Pertech 6100 Series Bedienungsanleitung

6100 Series Scanner
USERS GUIDE
www.pertechindustries.com 220350A -REV 00

Pertech 220350A I

Pertech 220350A II
Federal Communications Commission (FCC) Radio
Frequency Interference Statement
Warning
Changes or modications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and , if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communica-
tions. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at
his own expense.
Information to the User
This equipment must be installed and used in strict accordance with the manufacturer’s instructions. However, there is no guarantee that interference of radio
communications will not occur in a particular commercial installation. If this equipment does cause interference, which can be determined by turning the equip-
ment off and on , the user is encouraged to contact Pertech immediately.
Pertech is not responsible for any radio or television interference caused by unauthorized modication of this equipment, or the substitution of attachment or con-
nection cables and equipment other than those specied by Pertech. The correction of interferences caused by such unauthorized modication, substitution or
attachment will be the responsibility of the user.
Important Information to the User
In order to ensure compliance with the Product Safety, FCC and additional agency markings requirements, you must use the power supply, power cord, and inter-
face cable which were shipped with this product.
Power Supply
(LPS) output for use in North America, input rated 100 - 240 Vac, .4 A, 50/60 Hz, Output rated 24Vdc, .625 A Maximum and 15W Maximum. Use of this product with
a power supply other than the approved Pertech power supply supplied will require you to test this power supply and the Pertech scanner for FCC and additional
agency mark certications. For more information check with your Pertech representative for current agency requirements.
Interface Cable
A shielded (360 degree) USB certied interface cable must be used with this product. The shield must be connected to the frame or earth ground reference at each
end of the cable.
Use of a cable other than the described here will require that you test this cable with the Pertech scanner and your system for FCC and USB mark certication.
Power cord
For North America a NRTL Recognized detachable power cord must be used. For applications where the power supply module may be located on the oor, a
power cord with Type SJT marking must be used.
For applications outside of North America, Power cords which meet the country of installation’s certication and application requirements must be used.
Use of a power cord other than described here may result in a violation of safety certications which are in force in the country of use.
Disclaimer
Information in this document is subject to change without notice. Consult your Pertech sales representative for information that is applicable and current. Pertech
reserves the right to improve products as new technology, components, software and rmware become available.
No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose with out the express written
permission of Pertech.
Industry Canada
This Class A digital apparatus complies with Industry Canada Standard ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 d’Industrie Canada.
Copyright
Copyright © 2007-2015 by Pertech.
Riverton, Wyoming USA
All rights reserved. Printed in USA. Condential,
Unpublished. Property of Pertech® Inc...
Trademarks
Pertech® is a trademark of Pertech. Other trademarks
and registered trademarks are the property of their respective holders.
Web site
http://www.pertechindustries.com/

Pertech 220350A III
Contents
Where to Get Additional information...........................................................1
Preface .......................................................................................................1
Models & Options .......................................................................................1
Unpacking the Scanner ..............................................................................2
Choosing a Location...................................................................................2
About the 6100 Scanner ............................................................................3
Features Identication ...............................................................................3
Cables and Connections ............................................................................4
Connecting the Cables ...............................................................................4
USB 2.0 Interface .......................................................................................4
Printer View ................................................................................................4
Power Supply .............................................................................................5
Hardware and Software Requirements ......................................................5
Installing the Driver.....................................................................................5
Power Supply Connector............................................................................5
Operating the Scanner ...............................................................................6
Typical Form Handling ...............................................................................6
Typical Form Scanning Process .................................................................6
LED Indicators ............................................................................................7
ID Card Scanning Process .........................................................................7
Stamp Installation & Replacement .............................................................8
Preventive Maintenance .............................................................................9
Clearing Jams.............................................................................................9
Feed Issues ................................................................................................9
6100 Scanner Specications ....................................................................10
Dimensions...............................................................................................10
Service & Support..................................................................................... 11
Warranty Information ................................................................................ 11

220350A 1
Preface
This manual has been written to help you Install and Operate your Pertech® 6100 Series Scanner. Feel
free to contact us if you need further assistance after reading this manual. Please see the Troubleshooting
Scanner Problems section of this manual and determine the complete part number of your scanner prior to
calling. Pertech provides technical support Monday through Friday from 8:00 AM to 5:00 PM MST at 307-
856-4821.
Every effort has been made to insure the information in this manual is complete and accurate. Feel free to
contact us with any comments concerning this manual. Pertech assumes no responsibility for errors.
Where to Get Additional information
The following publications contain more information about the 6100 series scanner. Contact your Pertech
sales representative to obtain additional copies of this Manual or any of the publications listed below.
Title Part Number
6100 Scanner: Setup Guide 220349
6100 Scanner: Users Guide 220350
6100 Scanner: Service Guide 220351
6100 Scanner: Pertech API Programming Manual 220346
6100 Scanner: Command Manual 220347
6100 Parts Information Manual
Ordering Supplies
The following section lists the paper and supplies available for order. In addition to paper and ribbons,
Parts, service and repair may be obtained by calling 1-800-800-6614.
Description Part Number
Sun Stamp 108762-001
Imaged Stamp 108762-002
6100 Scanner Certied USB Cable 6’ 106356-011
6100 Scanner Certied USB Cable 10’’ 106356-014
6100 Scanner Contact Image Sensor Wipe 108784
Unique Item Examples
Orientation Vertical or Horizontal
Stand
Adjustable Deck Guide
Deck Options
Case Color
Firmware
Logos
Cables
Available Models:
613211-001
}
}
}
}
}
}
}
Unique Feature Identier
Software Compatibility Identier
5=Ranger Silver Bullet, 0= None
Model Series 61=6100 Family
Contact Image Sensor - Color - 2=2 Color, 3= B/W
DPI Capability - 2=200, 4=400
MICR - 0=No, 1= Yes
Stamp - 1= Yes, 2=No
Models & Options
www.pertechindustries.com
Pertech

Pertech 220350A 2
Unpacking the Scanner
Save all packing materials in case you need to repack the scanner.
To report a scanner that was damaged during shipping, see “Contact Information” on the last page of this
Guide.
To repack the scanner, consult the below illustration and use the original packing materials.
Choosing a Location
Place the scanner on a level surface on or near the host computer. Leave space to open the cover, and to
insert a form.
The maximum distance from the scanner to the host and the power supply is: 6 feet (USB interface). The
scanner should be placed in a location that minimizes Electro-Magnetic Interference (EMI), a minimum of 1
foot away from monitors.

Pertech 220350A 3
About the 6100 Scanner
The 6100 scanner is a manual single sheet feed imaging solution that has duplex imaging, (both front and
back of form). The scanner is capable of rear exit single pass stacking of at least 10 checks, and images
standard 256 bit gray scale @ 200DPI imaging. Image compression is CCITT G4 (black/white) or JPEG
(grayscale). The 6100 Series Scanner also has an optional MICR reader and form defacing stamp. USB
2.0 interface comes as the standard interface.
The MICR reader is in-line with the image scanner with on-board rmware decoding of E13B MICR char-
acters. Comes Standard with 32MB of DRAM memory upgradeable to a maximum of 64MB and super fast
document processing speed of 10 inches per second.
9. Mechanism Feed Sensor
2. Contact Image Sensor
4. Entrance to Rear
Exit Tray
3. MICR Read Head
8. Form-in Sensor
6. Defacing Stamp
7. ID Card Sensors
10. LED Indicator
5. Stamp Release
Actuator
1. Pressure Rollers
11. Entrance Tray
12. ID Card Diverter
1. Rear Deck
2. ID Card Exit Path
3. USB Interface
4. Power Connector
5. Power Switch
1
2
5
4
3
1
1
7
2
2
3
4
5
6
8
9
10
11
12
13. Mid-Field Sensor
13
Features Identication

Pertech 220350A 4
Connecting the Cables
Caution: Be sure the power switch is turned off before
connecting cables.
1. Make sure the unit is on a level surface.
2. Make sure the Scanner is powered off.
3. Connect the Power Supply to the Scanner.
3. Connect the Power Supply to the Power Source.
4. Connect The USB cable to the back or the scanner.
5. Load drivers on the PC (See Page 5 of this manual).
6. Connect the USB Cable to the PC and turn the scanner on.
USB Interface
Power Connection
Power Switch
Cables and Connections
USB 2.0 Interface
Standard Pinout
Pin 1 EOT/VCC
Pin 2 D-
Pin 3 D+
Pin 4 GND
Pin 5 GND
Pin 6 GND
The USB cable may be attached or detached when the
system is on. When Using the USB interface the Win-
dows® Operating System will automatically install the
USB port driver. Pertech has available scanner drivers
at www.pertechindustries.com.
Warning: When Hot Swapping USB cable
make sure that cable is installed into the
correct connectors or damage to the scanner
could result.
USB Cable Part
Number 106356011
Printer View

Pertech 220350A 5
Power Supply
To avoid damage to the scanner connect the Power Supply last.
1. Make sure the scanner power switch is off.
2. Plug the Power Supply Cable into the scanner. The power supply cable con-
nector has a locking mechanism to ensure that the cable stays fastened to the
scanner. When removing the cable release the locking mechanism by pulling the
mechanism away from the scanner.
3. Plug the Power Supply Cable into a grounded outlet.
4. Reference “Connecting the Cables” on the previous page to complete the pro-
cess.
Connector Cable
Locking Mecha-
nism
Installing the Driver
Windows XP, 2000, Vista Drivers
1.Download the 6100 USB driver from the Pertech Website. Unzip the le to a directory of your choosing . Make a
note of this location. (Silver Bullet users can skip this step and install the Silver Bullet software.)
2.Next, plug in the 6100 into the host computer’s USB 2.0 bus and power up the unit.
When the 6100 Check Scanner is plugged into a USB port for the rst time, Windows XP
will automatically start the “New Hardware Wizard”. Follow the instructions of the hardware
wizard, Browse to the directory where the unzipped 6100 driver les are located. (Silver Bullet users will auto-
matically nd the driver les.
3.Windows will give a message that the driver is not signed, click “Continue Anyway” to install the driver.
Note that this also installs a WIA class device for the 6100, but the check scanner cannot be used in this manner.
Running the scanner requires writing an application that accesses it
through the supplied PertechAPI.
Note, driver installation for Silver Bullet models is done as part of the Silver Bullet Software installation. See Silver
Bullet documentation for additional instructions regarding Silver Bullet software.
Hardware and Software Requirements
USB 2.0
Windows XP, 2000, Vista, or 7 Operating System. Pentium 4, 256MB RAM or higher recomended.
Windows drivers / SDK /Application Program Interface are available off the Pertech web site. The 6100 Scanner
can be purchased with Silver Bullet Technology plug and play capability.
www.pertechindustries.com
Pertech can supply an API for developers who wish to interface the scanner directly into their application
software. Contact your Pertech Representative for the necessary les and documentation.
Printer
Connectiion
Power Supply Connector

Pertech 220350A 6
Operating the Scanner
Typical Form Handling
The 6100 teller scanner handles forms between 2 and 3.67
inches wide and 3.2 to 8.75 inches in length. The scanner will handle thicknesses between #16 to #32
(3.0 to 7.5 mills; .032" for ID Cards), with rear exit single pass stacking of a of 10 checks. The unit has a
in-line MICR reader with on board software for decoding E13B MICR characters
To load a form into the scanner insert the form justied to the right, face down with the
MICR line to the right side of the scanner.
MICR Line
Check face down with
MICR Line to Right side
Typical Form Scanning Process
The application software calls for the user to insert a form
into the scanner. The Green Power On LED begins blinking
to indicate that the scanner is waiting for a form.
There are two sensors (#8,#9) identied in the Features Iden-
tication on page 3. The rst sensor tells the scanner that a
form is present, activates feed the motor and draws the form
into the scanner.
The second sensor, if activated, passes the form through to
the imaging heads and MICR reader and ejects the form out
the back of the scanner onto the Exit Tray.
If the second sensor does not activate, as in the case of a
inserted form being skewed, the user will need to realign the
form with the right side of the scanner Entrance Tray before
feeding the form.
Andere Handbücher für 6100 Series
1
Inhaltsverzeichnis
Andere Pertech Scanner Handbücher