QB1 -D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Information on the WEEE (RAEE) symbol. . . . . . . . . . . . . . . . . . . . 24
Proper disposal of the product (electrical and electronic waste) . . . . . . .24

ENGLISH | V

ENGLISH | 1
1 General information
Receiving goods
Remove the packaging and verify the corrispon-
dence to the order and the integrity of the content.
In case of damaged package, immediately note it on
the delivery paper the courier will ask you to sign as
receipt, without the note, no refund from insurance
or replacement will be accepted. In case of evident
damage, you can also refuse the delivery, always with
written notication on the courier documents.
Damages occured after unpacking the goods, must
be notied within 8 days (D.D.T) with written
comunication to the courier and considering them
responsible for any possible consequence.
Test
Test and calibration are done at Dado Lab’s facility,
at the end of it, a report is produced and includ-
ing results and acceptability verication for all the
executed tests.
To request a test at your place, please contact your
local dealer.
Warranty Conditions
Warranty cover the instrument for 12 months from
the delivery/test of the goods.
Disposable/rechargeable batteries have a warranty
of 6 months.
Consumable materials, like components which have
to be replaced periodically during the lifetime of the
instrument (protection lters, fuses or lamps) are
not covered by the warranty.
Warranty Exclusions / Limitation
Dado Lab cannot be considered responsible for any
damage or aws caused by external factors, acci-
dental damages, unproper uses, modication on any
part, transformation, use of non original parts, negli-
gency or lost of the instrument during the delivery
of the instrument.
e warranty will not cover any repair or job which
is not done by Dado Lab or authorized dealer. e
responsability is, in any case, limited to the value of
the purchased instrument.
In case of malfunctioning, please contact:
service@dadolab.com

2| QB1 User Manual
Conformity
Safety and CE mark
Dado Lab declares the instrument is in compliance
with the following standard:
Low voltage instruments directive BT 2014/35/UE
Directive 2011/65/UE ROHS - Restriction of
Hazardous Substances Directive
Directive EMC 2014/30/UE for the electro-mag-
netic compatibility (EMC)
Machinery Directive 2006/42/EC
Sampling Methods
Dado Lab declares that the instrument is compli-
ant to the following standards and methods for the
sampling.
Workplace atmospheres
UNI EN ISO 13137:2015
Pumps for the sampling of chemical agents with a
volume ow rate of over 5 l/min. Requirements and
test methods
Stack Emission
UNI EN 13284-1:2017
Stationary source emissions – Determination of low
range mass concentration of dust – Part 1: Manual
gravimetric method.
UNI EN 1911
Stationary source emissions - Determination of
mass concentration of gaseous chlorides expressed
as HCl - Standard reference method
UNI EN 14385
Stationary source emissions – Determination of the
total emission of As, Cd, Cr, Co, Cu, Mn, Ni, Pb,
Sb, Tl and V
UNI EN 13211
Stationary source emissions. Manual method of
determination of the concentration of total mercury
CEN/TS 13649:2014
Stationary source emissions. Determination of the
mass concentration of individual gaseous organic
compounds. Activated carbon and solvent desorp-
tion method.
Environment
UNI EN ISO 16000-7
Indoor air - Part 7: Sampling strategy for determi-
nation of airborne asbestos bre concentrations.

ENGLISH | 3
Safety rules
To safely operates the instrument, carefully follow
those indications.
1. Do not remove, for any reasons the enclosure
panels, without having turned o the instru-
ment and disconnected the power supply cable.
2. Always connect the instrument to a power
socket equipped with operational and ecient
grounding.
3. Do not operate the QB1 outdoor without hav-
ing provided protection from weather events
(rain, humidity etc).
4. Before starting any operation, nd a at and
stable accomodation for the QB1 with an ad-
equate sorrounding space for ventilation.
5. Operating temperature -10÷40°C
6. Max sampled gas temperature 45°C
7. Avoid contact and sampling of corrosive and
ammable compounds.
Precautions for humidity
Condense formation inside the sampler, reduces
the lifetime of some components, such as the pump
itself and dry gas meter as well.
Be sure the gases entering the QB1 are dry.
In case of presence of very wet/condensing gases
during the sampling, at the end of the operation,
allow the sampler to work with open air for at least
10 minutes.
The supply includes
QB1 is supplied with the following items:
♦QB1 sampler
♦Power cable
♦Sampling line quick connector
♦Hose barb for leak check
♦Operation quick guide

4| QB1 User Manual
6. Low ow regulation knob, range 0.2 ÷ 3.0 Nl/
min
7. High ow regulation knob, range 2 ÷ 32 Nl/min
8. Sampled gas exhaust, equipped with 1/8” gas
threaded connector
9. Protection fuse box, type 5x20 T1.6A
10. Power switch
2 Parts identication
Connections panel QB1 V1.5 -
V3.0
1. Vacuum meter indicating the line pressure drop
with range 0 ÷ 1 Bar
2. Ball owmeter, with indication scale in Nl/min
(@ 20°C e 101.3 kPa)
3. Water trap inspection window
4. Dust protection lter cap
5. Sampling line quick connector

ENGLISH | 5
Connections panel QB1 V5.0
1. Vacuum meter indicating the line pressure drop
with range 0 ÷ 1 Bar
2. Ball owmeter, with indication scale in Nl/min
(@ 20°C e 101.3 kPa)
3. Water trap inspection window
4. Sampling line quick connector
5. Flow regulation knob, range 2 ÷ 32 Nl/min
6. Flow regulation knob, range 2 ÷ 32 Nl/min
7. Sampled gas exhaust, equipped with 1/8” gas
threaded connector
8. Bypass valve (see chapter “6 Leak test - QB1
V5.0” on page 14)
9. Protection fuse box, type 5x20 T3.15A
10. Power switch
Inhaltsverzeichnis
Beliebte Laborausrüstung Handbücher anderer Marken

Agilent Technologies
Agilent Technologies 5800 ICP-OES Bedienungsanleitung

Endress+Hauser
Endress+Hauser Cleanfit CPA875 Bedienungsanleitung

NI
NI PXI-5422 Handbuch

Collomix
Collomix Aqix Bedienungsanleitung

SPEX SamplePrep
SPEX SamplePrep 6875 Freezer/Mill Series Bedienungsanleitung

Ocean Insight
Ocean Insight FLAME-NIR+ Bedienungsanleitung

Parker
Parker ALIGN-MG-NA Bedienungsanleitung

BD
BD 644787 Bedienungsanleitung

DENTAURUM
DENTAURUM Compact Megaplus Bedienungsanleitung

Biuged Laboratory Instruments
Biuged Laboratory Instruments BGD 626 Bedienungsanleitung

VWR
VWR SAS Super IAQ Bedienungsanleitung

illumina
illumina MiSeqDx Bedienungsanleitung