14
DIP Modes and functions Option Effect
DIP1 OFF
DIP2 Advance warning
ON the flashing light comes on and the operation begins after a 3
second warning
OFF the flashing light comes on and the operation begins
immediately
DIP3 Opening mode
ON step-by-step opening (the gate halts if a key command is
activated during opening, and closes if activated again)
OFF collective opening (the control board does not obey the key
commands during opening)
DIP4 Automatic or step-by-step mode
(for pedestrian and total operation)
ON automatic mode (the gate closes automatically after the
standby time has passed, which is adjusted using T.E.)
OFF step-by-step mode (the gate only closes when receiving the key
command)
DIP5 Automatic mode optional
(only if DIP4 = ON)
ON during standby, the gate obeys the key commands (this can be
closed before standby time finishes)
OFF
the gate cannot be closed until standby time finishes; a key
command (or photocell activation) will cause standby time to
restart
DIP6 Opening photocell testing ON testing enabled
OFF testing disabled
DIP7 Reserved for future upgrades ON always place in OFF
OFF always place in OFF
DIP8 Reserved for future upgrades ON always place in OFF
OFF always place in OFF
DIP9 Closing photocell testing ON testing enabled
OFF testing disabled
DIP10 Reserved for future upgrades ON always place in OFF
OFF always place in OFF
KM1800: function and mode selection using SW2 (DIP1 = OFF)
T.LG: garage light time
If the garage lighting circuit has been connected to the
control panel, regulate the time which the lights shall
remain on using T.LG.
•Minimum value: 3 seconds; maximum value: 90
seconds
T.E: gate open standby time
If automatic functioning mode has been programmed
(DIP4=ON), set T.E. to adjust standby time with the gate
open (before automatic closing begins).
•Minimum value: 0 seconds; maximum value: 90
seconds
P.M: motor torque
Adjust P.M at its maximum value, since the operator has a
mechanical clutch for torque adjustment.
KM1800: potentiometer adjustment