75.5317.00 20080111 Page 10 of 13
TROUBLE-
SHOOTING
BODYGUARD
DEPTH
PATTERNS
(Continued)
Row 1 (spots 1 through 6), are on during open door position and off during closed door position.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
HMSS will not set-up upon
initial powering
PROBLEM PROBABLE CAUSE CORRECTIVE ACTION
1. Check terminals 1 & 2 for proper voltage
24 V AC/DC + 10%.
2. Make certain that the field of detection is all
clear during the set-up and that all lenses
are installed on the sensor. If detection is
encountered upon initial set-up, the sensor
will continuously flash Green at + 2 Hz. The
sensor will also not set-up if permanent
stationary objects are extremely close to the
sensor. Ensure that, not only is the
detection field all clear, but that the sensor
is mounted properly (using the HMSS
Spacer if necessary).
3. Ensure that no high intensity lighting is in
the immediate area of the sensor.
1. Improper input voltage
2. Sensor is in detection
3. Potential interferences from high
intensity lighting
Door will not open once set-
up has been completed. 1. HMSS is in detection.
2. Improper wiring
3. Lockout safety beams are in
detection
4. Improper relay output configuration
1. Ensure that there is no detection occurring
at the sensor. If the Red LED is on steady,
there is detection. Make sure there have
been no changes in the field of detection
since set-up. If permanent changes have
occurred, launch a new set-up and re-test
door.
CAUTION: THERE POSSIBLY MAY BE NO
SAFETY ON THE DOOR WHEN
THIS TEST IS PERFORMED.
2. Remove the output wires (common,
normally open, normally closed) from the
Bodyguard. Activate the door control, if the
door opens, the fault exists with the sensor
or related wiring. If door does not open, the
faults may exist with the door control or it’s
related wiring.
3. Ensure proper relay output setting. Refer to
page 6. Typically, relay setting should be
‘Normally Open’. This means the relay
would close upon detection.
(4) Deep Without Row 1 (5) Middle Without Row 1 (6) Limited Without Row 1