IONIA U-BLUE Gebrauchsanweisung

Owner’s Operation Manual
Warning: Incorrect installation and/or operation could void your valuable warranty.
Please protect your investment! READ THIS MANUAL CAREFULLY
ALKALINE WATER IONIZER
Renement of Alkaline Ionized water(Hexagonal & Hydrogen Water)
U-BLUE

02
Safety Precautions
Hot
Water
If a break down occurs, do not make a repair by yourself. Contact the place of
purchase or A/S center.
If your ionizer becomes submerged
in water, unplug the power cord from
the wall BEFORE removing the
ionizer from the water.
Failure to do so may
cause electric shock!
NEVER attempt to repair or service the unit
yourself.
Contact your dealer.
Attempting to do so will void your valuable
warranty!
Do not use your ionizer at voltages other than
specified.
Do not plug in your ionizer where it will exceed
the rating of outlet or electric wiring.
Failure to do so can result in fire, injury and / or
damage to yourself, wiring or ionizer!
NEVER touch the power cord or plug with
wet hands.
- this may result in electric shock!
Protect your ionizer from freezing temperatures.
Protect your ionizer from direct sunlight.
Ensure the power plug is firmly and
properly inserted into the outlet.
- failure to do so may result in electric
shock or fire!
Do not attempt to repair or service the unit yourself. Contact your dealer.
Attempting to do so will void your valuable warranty!
Make sure to use your ionizer only with potable water which is suitable for
human consumption.
DO NOT use your ionizer with well water, water with extreme hardness,
high sediment or TDS levels without first consulting your dealer.
Do not run hot water through your ionizer.
Do not clean by pouring water over or spraying
the ionizer.
Unplug your ionizer if you plan not to use it for an
extended period or turn off the main power switch
on the back of the unit.
Filter replacement may be
necessary

03
Do not close, bend, pinch, press or otherwise
obstruct output ports or hoses.
If the appliance makes strange or unusual noises
or burning smells are detected, unplug the power
cord immediately and contact your dealer to
arrange service.
pH Reagent Liquid Precautions
pH Reagent Liquid Precautions
Some helpful tips
Some helpful tips
Do not expose the pH measuring reagent to extreme heat, flames or fire.
It is combustible.
For storing your alkaline water, glass or ceramic is best. Always try and
keep your stored water cool and away from direct sunlight.
You can use plastic, but only use lexan (number7) or poly bottles
(Nalge type). It is always best fresh out of the machine and ideal
if consumed on a day-today basis.
Do not store alkaline water in stainless steel, bronze or
aluminum containers.
Save the box and Styrofoam your ionizer came packed in.
This will help if your ionizer needs to be transported at a later date.
Do not use an ionizer downstream of a sodium-based ion exchange
softening system or Reverse Osmosis system without first consulting
with your dealer.
Do not drink the pH reagent liquid, put it in the eyes or apply to the body.
- If the liquid is ingested, induce vomiting immediately and call a doctor.
- If the liquid gets in the eyes, flush immediately and thoroughly with
cool water; call a doctor.
- If spilled or dropped on your body, wash if off immediately.
Make sure to keep the pH reagent liquid tightly closed and out of the
reach of children.

04
Name and functions of partsⅠ
Front
Body
Alkaline outlet cap

05
Back
Faucet cable
harness port
AC Power cord
Acdic water outlet
Tap water inlet
Fuse holder
Main switch
Rear cover
Filter cover

06
Name and functions of partsⅠ
Ⅰ
Acidic Water Outlet
Alkaline Water Outlet
Function display panel
Body
Faucet

07
Display
Power button
Start and stops water flow into your ionizer.
pH level indicator
This 4 of LEDs display will indicate which level(1~4) is selected.
Alkaline select button
Used to select alkaline water and the desired level(1~4).
Acidic select button
Used to select acidic water and the desired level(1~4).
Filtered Only select button
Used to select filtered water Ionization is not functioning in this mode.
Filter life indicator
Displays the current filter life used.
When the color change the Orange and flickers, it is time to replace your filter.
Filtered water button
Acidic water button
Power button
pH level indicator
Alkaline water button
Filter life indicator

08
Accessories (Needed for faucet installation)
Caution
Product Requirement :
Water pressure should be maintained at a constant rate, when the water pressure is
too low, water cannot flow through the unit.
Alkaline Water
Outlet Adapter
(Hole size: 5/16”)
Please connect to top cap of ionizer
for installation Faucet.
Color chart Manual
Manual
Dust Pre-filter
Connector cordDiverter
Gasket
(installed under
the Faucet)Circle Plate
Faucet
pH test kit
Large Alkaline
Water Fitting Small Acidic
Water Fitting
Hose(5/16")
(Alkaline
Water Hose)
Hose(1/4")
(Acidic Tap
Water Hose)
Alkaline Water
Outlet Adapter
Accessories

How to install the faucet
09
All the fittings are push in style fittings. To attach the hoses to any fitting, firmly insert the end of
the hose into the fitting. Pull firmly to check to connection - you should not be able to pull the
hose out. To release the hose from the fitting, you must push the spring loaded ring protruding
from the end of the fitting while pulling the hose out.
WARNING: Incorrect installation could void your valuable warranty.
Professional installation is recommended.
Use appropriate tools to make 1.14in.
diameter hole in the location where you will set
up the faucet. Make sure the faucet location will
allow both spouts to reach the sink.
After the faucet is fixed, connect it to fitting
with 5/16 in hose(for Alkaline) like figure4.
Check the hose whether it is inserted properly
or not. Also, connect it with 1/4” hose(for Acidic)
like figure4 and connect the faucet to the body
with connector cord.
Once, centered secure the faucet to the counter
by tightening the circle nut under counter until the
faucet is secure and sufficiently tight.
Center the faucet in the hole properly over
the gasket.
To connect the faucet
Figure1
Figure2
Figure3
Figure4
2
1
3
4

How to install
Place the Ionizer in an appropriate place under your sink.
Connect the 1/4inch Acidic Water Hose to the small fitting on the Acidic Hose extending
from the faucet to Acidic Water Outlet on the Ionizer. Pull firmly to check to connection
You should not be able to pull the hose out.
Connect 5/16 inch Alkaline Water Hose attached to the Fitting of the faucet to the
Alkaline Water Outlet on the ionizer. Pull firmly to check to connection - you should not
be able to pull the hose out.
Connect the diverter between the Tap water pipe.
Install the dust pre-filter in the middle of 1/4 inch hose with the arrow pointed at the ionizer.
Connect the 1/4 inch hose with dust pre-filter to Tap Water Inlet on the bottom of the ionizer.
Pull firmly to check to connection you should not be able to pull the hose out.
Join the wire from the faucet to the Connect Wire(Harness). Plug the Connector Cord into
the Connector Port on the top of the ionizer.
6
5
7
8
9
10
Tap Water
Diverter
Inhaltsverzeichnis