LogTag USRID-16W Technisches Datenblatt

https://logtag.com
USRID-16W
Single-use USB PDF Electronic
Shipping Indicator
LogTag North America
Product User Guide
Document Release Version: 1.0
Published 7. April 2022
Copyright © 2004-2022, LogTag North America

USRID-16W User Guide 2
Contents
Introduction 6
Required Equipment 6
Features 6
Case 7
Buttons 7
Display 7
PDF 7
Software Requirements 8
Configuring the USRID-16W for logging 9
Standard Configuration Options 10
Configuring Multiple Alarms 11
Advanced Configuration Settings 13
File Settings 14
Finalizing the configuration 15
USRID-16W Start Options 16
Push button start 16
Date/Time start 16
Display Overview 17
Operating the Indicator 19
After the Indicator is configured 19
Starting the Indicator 20
During Recording 21
Stopping the USRID-16W 24
Plugging the USRID-16W into a USB port 27
Accessing the files 29
Interpreting the Data 30
Data Evaluation - Report 30
Data Evaluation - Data List 33

USRID-16W User Guide 4
Safety Information
The USRID-16W USB temperature indicator contains a non-
replaceable Lithium Battery. When the battery indicates “LOW”,
the indicator should be replaced, and the battery recycled or
disposed of according to your local regulations.
Do not expose the indicator to extreme temperatures as it may
lead to the destruction of the battery and may cause injuries.
Keep out of the reach of children.
Liability
LogTag North America’s standard warranty terms apply. A copy can be requested by
emailing [email protected]. In addition, LogTag North America shall not be
held liable
lif the device was used beyond LogTag North America’s stated limitations;
lfor any claims due to the improper storage and use of the device;
lfor any problems with refrigeration units;
lfor the bad quality of the monitored goods, if any;
lfor incorrect readings if the device was used with a low battery; or
lfor consequential loss.
Battery Life
The battery in the USRID-16W is designed to power the device for up to 3 months,
provided
lthe device was not stored for more than 24 months prior to activation;
lthe recording interval is not shorter than 5 minutes; and
lthe device is stored and operated according to LogTag North America’s
recommendations.
The USRID-16Wis unable to record readings when connected to USB. You cannot
use a USB power supply to power the device!
Disclaimer
The USRID-16W monitors temperature exposure and not the quality of the goods it
accompanies. Its purpose is to signal if product quality evaluation/testing is required.

USRID-16W User Guide 5
Typographical Conventions
Text in this font refers to buttons on the USRID-16W.
Text in this font refers to option settings, dialogue boxes or actions to be taken in
LogTag® Analyzer.
Text in this font describes features of the product.
This text describes certain aspects of the product, where incorrect use of a
feature may lead to inadvertent loss of data.
This text contains important information for the correct operation of
your USRID-16W.
This text contains information that explains some aspects of a feature in more
detail.
This text contains tips that help you get the best out of your USRID-16W
indicator

Introduction USRID-16W User Guide 6
Introduction
LogTag’s USRID-16W is a fully configurable, single-use USB PDF temperature indicator
with a built-in display, that can create temperature reports without the need to install
proprietary software or hardware at the destination. Minimum and maximum trip
temperatures as well as alarm trigger times can be reviewed directly on the display
without the need for a PC. The indicator can be configured using LogTag® Analyzer, and
is then placed with the goods to be monitored. At the destination the USRID-16W can be
plugged straight into a computer’s USB port and generates a PDF file, which can be
accessed using PDF software such as Acrobat Reader.
Required Equipment
Aside from the LogTag® USRID-16W Single-use USB PDF Electronic Shipping Indicator
you will need the following items:
la PC running Windows 7 SP1 or later and LogTag® Analyzer installed if you wish to
configure or download the indicator
la PC with PDF reader software installed for viewing the generated PDF files
Features
The USRID-16W Single-use USB PDF temperature indicator features the familiar LogTag
case layout with an additional USB plug at the bottom.

Features USRID-16W User Guide 7
Case
lMounting lug for secure fastening of indicator to fixtures
lUSB plug with protective cap - shields USB connector from moisture and dirt
lTemperature sensor located inside case
lDurable polycarbonate case, IP65
Buttons
lSTART/Mark button ( )
This is used to start the unit, place an inspection mark in the data, and clear active
alarms. It is also used to exit the statistics review.
lSTOP/Review button ( )
This is used to review recorded data at the end of the trip directly on the display
and to stop the unit.
Display
lShows the last recorded temperature and information about alerts
lAllows reviewing statistical data about the current trip
PDF
The USRID-16W will generate a detailed PDFreport when plugged into a USB port of a
PC. The PDF report shows a summary of the trip, presents the data in chart and list
format. A CSV file of the data list is also available.
The PDF can be shown in several different languages:
lEnglish
lFrench
lGerman
lRussian
lSpanish
The default ex-factory language is English. You can select which language to use during
configuration in the File Settings tab.
You can only change the language during configuration, but not when viewing
the PDF.

Features USRID-16W User Guide 8
Software Requirements
Software requirements vary depending on the type of file you want the USRID-16W to
generate when plugged into a USB port.
If you wish to configure USRID-16W products you will need to download the LogTag®
Analyzer software from the LogTag® web site at
https://logtagrecorders.com/software/lta3/download/. Follow the instructions to install
and start the software.
If you only plan to view a report, plug the USRID-16W into a computer’s USB port.
Depending on the settings made during configuration, a number of on-board files will
be generated1 and made available to you in a new drive:
la PDF file
you can open the file directly from the indicator‘s USB memory storage with
Acrobat Reader 4.0 or later, or any other compatible PDF reader software of your
choice2
la CSV file
this file can be imported into a spreadsheet program such as Microsoft Excel
lan LTD file
LTD files are LogTag® Analyzer's native, encrypted data files. You can open this file
in LogTag® Analyzer, where you can analyze data in detail, generate report files or
combine data from multiple recorders for comparison
You can also download data directly into LogTag® Analyzer without accessing the
indicator‘s on-board files.
1 Depending on the configuration, the USRID-16W may produce all, some or none of the files.
2 PDF files generated by any USB indicator can be opened directly in LogTag® Analyzer.

Configuring the USRID-16W
for logging USRID-16W User Guide 9
Configuring the USRID-16W for logging
Before a USRID-16W indicator can be deployed, it must be configured with the
parameters required for starting and recording temperature values.
Indicators can be purchased unconfigured, or pre-configured, ready to be started, using
one of a number of different profiles that are available.
You can check if your indicator is already configured or not by briefly pressing the
STOP/Review button.
The indicator is already configured to start
If your indicator is configured to start it will show either
if the indicator was pre-configured for a push-button start, or
if the indicator was pre-configured for a Date/Time start.
If your indicator shows one of these screens you may skip the configuration process,
although you can still re-configure the unit to change its recording parameters.
The indicator is unconfigured
An unconfigured USRID-16W indicator is delivered to you hibernated (i.e. in a state of
low power consumption), and pressing the STOP/Review button shows:
followed by and then
If your indicator is unconfigured you must set it up with the parameters required for
lstarting and recording temperature values;
lprinting the PDF; and

Configuring the USRID-16W
for logging USRID-16W User Guide 10
ltriggering alarms.
This is done using LogTag® Analyzer software, which can also be used for downloading
and analyzing data:
lStart the LogTag® Analyzer software.
lRemove the protective cap from the indicator's USB connector, plug it into a USB
socket on your computer and wait for the drivers to be installed3.
lFrom the menu click LogTag - Configure; LogTag® Analyzer will display the
configuration options for connected indicators.
Standard Configuration Options
The standard configuration options include settings such as User ID, start method, pre-
start recording, logging interval and duration, start delay, and password.
For detailed information about each parameter please read the section about
Configuring a LogTag® for logging in LogTag® Analyzer’s User Guide or press F1 for
help.
3 You can configure more than one USRID-16W at the same time, however it is practical to limit the number of units to about 6,
using a powered USB hub.
Andere Handbücher für USRID-16W
1
Inhaltsverzeichnis
Andere LogTag Messgerät Handbücher

LogTag
LogTag UTRED30-16 Technisches Datenblatt

LogTag
LogTag UTRED30-WiFi Bedienungsanleitung

LogTag
LogTag UTREL30-WIFI Bedienungsanleitung

LogTag
LogTag UTRED-16 Bedienungsanleitung

LogTag
LogTag WHO USRID-16W1 Technisches Datenblatt

LogTag
LogTag TIC20 Bedienungsanleitung

LogTag
LogTag TRID30 Bedienungsanleitung

LogTag
LogTag UTRED30-16 Bedienungsanleitung

LogTag
LogTag TRED30-7 Bedienungsanleitung

LogTag
LogTag TRED30-16R Bedienungsanleitung


















