RBS 2308Micro RBS
4 Environment
This section provides an overview of the operating environment, environmental
impact, and materials used in the RBS 2308.
4.1 Operating Environment
The operational temperature limits of the RBS 2308 depend upon the power
supply and whether or not the fan is used, see tables below.
Table 3 Start-up and operational requirements using AC power
RBS 2308 Variant Temperature range Relative Humidity
Without optional fan –33 Cto+45C15 –100%
With optional fan –33 Cto+55C15 –100%
Table 4 Start-up and operational requirements using DC power
RBS 2308 Variant Temperature range Relative Humidity
Start-up 0Cto+45C15 –100%
Operational, without
optional fan –15 Cto+45C15 –100%
Operational, with
optional fan –15 Cto+55C15 –100%
Temperature limits for transport, storage and handling of the RBS 2308 are
given in the table below.
Table 5 Transport, storage and handling climatic requirements
Condition Temperature range Relative Humidity
Transport –40 Cto+70C5–100%
Storage –25 Cto+55C10 –100%
Handling –40 Cto+70C5–100%
8 (30) EN/LZT 720 0327/3 Uen R1A