Meaco MeacoWall 53B Bedienungsanleitung

Meaco Wall Mounted Dehumidifiers
MeacoWall 53B/W
MeacoWall 72B/W
MeacoWall 103B/W
Please read the manual before installation.
INSTRUCTION MANUAL [EN]
MeacoWall Series

2[EN]
SAFETY INFORMATION
ATTENTION
This dehumidifier must not be used in rooms under the following conditions:
Potentially explosive atmosphere
Aggressive atmospheres
Featuring a high concentration of solvents or chemicals
A high ratio of dust
Outside of the defined temperature ranges
Keep Children Away: Do not allow children to play with or around this unit, which could result in injury. Be
sure the unit is inaccessible to children when not attended.
Keep the Unit Grounded: The unit must be installed to a grounded supply in ALL applications by a qualified
electrician.
If the unit is to be installed in to a wet area (i.e. a swimming pool) please ensure that the mains connections meet
the criteria set out in section 602 of BS7671 other equivalent local regulation (non-UK)
Protect Power Cord from Damage: Never operate a unit with a damaged power cord, as this may lead to
electrical or fire hazards. If the power supply cord is damaged, it must be replaced by a cord of the same
type and amperage rating.
Extension Cords: This is not a suitable product to use with an extension lead, only use a fused spur.
Handle with Care: Do not drop, throw or crash the dehumidifier. Rough treatment can damage the
components or wiring and create a hazardous condition.
Mount on Level Surface: Ensure that the wall for mounting is level and true to avoid leakage and additional
vibration from the compressor. Always secure the dehumidifier to a wall.
Keep Out of Water: Never operate the unit in pooled or standing water, as this may create a risk of injury
from electrical shock. Do not store or operate outdoors. If electrical wiring or components become wet,
thoroughly dry them before using the unit. If in doubt do not use the dehumidifier and consult a qualified
electrician or a Meaco approved engineer.
Keep Air Intakes Clear: Do not clog or block the air intakes by placing the dehumidifier too close to anything
that will restrict the air inlet. This may cause the unit to overheat and result in a fire or electrical hazard.
Keep Filter Clean: Always use a clean air filter. Do not allow any material to clog the filter, as this may
cause the dehumidifier to overheat. Never use without a filter. Always check, and if necessary, clean the
filter before switching the dehumidifier on. Do not allow oil, grease, or other contaminants to be drawn into
the dehumidifier. Do not clean the dehumidifier with organic solvents.
Keep Electrical Components Dry: Never allow water inside the dehumidifier's electrical components. If
these areas become wet for any reason, thoroughly dry them before using the dehumidifier. If in doubt do
not use the dehumidifier and consult a qualified electrician or a Meaco approved engineer.
The operator must: Make the operating instruction available for the user and make sure that the user does
understand the manual.

3[EN]
Electrical Installation
The unit must be installed to a grounded supply in ALL applications
If the unit is to be installed in to a wet area (i.e. a swimming pool) please ensure that the mains connections
meet the criteria set out in section 602 of BS7671 other equivalent local regulation (non-UK)
This unit is supplied without a plug and is expected to be connected to s fused spur
by a qualified electrician following local regulations and laws. Please make
reference to the unit’s start-up voltage before connecting to a power supply.
All units are supplied with a 3 metre 16 amp cable.
53L
72L
103L
Rated Voltage
220 - 240V / 50Hz
Power Consumption (kW)
0.93
1.13
1.97
Running current (amps)
4.1
5.0
8.7
Start-up current (amps)
4.3
5.85
10

4 [EN]
1. FIRST THING TO DO
Before putting your dehumidifier into operation for the first time, the instruction manual should be studied carefully.
After receiving the unit, you should check your dehumidifier for any transport damage. In case of damage, you
should inform the sender immediately.
Keep the packaging for the dehumidifier in a safe place in order to be able to despatch the dehumidifier safely if it
requires a service. In order to save space, you can simply cut through the adhesive tape using a knife and fold up
the cardboard box.
2. DEHUMIDIFIER PRINCIPLES
This dehumidifier is designed to reduce humidity from the air in a building or part of a building. The purpose is to
help dry laundry, prevent condensation, mould, musty air and other issues associated with high relative humidity.
The time necessary for the dehumidifier to dry a room and reach the desired relative humidity depends on the
environmental conditions prevailing within the room. For example the number of air changes with outside, any
sources of moisture and the room temperature can all either speed up or slow down the dehumidification process.
The dehumidifier functions according to the condensation principle with heat recovery. The fan takes the humid air
from the room in and across a filter and then through an evaporator. Here the air is cooled below dew point so that
the water vapour of the air forms a condensate on the coils which flows into the internal container ready to be
poured away. The cooled and dried air is heated again by a condenser. By recycling the room air through the
dehumidifier over and over again the moisture content and relative humidity of the air is reduced.
Always try to avoid installation in direct sunlight as this will affect the accuracy of the relative humidity reading that
the dehumidifier will be using for control.

5[EN]
3. WHAT IS IN THE BOX
4. INSTALLATION AND TRANSPORTATION
For installation and transportation, the following instructions must be considered:
The air inlet and the air outlet must not be covered whilst the dehumidifier is in operation.
Before moving the dehumidifier it must be switched off by its ON-OFF switch. The dehumidifier must be
disconnected at its fused spur and excess water should be drained.
For transportation the dehumidifier should be secured on a level base only and must be prevented from
rolling around.
The dehumidifier must always be transported vertically.
The dehumidifier must always be secured to the wall. Make sure that the wall that it is being fixed
to is strong enough to support the weight.
This dehumidifier must be used exclusively for drying the air.
If the dehumidifier has been in a horizontal position for any time over a few minutes, you must let it stand in
the upright position for at least 24 hours before operating. This allows the oil to drain back into the
compressor.
When installing in a wet area like a swimming pool room always make sure that you are complying with
local electrical and safety regulations.
Minimum Installation Distances

6 [EN]
Using the enclosed drills five holes for the wall mounting bracket and secure using the expansion bolts. The
wall must be true and the bracket level or water will leak from the dehumidifier.
5. CONTINUOUS DRAINAGE
This dehumidifier is designed to be connected to a permanent drain via a 16mm hose. Make sure that the drain
connection is running downhill and does not have any kinks or blockages.
As standard the hose is fitted ready to come out of the right of the dehumidifier as you look at it from behind.

7[EN]
If you wish to move the drain to the other side then you can do so by removing the side covers.
This should only be done by a qualified electrician and only when the
unit’s power supply has been turned off and isolated.
Remove the one screw as per above to access the side panels.

8 [EN]
Connect the condensate hose (16mm diameter) and ensure that the water is flowing downhill with no kinks or blockages.
You have the choice of fitting the drain on the right or left side. The hose on the right is pre-fitted, if you wish to change to
left then remove the bung from the left and swap it with the hose on the right.

9[EN]
Please keep the dehumidifier upright at all times prior to installation. If the dehumidifier is inclined greater than 60 degrees
then the dehumidifier should only be turned on 24 hours after it has been installed.
60°

10 [EN]
6. CONTROL PANEL AND USING THE DEHUMIDIFIER
When you turn the dehumidifier on the display will show 88 and then the program version number for
ten seconds. This is to allow the relative humidity sensor to sample the air and to take a reading.
The display will dim after 90 seconds of no keys being pressed.
Turning the dehumidifier On or Off
Press the On/Off button to turn the dehumidifier on or off.
Andere Handbücher für MeacoWall 53B