inveo IND-U1 Bedienungsanleitung

User manual
RFID IND-U1 Reader
INVEO s.c.
ul. Rzemieślnicza 21
43-340 Kozy
tel: +48 785552252
www.inveo.com.pl
in o@inveo.com.pl

Dear Customer!
Thank you very much or choosing our product. Be ore its use, please read these
instructions care ully. There are given here the most appropriate ways o dealing with
this device, the basic principles o sa ety and maintenance. Please also keep the user
manual so that you can read it during later use.
Remember!
The manufacturer s not l able for any damage caused by mproper use of
the dev ce for ts ntended purpose or mproper handl ng, as well as fault dr ver
result ng from mproper use.
03/16/2018 User manual RFID-IND-U1 Page 2 z 16

Table of contents
1 PRELIMINARY INFORMATIONS..................................................................................................................4
2 PURPOSE OF THE DEVICE.............................................................................................................................5
3 WARRANTY AND LIABILITY OF THE MANUFACTURER......................................................................5
4 SAFETY GUIDELINES......................................................................................................................................6
4.1 POWER SUPPLY....................................................................................................................................................6
4.2 STORAGE, WORK CONDITIONS.................................................................................................................................6
4.3 INSTALLATION AND USE OF THE MODULE...................................................................................................................6
4.4 UTILISATION OF THE MODULE.................................................................................................................................6
5 CONSTRUCTION OF THE MODULE............................................................................................................7
5.1 GENERAL FEATURES..............................................................................................................................................7
6 DEVICE CONFIGURATION.............................................................................................................................8
6.1 OUTPUTS – OUTPUTS OPERATING MODE................................................................................................................
...............................................................................................................................................................................
6.2 INPUTS – STATUS OF INPUTS............................................................................................................................10
6.3 BUZZER & LEDS – LEDS AND SOUND SIGNALING CONTROL...............................................................................10
6.4 RS485 - CONFIGURATION RS485......................................................................................................................10
6.5 CARD SERIAL NUMBER - READ CARD NUMBER...........................................................................................10
7 MODBUS SUPPORT.........................................................................................................................................11
7.1 MODBUS ADDRESSES......................................................................................................................................11
8 DESCRIPTION OF TERMINALS...................................................................................................................14
DISTANCE FIXING HOLES...........................................................................................................................15
NOTES.................................................................................................................................................................16
Before start ng work w th the dev ce, read The User manual and follow the
nstruct ons conta ned there n!
03/16/2018 User manual RFID-IND-U1 Page 3 z 16

1 Prel m nary nformat ons
Before start ng work w th the dev ce, read The User manual and follow the
nstruct ons conta ned there n!
Description o visual symbols used in this user manual:
This symbol is responsible or reviewing the appropriate place in the
user instructions, warnings and important in ormation. Failure to
ollow warnings could cause injury or damage to the module
Important in ormation and guidelines
Following this guidelines makes the use o the module easier.
Attention: The appearance o the screen shots shown in this manual may di er slightly
rom the actual work with the module. The di erences may relate to the size and ont
type and size o symbols. There are no di erences in the content o the in ormation.
03/16/2018 User manual RFID-IND-U1 Page 4 z 16

2 Purpose of the dev ce
RFID-IND-U1 reader is used to read the UNIQUE transponders code. The transponder
code is available using the MODBUS RTU protocol.
3 Warranty and l ab l ty of the manufacturer
The manu acturer provides a 2-year warranty on the module. The manu acturer also
provides post-warranty service or 10 years rom the date o the introducing the module
on the market. The warranty covers all de ects in material and workmanship
The manufacturer undertakes to comply with the contract of guarantee, if the following
conditions are met::
all repairs, alterations, extensions and device calibrations are performed by the
manufacturer or authorized service,
supply network installation meets applicable standards in this regard,
the device is operated in accordance with the recommendations outlined in this
manual
the device is used as intended..
The manu acturer assumes no responsibility or consequences resulting rom improper
installation, improper use o the module, not ollowing this manual and the repairs o the
module by individuals without permission.
Th s dev ce doesn’t conta n serv ceable parts.
03/16/2018 User manual RFID-IND-U1 Page 5 z 16

4 Safety gu del nes
The module has been constructed using modern electronic components, according to the
latest trends in the global electronics. In particular, much emphasis was placed on
ensuring optimum sa ety and reliability o control. The device has a IP65 hermetic
housing with a high-quality plastic.
4.1 Power supply
The module is suitable or power supply 10-24VDC.
4.2 Storage, work conditions.
The reader is equipped with a sealed IP65 enclosure which means:
•total resistance to oreign objects
•resistance to water jet directed directly to the device
•storage and operation at temperatures rom -25 ° C to + 60 ° C,
4.3 Installation and use of the module
The module should be used follow ng the gu del nes shown n next part of the
user manual.
4.4 Utilisation of the module
When it becomes necessary to liquidate the device (e.g., a ter the time o use), please
contact the manu acturer or its representative, who are obliged to respond appropriately,
i.e., collecting the module rom the user. You can also ask the companies involved in
utilization and / or liquidation o electrical or computer equipment. Under no
circumstances should you place the device along with other garbage
03/16/2018 User manual RFID-IND-U1 Page 6 z 16

5 Construct on of the module
.1 General features
The reader is equipped with an RS485 port supporting MODBUS RTU protocol and
a USB port used or con iguration and testing o the module.
The device has two relay outputs and two inputs.
Techn cal data:
Supply voltage:12-24VDC
Power supply: 15mA (12V)
Transponders:
Supported transponder standard: UNIQUE
Carrier requency: 125kHz
Reading distance to 10cm (depending on the type o transponder used)
Communication:
1 RS485 port -modbus RTU
1 USB port to con iguration
Inputs/Outputs
2 relay outputs
2 inputs
Dimensions:
(width) 100 mm x (height) 100 mm x (depth) 55.6 mm
03/16/2018 User manual RFID-IND-U1 Page 7 z 16

6 Dev ce conf gurat on
A ter installing the RFID U1 Con ig program and starting it, connect the USB cable
to the computer and the module (in this case, the external power supply o the module is
not required - the device is plugged into the USB port).
The irst line o the program window displays in ormation about the version o the
con iguration program - PC vers on, reader so tware version - RFID Software and
reader version - RFID Hardware. We also have in ormation on whether the
con iguration program was connected to a reader - Connected - Not connected
F gure 1. Program w ndow v ew
03/16/2018 User manual RFID-IND-U1 Page 8 z 16

6.1 OUTPUTS – Outputs operating mode
Mode – Sets the output mode. The output can work in the ollowing modes:
DISABLE
BISTABLE
ASTABLE
TIME – the output will trip to the T me ON then the output will turn o (eg the
control o the electromagnet)
The work charts are shown in the igure below.
Power ON – the state o the output a ter turn on the power
•Act ve
•Inact ve
T me ON – the time or which the channel is switched on (Astable and Time mode)
T me OFF – the time interval between activations o the channel (Astable mode)
State – visualization o the output, i a rectangle is yellow it means that the output
current is turned on.
Buttons Out 1 and Out 2 outputs can be activate or deactivate.
03/16/2018 User manual RFID-IND-U1 Page 9 z 16
t
on
t
off
t
on
t
off
t
on
t
off
t
on
t
on
BISTABLE
ASTABLE
TIME

6.2 INPUTS – Status of inputs
Fields STATE INPUT 1 and STATE INPUT 2 dislays the actual state o inputs. Square
ield in black - input inactive, ield in yellow - active input.
6.3 BUZZER & LEDS – Leds and sound signaling control
In the BUZZER & LEDS settings we can indicate how the leds and the buzzer react when
the card is inserted into the reader.
•OFF - no reaction a ter card application
•ON READ -activation a ter card application
For example, select the option:
When the card is applied to the reader, the LED 1 will light up and the buzzer will sound,
LED 2 will be o .
These options help in interacting with the operator (the person applying the card knows
the reader correctly reads it).
Regardless of the selected sett ng, t s always poss ble to control the s gnal ng
v a the MODBUS RTU protocol.
6.4 RS48 - Configuration RS48
This ield is used to con igure the communication o the reader with the MASTER device.
MODE(setting o 9th bit o transmission):
None
Even – parity bit
Odd – odd bit
BaudRate – speed transmission boxi (1200, 2400, 4800, 9600, 19200, 38400,
57600, 115200)
Dev ce Address – device address or MODBUS protocol
6. CARD SERIAL NUMBER - Read card number
The ield displays the last RFID transponder code read and the type o card.
03/16/2018 User manual RFID-IND-U1 Page 10 z 16