Milltronics IQ Radar 160 Bedienungsanleitung

33455500
Rev1.0

hank you for purchasing Milltronics products. We endeavour to design
equipment that is simple to use and reliable in its operation, with the aim
of satisfying our customers' needs.
Milltronics has been designing and manufacturing process equipment since
1954. Our fields of expertise include ultrasonic and capacitance level
measurement, in-line weighing of dry bulk solids and motion sensing.
Milltronics is established world wide through associate offices and
representatives. Our network is continually being refined to provide our
customers with first rate sales information, engineering assistance and after
sales support.
For more details on our products and service, please contact us and we will
provide you with a listing of the offices or representatives nearest you.
T

_
PL-550 3
TABLE OF CONTENTS
GENERAL INFORMATION
About This Manual.................................................................................................5
About IQ Radar 160...............................................................................................6
SPECIFICATIONS
IQ Radar 160...........................................................................................................7
INSTALLATION
Location....................................................................................................................9
Dimensions............................................................................................................10
Mounting................................................................................................................11
Flanged.........................................................................................................11
Extension Requirements...........................................................................12
Rod Assembly .............................................................................................13
Interconnection ..................................................................................................14
Terminal Block Layout...............................................................................14
Wiring.............................................................................................................15
START UP
Overview ................................................................................................................17
Display and Keypad............................................................................................19
Local Operation....................................................................................................20
Run Display..................................................................................................20
Run Keypad.................................................................................................21
Program Display..........................................................................................22
Program Keypad.........................................................................................23
Local Programming....................................................................................24
OPERATION
Overview ................................................................................................................27
Transceiver............................................................................................................28
Blanking.................................................................................................................29
Loss of Echo.........................................................................................................30
Analog Output......................................................................................................31
Programming...............................................................................................31
Run.................................................................................................................31
Fail-safe.........................................................................................................32
Run / Program......................................................................................................32
Application Example...........................................................................................33
PARAMETER DESCRIPTION ...........................................................................................35
TROUBLESHOOTING ........................................................................................................41
MAINTENANCE ...................................................................................................................43
APPENDICES
Alphabetical Parameter List..............................................................................45
Programming Chart ...........................................................................................46

PL-550 4

_
PL-550 5
GENERALLINFO. _
GENERAL INFORMATION
ABOUT THIS MANUAL
It is essential that this manual be referred to for proper installation and operation
of your IQ Radar 160.
Installation
gives you step-by-step direction for the installation and
interconnection of your IQ Radar 160.
Start-up
instructs you in how to operate the keypad, program the unit
and read the display.
Operation
describes the operation of the IQ Radar 160, detailing the
interoperation of the salient features.
Applications
looks at the IQ Radar 160 from a practical point of view, using
a typical application example.
Parameters
lists the parameters available to you, with a description of their
function and use. You are urged to read this section to
familiarize yourself with the parameters available to you and
get your IQ Radar 160 working to its fullest.
Troubleshooting
tabulates symptoms, causes and actions to common
installation and application problems that you might encounter.
Hopefully you will never have to read this section, but know it’s
there to help you.
Appendices
what manual would be complete without one! Ours is an
alphabetical cross-reference of the parameters and their
numbers, and a record sheet for jotting down parameter
values. Handy indeed!

PL-550 6
GENERAL INFO.
ABOUT IQ RADAR 160
The IQ Radar 160 is to be used only in the manner outlined in this manual.
IQ Radar 160 is a versatile process material level monitoring instrument. Material
level measurement is achieved using advanced pulse radar techniques. The unit
consists of an electronic component coupled to the antenna.
IQ Radar 160 Features:
✓ANSI, DIN flange or sanitary tri-clamp mounting
✓corrosion-resistant construction, aluminum enclosure with stainless steel and
Teflon®wetted parts
✓local display
✓infrared keypad and Dolphin-compatible
IQ Radar 160 Applications:
✓liquids, slurries
✓process temperatures up to 200°C
✓vacuum and pressurized vessels
IQ Radar 160 Approvals and Certificates
✓safety and radio
® Teflon is a registered trademark of Du Pont.

_
PL-550 7
SPECIFICATIONS _
SPECIFICATIONS
IQ RADAR 160
Power: 100/115/200/230 ±15% V ac*, 50/60 Hz, 15 VA
*factory set – see device nameplate
Interface:
analog output: optically-isolated 0/4-20 mA into 750 Ωmax,
0.02 mA resolution
Dolphin/RS-485 link: refer to Dolphin product specification
programmer link: infrared receiver (refer to Programmer
specification below)
display (local): backlight, alphanumeric and multi-graphic liquid
crystal for readout and entry
Performance:
frequency: 5.8 GHz
accuracy: > ±0.3% of range (1 to 10 m)
range: 10 m
repeatability: 30 µW average
fail-safe: mA programmable high, low or hold
Mechanical:
enclosure (electronic):
construction: aluminum, epoxy coated
conduit: 2 x 1/2" NPT or PG 16 entry
ingress protection: Type 6 / NEMA 6 / IP-67
resonator: plated aluminum
flange: 316 stainless steel, 150 psi ANSI, DIN PN16,
3" sanitary tri-clamp
antenna:
type: dielectric rod
construction: Teflon®
weight: 6.5 kg (14.3 lb) with 2"/150 psi ANSI flange,
weight will vary with flange size and rating

PL-550 8
SPECIFICATIONS _
Environmental:
location: indoor/outdoor
altitude: 2000 m max
ambient temperature: -20 to 60°C (-4 to 140°F)
relative humidity: suitable for outdoor
(Type 6/NEMA 6/IP 67 enclosure)
installation category: II
pollution degree: 4
Process:
material dielectric: εr> 4
temperature: -40 to 200°C (-40 to 392°F)
pressure (vessel): -100 kPa to 1000 kPa
(-1 to 10 bar or -10 to 150 psi)
Programmer (remote keypad):
enclosure: general purpose
67 mm w x 100 mm h x 25 mm d
(2.6" w x 4" h x 1" d)
ambient temperature: -20 to 50°C (-5 to 122°F)
interface: proprietary infrared pulse signal
power: 9V battery (ANSI/NEDA 1604, PP3 or equivalent
weight: 150 g (0.3 lb)
Approvals (refer to device nameplate) :
safety: CSANRTL/C, CE
radio: BAPT, Transport Canada

_
PL-550 9
INSTALLATION _
INSTALLATION
LOCATION
Installation shall only be performed by qualified personnel
and in accordance with local governing regulations.
This product is susceptible to electrostatic shock.
Follow proper grounding procedures.
Do not mount in direct sunlight without the use of a sun shield.

PL-550 10
INSTALLATION _
DIMENSIONS
* Flange thickness varies with size and rating. 25mm (1") nominal.
Check appropriate standard.
◊Standard length, 50 and 100 mm (2” and 4") extensions available.
enclosure/
electronics
antenna
(rod)
antenna
(resonator)
flange or
tri-clamp
136 mm
(
5.4"
)
75 mm
(3
.
0
"
)
50mm
(
2.
0
"
)
211 mm
(8
.
3
"
)
41 mm
(
1.6"
)
183 mm
(
7.2"
)
412 mm ◊
(16.3")
245 mm
(
9.6"
)
Inhaltsverzeichnis
Andere Milltronics Messgerät Handbücher

Milltronics
Milltronics HydroRanger I Bedienungsanleitung

Milltronics
Milltronics airanger XPL plus Bedienungsanleitung

Milltronics
Milltronics miniranger plus Bedienungsanleitung

Milltronics
Milltronics COMPUFLO III Bedienungsanleitung

Milltronics
Milltronics Mercap MCP01 S series Bedienungsanleitung

Milltronics
Milltronics MultiRanger Plus PL-513 Bedienungsanleitung

Milltronics
Milltronics AIRANGER DPL PLUS Bedienungsanleitung

Milltronics
Milltronics MultiRanger Plus Bedienungsanleitung

Milltronics
Milltronics HydroRanger Plus Bedienungsanleitung

Milltronics
Milltronics ILE-37 Bedienungsanleitung