Harman® • Accentra 52i Installation Manual_R16 • 2013 -___ • 09/1563-90-00574i
A
.
Design and Installation Considerations
1. Appliance Location
NOTICE: Check building codes prior to installation.
• InstallationMUSTcomplywithlocal,regional,stateand
nationalcodesandregulations.
• Consult insurance carrier, local building inspector, re
ofcialsorauthoritieshavingjurisdictionoverrestrictions,
installationinspectionandpermits.
Itisagoodideatoplanyourinstallationonpaper,usingexact
measurementsfor clearances andoor protection, before
actuallybeginningtheinstallation
Considerationmustbegivento:
• Safety,convenience,trafcow
• Placementofthechimneyandchimneyconnector.
• If you are not using an existing chimney, place the
appliance where there will be a clear passage for a
factory-builtlistedchimneythroughtheceilingandroof.
• Installing an optional outside air kit would affect the
locationoftheventtermination.
Suitable replaces for installation:
• MasonryFireplace
• ExistingFactoryBuiltWoodBurningFireplace
• Harman®ZeroClearanceCabinet-Part#1-00-574323
EXCEPTION:Masonryorsteel,includingthedamperplate,
mayberemovedfromthesmokeshelfandadjacentdamper
frameifnecessarytoaccommodateachimneyliner,
Marginal Location:
• Below peak
Location NOT recommended:
• Not the highest point of the roof
• Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended:
Outside Air Intake
on windward side
NOT recommended:
Outside Air Intake
on leeward side
Recommended Location:
• Above peak
Recommended:
• Insulated exterior chase
in cooler climates
Recommended Location:
• Above peak
• Inside heated space
Location NOT recommended:
• Too close to tree
• Below adjacent structure
• Lower roof line
• Avoid outside wall
Marginal Location:
• Wind loading possible
Figure 2.1
2 Getting Started
providedthattheirremovalwillnotweakenthestructureof
the replace and chimney, and will not reduce protection
forcombustiblematerialstolessthanthatrequiredbythe
NationalBuildingCode.
Sincepelletexhaustcancontainash,sootorsparks,you
mustconsiderthelocationof:
• Windows
• AirIntakes
• Air Conditioner
• Overhangs,softs,porchroofs,adjacentwalls
• Landscaping,vegetation
When locating vent and venting termination, vent above
rooflinewhenpossible.
Warning! Risk of Fire Damaged parts could impair safe
operation. Do NOT install damaged, incomplete or substitute
components.
NOTICE: Locating the appliance in a location of considerable
air movement can cause intermittent smoke spillage from
appliance. Do not locate appliance near:
• Frequently open doors
• Central heat outlets or returns
Installation and service of this
appliance should be performed by
qualiedpersonnel.Hearth&Home
Technologies recommends HHT
Factory Trained or NFI Certied
professionals.