Desoutter CVI3 Vision Bedienungsanleitung

Part no 6159931430
Issue no 05
Date 11/2016
Page 1 / 72
www.desouttertools.com
Socket tray 6159360710
Socket tray User manual 4
Boîtier de sélection à douilles Manuel utilisateur 9
Selector de vaso Manual de usuario 14
Wechselbox für Steckschlüssel Bedienungsanleitung 19
Magazzino bussole Manuale dell’utente 24
Bandeja de soquete Manual do usuário 29
Hylslåda Användarhandbok 34
Aansluitkast voor steeksleutels Bedieningshandleiding 39
套筒选择器 操作手册 44
Półka gniazd Instrukcja obsługi 49
Selectorului de capete de chei Manual de utilizare 44
Zásobník na nástavce Návod k obsluze 59
Foglalat aljzat Felhasználói kézikönyv 52

Find more information and your Desoutter contacts on:
Software and documentation available at:
www.desouttertools.com
http://resource-center.desouttertools.com
No login/password required.

11/2016 3 / 72
6159931430
Issue no: 05
Series: -
SPARE PARTS LIST
Socket tray
High
Medium
Low
Item Description Part number Qty Service
level
1 Main board kit 6159183775 1 X
2PCB LED
report kit 6159188995 1 X
3PCB connector
kit 6159190235 1 X
4 Locking part kit 6155962005 1 X
5 Flat cable kit 6159166205 1 X
1
4
5
3
2

11/20164 / 72
6159931430
Issue no: 05
Series: -
Original instructions
© Copyright 2016, Ets Georges Renault
44818 St Herblain, FR
All rights reserved. Any unauthorized use
or copying of the contents or part thereof
is prohibited. This applies in particular to
trademarks, model denominations, part numbers
and drawings. Use only authorized parts. Any
damage or malfunction caused by the use of
unauthorised parts is not covered by Warranty or
Product Liability.
STATEMENT OF USE
This socket tray is designed for up to 4 different
sockets and is to be connected to the eBUS port
of the Desoutter CVI3 range of controllers.
No other use will be permitted.
For professional use only.
ON RECEIVING THE SOCKET TRAY
●Check the following items are included in the
packing box:
2
3
4
1
Legend
1 Termination plug SubD 9-pt P/N 6159176250
2 Socket tray
3 4 screws M5x20
4 4 washers
OPTIONAL ACCESSORIES
Description Part number
Tubes and pawns kit 6153980355
eBus cable 1 m 6159176210
eBus cable 3 m 6159176220
eBus cable 5 m 6159176230
eBus cable 15 m 6159176240
Bit module for screwdriver bits 6153980835
OVERALL DIMENSIONS IN MM
139
219
139.80
TABLE MOUNTING
●Secure the socket tray on the table by using
M6 screws.

11/2016 5 / 72
6159931430
Issue no: 05
Series: -
Dimensioning (bottom view)
3647
219
190
4 x Ø6.5
14.5
WALL MOUNTING
●Secure the socket tray on the wall by using 4
M6 screws.
Dimensioning (rear view)
33 30
190
4 x Ø6.5
14.5
EBUS CABLE ROUTING
It is possible to daisy-chain up to 15 accessories
e.g. socket trays, stacklights, I/O expanders on
the eBUS network.
●Before connecting, select how to pass the
cable:
on the side:
from below:
SOCKET TRAY CONNECTION
12
Legend
1 Termination plug SubD 9-pt
2 eBUS cable connection
Put the termination plug when:
-The socket tray is unique on the
eBUS network.
-The socket tray is the last accessory
on the eBUS network.

11/20166 / 72
6159931430
Issue no: 05
Series: -
CONTROLLER CONNECTION
●Connect the eBUS cable to the bottom panel
of the controller (see below).
24V-1A is supplied from the controller to
power the socket tray.
9
Legend
9 Controller eBUS port
Max current: 90 mA @ 24V DC.
SOCKET TRAY POSITION
1
Legend
1 Encoding wheel
●Remove the cap from the encoding wheel.
●By using a screwdriver, select the position
number of the socket tray on the eBUS cable:
(1-9 and A-F), 1 being the rst position, F the
last (F=15).
●Do not put the accessory in use when
the encoding wheel is set to "0".
●Put the cap back on the wheel.
SOCKET INSTALLATION
Internal centering of the socket
Pawn Ø ≤ socket M size Ø.
●Select the pawn and secure it by using the
screw mounted on the socket tray.
M10
M12
M14
M16
M18
0.35 Nm
External guiding of the socket
●Select the tube, slide the locking part to block
it and tighten with the knurled knob or the
screw+washer provided in the packing box.
T1
T2
T3
T4
T5
T6
2
1
Legend
1 Socket
2 Locking part
Socket outer Ø ≤ tube Ø.

11/2016 7 / 72
6159931430
Issue no: 05
Series: -
Tube no. Tube inner Ø (mm)
T1 15
T2 21
T3 24
T4 25
T5 27
T6 30
●If the socket is too short, cut the tubes.
●If the socket is too long, screw two or more
similar tubes together as shown below.
T1
T2
T3
T4
T5
T6
LABELING
Disassembly
●Loosen the 5 screws on the right side of the
socket tray as shown below.
●Remove the label and write the description
with a pencil.
Reassembly
Ensure that the seal is correctly
mounted.
●Add some glue and tighten the screws as
shown below.
1.5 N.m Loctite 243
SOCKET TRAY CONFIGURATION
You will need CVIPC/CVI CONFIG software to
congure the socket tray.
●Refer to chapter "I/O and accessories" in
CVIPC/CVI CONFIG user manual.

11/20168 / 72
6159931430
Issue no: 05
Series: -
BIT MODULE FOR SCREWDRIVER BITS
Range of bits
HEX 4 to 8
TORX 25 to 40
Mounting
17.7 mm
●Remove the V-shaped part.
●Place the module and secure it by using the
M5x20 screw supplied in the packing box.
Operation
2
1
Legend
1 Bit hole
2 Screw
●Insert the bit in the hole.
●Turn the screw clockwise for a heavier bit
and counter-clockwise for a lighter bit.

11/2016 9 / 72
6159931430
Issue no: 05
Series: -
Instructions originales
© Copyright 2016, Ets Georges Renault
44818 St Herblain, FR
Tous droits réservés. Tout usage illicite ou copie
totale ou partielle sont interdits. Ceci s’applique
plus particulièrement aux marques déposées,
dénominations de modèles, numéros de
pièces et schémas. Utiliser exclusivement les
pièces autorisées. Tout dommage ou mauvais
fonctionnement causé par l’utilisation d’une
pièce non autorisée ne sera pas couvert par la
garantie du produit et le fabricant ne sera pas
responsable.
DÉCLARATION D’UTILISATION
Ce boîtier de sélection à douilles a été conçu
pour utiliser jusqu'à 4 douilles différentes et doit
être connecté au port eBUS des coffrets de
vissage de la gamme CVI3 Desoutter.
Aucune autre utilisation n’est permise.
Réservé à un usage professionnel.
À RÉCEPTION DU BOÎTIER DE SÉLECTION À
DOUILLES
● Vériez que les éléments suivants sont
présents dans le colis.
2
3
4
1
Légende
1 Bouchon de terminaison SubD 9-pt
réf. 6159176250
2 Boîtier de sélection à douilles
3 4 vis M5x20
6 4 rondelles
ACCESSOIRES EN OPTION
Description Référence
Kit de tubes et pions 6153980355
Câble eBus 1 m 6159176210
Câble eBus 3 m 6159176220
Câble eBus 5 m 6159176230
Câble eBus 15 m 6159176240
Module embouts pour
visseuses
6153980835
ENCOMBREMENT EN MM
139
219
139.80
MONTAGE SUR TABLE
●Fixez le boîtier de sélection à douilles sur la
table en utilisant des vis M6.

11/201610 / 72
6159931430
Issue no: 05
Series: -
Dimensions (vue du dessous)
3647
219
190
4 x Ø6.5
14.5
MONTAGE AU MUR
●Fixez le boîtier de sélection à douilles au mur
en utilisant 4 vis M6.
Dimensions (vue de l'arrière)
33 30
190
4 x Ø6.5
14.5
PASSAGE DU CÂBLE eBUS
Il est possible de connecter en chaîne jusqu'à 15
accessoires sur le réseau eBUS, par exemple,
boîtiers de sélection à douilles, colonnes
lumineuses, modules d'extension d'E/S.
●Avant de connecter, choisissez comment
passer le câble.
Sur le côté :
Par en-dessous :
Andere Handbücher für CVI3 Vision
3
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Sprachen: