Innovatione 1S PRO Bedienungsanleitung

1S PRO
Hair Removal Machine Instructions

Contents
Machine ........................................................................................................................................................4
Package.........................................................................................................................................................5
Technical Specications...................................................................................................................6
User manual ..............................................................................................................................................7
General information ...........................................................................................................................7
Precautions ................................................................................................................................................8
Contraindications ..............................................................................................................................11
Hair removal procedure recommendations .................................................................12
First use......................................................................................................................................................13
Turning on and o.............................................................................................................................14
Hair removal procedure................................................................................................................15
Machine cleaning and maintenance ..................................................................................16
Safety measures..................................................................................................................................17
Transportation and storage.......................................................................................................18
Resources, terms of service, and manufacturer’s warranty..............................19
Material information .......................................................................................................................20
Disposal .....................................................................................................................................................20
Certicate of acceptance and packaging........................................................................21
Preservation storage....................................................................................................................... 22
Revision record sheet .....................................................................................................................22

4
Machine
Applicator activation/
deactivation button
Applicator
Machine body
Power button

5
Package contents
Operator glassesMains tester
screwdriver
Valves to drain water
from the applicator
Customer glasses – 2 pcs Power cordFunnel

6
Technical specications
Professional Hair Removal Machine
Power consumption.............................................................................................................. 2000 W
Emitter resource...................................................................................................1,500,000 pulses
Safety sensors................................................................................................................................. 4 pcs
Package dimensions...................................................................................... 574/447/490 mm
Power supply...................................................................................................................................220 V
Cooling system.................................................................................................................Cooling Pro
System used ...............................................................................................................................IPLASER
Light wavelength............................................................................................700 нм – 1300 nm
Shipping weight........................................................................................................................22,5 kg
Developer............................................................................................................................Innovatione

7
User Manual
Attention! Prior to using the device, please read this User Manual carefully. If
you have any questions or experience any problems with the device, please
contact our Innovatione Customer Service Department by phone
+7 926 975 61 11.
If you have any questions or experience problems with the hair removal
procedure, please contact our Medical Department by phone
+7 926 547 03 33.
General information
Intended use: This product is intended to be used as a source of luminous
flux of a specific length to affect hair follicles.
Indications: The 1S PRO device is designed to remove hair and prevent their
subsequent growth. It is suitable for all 6 skin phototypes.
Buyers can order additional applicators, glasses, hoses with funnels, and
branded cleaning fluid from the manufacturer.

8
Precautions
1. Use this system strictly for its intended purpose as described in this
User Manual. Follow your doctor’s advice. Any other use of this device
is inappropriate and can be dangerous. The manufacturer is not liable
for any damage incurred due to device improper or unreasonable use
or if it was connected to the electricity mains incompatible with safety
requirements.
2. It is recommended to use the device with a quality 2,000 W mains
voltage stabilizer.
3. Prior to plugging the product into the mains outlet, make sure that the
mains voltage and frequency comply with the electrical specifications
shown on the specification plate on the back of the product.
4. The device must be used in a room temperature of 10 to 28o C.
5. If the device was exposed to conditions other than the acceptable
operating conditions, please wait until it restores its normal condition
before using it.
6. In case of the ingress of any extraneous liquids into the device, it must be
allowed to dry before use.
7. Do not use tap or purified water or other liquids not recommended by
the developer for the device system cooling.
8. Use the device in a clean environment free of dirt, dust, animal hair, etc.
9. The device should not be used near flammable substances or flammable
anesthetic mixtures with air, oxygen or premixed nitrous oxide.
10. It is forbidden to make any changes to the device design.
11. The device may heat up when used.
12. Do not place the device on top of any other equipment or under it. Do
not open the applicator body as it is not intended to be serviced.
13. Proper operation of this device may be impaired if you fail to follow these
User Manual instructions and/or do not use original spare parts.
14. Do not place the device on furniture and/or materials able to accumulate
static electricity.
15. While working with the device, the operator and the customer are
advised to avoid using things accumulating static electricity.
16. This device should be used intermittently in “1,000 pulses/10 min break”

9
mode. If used improperly, the device may be seriously damaged.
17. Do not place the device in water, as it is not water resistant.
18. Do not touch the device with wet hands.
19. Do not leave the device outdoors.
20. Place the device on a stable, horizontal surface at a distance of at least 4
cm from the walls.
21. Make sure that the air inlets in the device body are not clogged.
22. Do not allow disabled people or children to use the device.
23. Do not turn off the device by simply disconnecting its power cord from
the mains.
24. Do not use the device if it is damaged or its body has cracks.
25. It is recommended to have a spare applicator in case you cannot use the
applicator supplied (for example, when it was sent for replacement).
26. Do not use adapters (standard or with multiple connectors) or extension
cords.
27. Do not leave the idle device permanently connected to the mains.
Disconnect the device from the mains outlet if do not intend to use it for
a long time.
28. Follow the instructions when connecting the device parts. The
manufacturer is not liable for any damage caused by improper
connections.
29. Use the power cord supplied. The user is not allowed to replace
the power cord. In case the power cord is damaged, please contact
Innovatione Service Department by phone +7 926 975 61 11 to replace
the cord (the cord cannot be repaired).
30. Prior to any cleaning procedure or replacing the applicator, turn off the
device and disconnect it from the mains.
31. Clogged air inlets in the device body or applicator, dirty glass or improper
connections of the device parts may cause the device malfunction or
damage which is not a warranty case.
32. Do not expose the device to shocks and drops.
33. It is forbidden to open the device body, disassemble it, or repair it
yourself, or entrust the repairs to unqualified personnel without specific
authority for this activity type.
34. Do not apply excessive force to the device control buttons and its

10
structural elements when using it.
35. It is forbidden to expose the device to fire, moisture, or corrosive liquids
(alcohol, acids, alkalis, organic liquid substances, etc.).
36. Do not direct the applicator glass into the eyes. During the procedure,
make sure to use the protective glasses included in the package. It is
forbidden to use the device without protective glasses.
37. Keep this User Manual for future reference.

11
Contraindications
1. Epilepsy.
2. Pregnancy.
3. Lactation.
4. Hyperthermia.
5. Photodermatosis.
6. Oncology diseases.
7. Varicose veins.
8. Diseases, the progression of which may be affected by light waves.
9. Somatic diseases in the acute stage.
10. Weakened immune system.
11. Blood-clotting disorder or the use of drugs reducing blood clotting
(anticoagulants).
12. Acute infectious diseases.
13. Damaged skin on the application area.
14. The herpes virus in the acute stage.
15. Metal implants in the application area.
16. Neoplasms on the skin, malignant tumors.
17. Cochlear implants and/or pacemaker use.
18. Photosensitizing drugs use.
19. Diabetes mellitus in the decompensation stage.
20. Acute exacerbation of chronic diseases (systemic lupus erythematosus,
porphyria, eczema, psoriasis, lichen planus, ichthyosis, atopic dermatitis,
lupus erythematosus, scleroderma, bullous dermatosis, collagenosis,
vasculitis, and dyschromia).
21. Ischemic heart disease and hypertension.
22. In case of Botulinum toxin type A injections (Botox, Dysport, Xeomin,
Relatox), as well as various hyaluronic acid-based dermal fillers and
biorevitalizants injections, laser hair removal procedures can be carried
out in the injection areas no sooner than in 2 months after the injections
were administered.