©ASSA ABLOY Entrance Systems AB I Original instructions | 47.0446 / V1 - 04.21
ASSA ABLOY Entrance Systems AB hereby declares that the PAS024AMT is in conformity with the European directives
2014/53/EU (RED), 2006/42/EC (Machinery) and 2011/65/EU (ROHS).
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 13089612
Landskrona, February 2021 Matteo Fino, authorized representative and responsible for technical documentation.
The complete declaration of conformity is available on our website
This product should be disposed of separately from unsorted municipal waste
TECHNICAL SPECIFICATIONS
Supply voltage *:
Power consumption:
Mounting height:
Temperature range:
Degree of protection:
Noise:
Expected lifetime:
Presence
Typical response time: < 200 ms (max. 500 ms)
Active infrared with background analysis
Spot: 5 cm x 5 cm (typ)
Number of spots: max. 24 per curtain
Number of curtains: 2
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
Holdtime: 0.3 to 1 s
Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V)
Response time on test request: typical: < 5 ms
EN ISO 13849-1 PL «c» CAT. 2
(under the condition that the door control system
monitors the sensor at least once per door cycle)
EN 16005 (protective devices)
DIN 18650-1 (protective devices)
EN 12978
Motion
Min. detection speed: 5 cm/s
Microwave doppler radar
Transmitter frequency: 24.150 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm2
Solid-state-relay (potential and polarity free)
Max. contact current: 100 mA
Max. contact voltage: 42 V AC/DC
- in switching mode: NO/NC
- in frequency mode: pulsed signal in
no detection (f = 100 Hz +/- 10%)
- in inverted frequency mode: pulsed signal
in detection (f = 2.5 Hz)
Galvanically isolated current source
No detection: current source ON
Open circuit voltage: 6.5 V
Output voltage available at 10 mA: 3 V min.
Typical load: up to 3 optocouplers in series
Detection: current source OFF
Open-circuit remained voltage: < 500 mV
EN ISO 13849-1 PL «d» CAT. 2
EN 16005 (emergency exits)
DIN 18650-1 (emergency exits)
AutSchR
(only applicable for radar output in frequency mode
and current source output)
Detection mode:
Technology:
Output:
Test input:
Safety Standards:
Specifications are subject to changes without prior notice.
All values measured in specific conditions and with a temperature of 25°C.
12 V - 24 V AC +/-10% ; 12 V - 30 V DC +/-10%
< 2.5 W
2 m to 3.5 m
-25°C to +55°C; 0-95% relative humidity, non condensing
IP54
< 70 dB
20 years
PLEASE KEEP FOR FURTHER USE - DESIGNED FOR COLOUR PRINTING
* The Equipment must be powered by a SELV limited
power source ensuring double insulation between
primary voltages and the Equipment supply. The
supply current should be limited to max 3A.