www.gemu-group.com10 / 20GEMÜ 1241
9 Manufacturer's information
9 Manufacturer's information
9.1 Delivery
●Check that all parts are present and check for any damage
immediately upon receipt.
The product's performance is tested at the factory. The scope
of delivery is apparent from the dispatch documents and the
design from the order number.
9.2 Packaging
The product is packaged in a cardboard box which can be re-
cycled as paper.
9.3 Transport
1. Only transport the product by suitable means. Do not drop.
Handle carefully.
2. After the installation dispose of transport packaging ma-
terial according to relevant local or national disposal regu-
lations / environmental protection laws.
9.4 Storage
1. Store the product free from dust and moisture in its ori-
ginal packaging.
2. Avoid UV rays and direct sunlight.
3. Do not exceed the maximum storage temperature (see
chapter "Technical data").
4. Do not store solvents, chemicals, acids, fuels or similar
fluids in the same room as GEMÜ products and their spare
parts.
10 Assembly and installation
NOTICE
●Pay attention to the information on product labels, in
product documentation and EC type examination certific-
ate.
●Connect cable carefully, do not damage individual wires.
●When connecting multiwire or finewire cables, prepare
the wire ends.
●Always use suitable pinch tools for pinching wire end fer-
rules in order to achieve consistent quality.
●Tighten all clamping points, even the ones not being
used.
1. Observe the national regulations and provisions.
2. Observe the installer provisions.
3. Protect M12 plugs against electrostatic build-up.
4. Protect M12 plugs against damage.
5. Lay cables securely and protect them from damage.
6. Differential voltage for two intrinsically safe electric cir-
cuits: maximum 30 V.
7. Connect open wire ends in a junction box with protection
class IP20 and higher or outside the EX area.
10.1 Preparations for assembly to the valve
1. Move the actuator A into zero position (actuator vented).
2. Remove optical position indicator 2 and / or protective cap
1 from the actuator top.
10.2 Threaded adapter assembly (linear actuator)
With some mounting kits, it is necessary to install a threaded
adapter as well. This threaded adapter is enclosed with the re-
quired mounting kits. Valves with a normally open and double
acting control function (code 2+3) also include additional O-
rings (1+2).
1. Move the actuator to the closed position.
2. Place O-rings 1 and 2 into threaded adapter 3.
3. Screw threaded adapter 3 into the actuator opening as far
as it will go and tighten.
10.3 Mounting kit assembly
Item Name Item Name
1 Spindle 7 Flange plate
2 Spring 8 Screws
3 Operating bush 9 Pressure disc*
4 Distance piece 10 O-ring*
5 O-ring 11 O-ring*
6 Adapter
* Included depending on version.
CAUTION
Pretensioned spring!
▶Damage to the device.
●Slowly release the tension in the spring.
CAUTION
Do not scratch the spindle!
▶A damaged spindle surface may cause failure of the
travel sensor.