DeTech srl DTSPOT 31 10 2018 [Digitare qui]
ATTENTION: Before every trial, link the sensor to the receiver
1 Installing guide
Pick the best installation point for both the technologies and, if possible, position the unit towards the inside
of the area and far from doors, windows, moving objects and heat sources.
You get the best coverage by installing the detector at a 2.1 m heighmake sure the sensor has a clear view.
2.BATTERY INSERTION Remove the board and connect the battery to the circuit through the
connector, positioned on the back of the board and put it in the battery carrier on the D bottom.
Wait 2 minutes for the auto-calibration. The GREEN and RED LEDs will blink alternatively.
3. ACQUISITION The acquisition of the sensor in the system takes place when a Tamper alarm is
generated (by releasing the Tamper button) or setting the battery in “acquisition” mode.
4RADIO COVERAGE TEST When the battery is disconnected, push the Tamper button and
connect the battery. When the LED will blink, drop the Tamper button. The GREEN LED suggests a
good signaling, when the GREEN and RED LEDs blink, the wireless signal is not fit, with no blinking
the signal is absent. To end the Test, push the Tamper or wait for 4 minutes.
5. WALK TEST Once the lid is closed, the sensor will prepare for 3 minutes at the coverage test.
Move towards the space you need protection and verify the coverage through the microwave
green led and the infrared red led (the display is delayed 2 sec). The ending of the test will be
signaled by the green led. If the LED is off, increase the range by turning the trimmer clockwise.
Repeat the trial until you have obtained the requested status.
. N.BThe range a sto be set on the minimum required because the uW crosses the walls and a high range
won’t increase the performance of the system in the area.
When the RED LED blinks, it reports the infrared relevation
Premise: when functioning, at the detection of an alarm, the sensor is inhibited for 2 sec. If
the SET line of the De Unire is connected, the sensor won’t be inhibited, once the system is
inserted.
6. ALARM MEMORY
When the system is off, the sensor will display a possible alarm through the blinking of the green
and red led. The memory will be cancelled at the next insertion. It’s activated in LED OFF as well.
7. BATTERY SIGNALING The low battery status is signaled through the blinking of the RED LED. In
LED OFF also.
8.BATTERY REPLACEMENT To replace the battery, set the system in MAINTENANCE mode, open
the sensor, remove the battery, insert a new battery and close the lid.
9. WARNING:
•explosion danger if the battery isn’t replaced correctly. Replace it only with an equal or
equivalent type.
•In case the battery shows leakage of liquid, change it immediately. Afterwards, clean
your hands if you touched the fluid.
Warning: Because of its small dimensions, the product can be ingested easily. Keep away from
children
10. INFORMATION RELATING TO THE DISPOSAL (RAEE GUIDELINE)
•Warning: don’t throw this product in the normal trash bin!
•The electrical and electronical equipment must be managed separately in accordante with the
legislation requiasting the management, the disposal and recycling of such products
DISPOSAL OF THE BATTERY:
Warning: the battery contains polluting substances, therefore it must be put in special
predisposed to the collecting and disposal of polluting waste.
RED directive, rule EN 60950-1, EN 50130-4, EN 50130-5 EN61000-6-3, EN 300 440,
EN301489-3 e EN 62479
DECLARATION OF CONFORMITY EU
DeTech declares that the product is in accordance with the 2014/53/UE directive. The EU declaration of
conformity is available on the following site www.DeTechsrl.it
This product is ensured for 5 years (upon the occurrence of
malfunctioning or manufacturing faults).