Profibus VEGASON 62 Bedienungsanleitung

Operating Instructions
Ultrasonic sensor for continuous level
measurement
VEGASON 62
Probus PA
Document ID: 28785

2
Contents
VEGASON 62 • Probus PA
28785-EN-150603
Contents
1 About this document
1.1 Function ........................................................................................................................... 4
1.2 Target group ..................................................................................................................... 4
1.3 Symbols used................................................................................................................... 4
2 For your safety
2.1 Authorised personnel ....................................................................................................... 5
2.2 Appropriate use................................................................................................................ 5
2.3 Warning about incorrect use............................................................................................. 5
2.4 General safety instructions............................................................................................... 5
2.5 Safety label on the instrument .......................................................................................... 6
2.6 CE conformity................................................................................................................... 6
2.7 Fulllment of NAMUR recommendations ......................................................................... 6
2.8 Environmental instructions ............................................................................................... 6
3 Product description
3.1 Conguration.................................................................................................................... 7
3.2 Principle of operation........................................................................................................ 8
3.3 Packaging, transport and storage..................................................................................... 9
3.4 Accessories and replacement parts ................................................................................. 9
4 Mounting
4.1 General instructions ....................................................................................................... 11
4.2 Mounting instructions ..................................................................................................... 12
5 Connecting to power supply
5.1 Preparing the connection ............................................................................................... 20
5.2 Connection procedure.................................................................................................... 21
5.3 Wiring plan, single chamber housing.............................................................................. 22
5.4 Wiring plan, double chamber housing ............................................................................ 23
5.5 Wiring plan - version IP 66/IP 68, 1 bar........................................................................... 25
5.6 Switch-on phase............................................................................................................. 26
6 Set up with the display and adjustment module PLICSCOM
6.1 Insert display and adjustment module............................................................................ 27
6.2 Adjustment system......................................................................................................... 28
6.3 Setup steps .................................................................................................................... 29
6.4 Menu schematic............................................................................................................. 39
6.9 Saving the parameter adjustment data........................................................................... 41
7 Set up with PACTware and other adjustment programs
7.1 Connect the PC via VEGACONNECT ............................................................................ 42
7.2 Parameter adjustment with PACTware............................................................................ 43
7.3 Parameter adjustment with PDM.................................................................................... 44
7.4 Saving the parameter adjustment data........................................................................... 44
8 Maintenanceandfaultrectication
8.1 Maintenance .................................................................................................................. 45
8.2 Rectify faults................................................................................................................... 45
8.3 Exchanging the electronics module................................................................................ 46
8.4 Software update ............................................................................................................. 47
8.5 How to proceed if a repair is necessary.......................................................................... 47

3
Contents
VEGASON 62 • Probus PA
28785-EN-150603
9 Dismount
9.1 Dismounting steps.......................................................................................................... 49
9.2 Disposal ......................................................................................................................... 49
10 Supplement
10.1 Technical data ................................................................................................................ 50
10.2 Probus PA..................................................................................................................... 54
10.3 Dimensions .................................................................................................................... 58
Safety instructions for Ex areas
Take note of the Ex specic safety instructions for Ex applications.
These instructions are attached as documents to each instrument
with Ex approval and are part of the operating instructions manual.
Editing status: 2015-05-21

4
1 About this document
VEGASON 62 • Probus PA
28785-EN-150603
1 About this document
1.1 Function
This operating instructions manual provides all the information you
need for mounting, connection and setup as well as important instruc-
tions for maintenance and fault rectication. Please read this informa-
tion before putting the instrument into operation and keep this manual
accessible in the immediate vicinity of the device.
1.2 Target group
This operating instructions manual is directed to trained specialist
personnel. The contents of this manual should be made available to
these personnel and put into practice by them.
1.3 Symbols used
Information, tip, note
This symbol indicates helpful additional information.
Caution: If this warning is ignored, faults or malfunctions can result.
Warning: If this warning is ignored, injury to persons and/or serious
damage to the instrument can result.
Danger: If this warning is ignored, serious injury to persons and/or
destruction of the instrument can result.
Ex applications
This symbol indicates special instructions for Ex applications.
SIL applications
This symbol indicates instructions for functional safety which must be
taken into account particularly for safety-relevant applications.
• List
The dot set in front indicates a list with no implied sequence.
→ Action
This arrow indicates a single action.
1 Sequence of actions
Numbers set in front indicate successive steps in a procedure.
Battery disposal
This symbol indicates special information about the disposal of bat-
teries and accumulators.

5
2 For your safety
VEGASON 62 • Probus PA
28785-EN-150603
2 For your safety
2.1 Authorised personnel
All operations described in this operating instructions manual must
be carried out only by trained specialist personnel authorised by the
plant operator.
During work on and with the device the required personal protective
equipment must always be worn.
2.2 Appropriate use
VEGASON 62 is a sensor for continuous level measurement.
You can nd detailed information about the area of application in
chapter "Product description".
Operational reliability is ensured only if the instrument is properly
used according to the specications in the operating instructions
manual as well as possible supplementary instructions.
For safety and warranty reasons, any invasive work on the device
beyond that described in the operating instructions manual may be
carried out only by personnel authorised by the manufacturer. Arbi-
trary conversions or modications are explicitly forbidden.
2.3 Warning about incorrect use
Inappropriate or incorrect use of the instrument can give rise to
application-specic hazards, e.g. vessel overll or damage to system
components through incorrect mounting or adjustment.
2.4 General safety instructions
This is a state-of-the-art instrument complying with all prevailing
regulations and guidelines. The instrument must only be operated in a
technically awless and reliable condition. The operator is responsible
for the trouble-free operation of the instrument.
During the entire duration of use, the user is obliged to determine the
compliance of the necessary occupational safety measures with the
current valid rules and regulations and also take note of new regula-
tions.
The safety instructions in this operating instructions manual, the na-
tional installation standards as well as the valid safety regulations and
accident prevention rules must be observed by the user.
For safety and warranty reasons, any invasive work on the device
beyond that described in the operating instructions manual may be
carried out only by personnel authorised by the manufacturer. Arbi-
trary conversions or modications are explicitly forbidden.
The safety approval markings and safety tips on the device must also
be observed.

6
2 For your safety
VEGASON 62 • Probus PA
28785-EN-150603
2.5 Safety label on the instrument
The safety approval markings and safety tips on the device must be
observed.
2.6 CE conformity
The device fullls the legal requirements of the applicable EC guide-
lines. By axing the CE marking, we conrm successful testing of the
product.
You can nd the CE Certicate of Conformity in the download section
of our homepage.
2.7 FulllmentofNAMURrecommendations
NAMUR is the automation technology user association in the process
industry in Germany. The published NAMUR recommendations are
accepted as the standard in eld instrumentation.
The device fullls the requirements of the following NAMUR recom-
mendations:
• NE 21 – Electromagnetic compatibility of equipment
• NE 43 – Signal level for malfunction information from measuring
transducers
• NE 53 – Compatibility of eld devices and display/adjustment
components
For further information see www.namur.de.
2.8 Environmental instructions
Protection of the environment is one of our most important duties.
That is why we have introduced an environment management system
with the goal of continuously improving company environmental pro-
tection. The environment management system is certied according
to DIN EN ISO 14001.
Please help us fulll this obligation by observing the environmental
instructions in this manual:
• Chapter "Packaging, transport and storage"
• Chapter "Disposal"

7
3 Product description
VEGASON 62 • Probus PA
28785-EN-150603
3 Product description
3.1 Conguration
The scope of delivery encompasses:
• Ultrasonic sensor
• Documentation
– Quick setup guide VEGASON 62
– Instructions for optional instrument features
– if necessary, further certicates
• DVD "Software", included therein
– PACTware/DTM Collection
– Driver software
Information:
In this operating instructions manual, the optional instrument features
are described. The respective scope of delivery results from the order
specication.
The VEGASON 62 consists of the components:
• Process tting with transducer
• Housing with electronics, optionally available with plug connector
• Housing cover, optionally available with display and adjustment
module PLICSCOM
The components are available in dierent versions.
1
2
3
Fig. 1: VEGASON 62 - threaded version with plastic housing
1 Housing cover with integrated PLICSCOM (optional)
2 Housing with electronics
3 Processttingwithtransducer
The type label contains the most important data for identication and
use of the instrument:
• Instrument type
Scope of delivery
Constituent parts
Type label

8
3 Product description
VEGASON 62 • Probus PA
28785-EN-150603
• Article and serial number device
• Article numbers, documentation
• Technical data: For example approvals, process temperature,
process tting/material, signal output, power supply, protection
• SIL identication (with SIL rating ex works)
With the serial number, you can access the delivery data of the instru-
ment via www.vega.com, "VEGA Tools" and "serial number search".
You can nd the serial number on the inside of the instrument as well
as on the type label on the outside.
This operating instructions manual applies to the following instrument
versions:
• Hardware version < 2.0.0
• Software version ≤ 3.8
3.2 Principle of operation
VEGASON 62 is an ultrasonic sensor for continuous level measure-
ment. It is suitable for liquids and solids in virtually all industries,
particularly in the water and waste water industry.
The transducer of the ultrasonic sensor transmits short ultrasonic
pulses to the measured product. These pulses are reected by
product surface and received back by the transducer as echoes.
The running time of the ultrasonic pulses from emission to reception
is proportional to the distance and hence the level. The determined
level is converted into an appropriate output signal and outputted as
measured value.
Power supply via the Probus DP/PA segment coupler or VEGALOG
571 EP cards. A two-wire cable according to Probus specication
serves as carrier of both power and digital data transmission for
multiple sensors. The instrument prole of VEGASON 62 corresponds
to prole specication version 3.0.
The backlight of the display and adjustment module is powered by the
sensor. Prerequisite is a certain level of operating voltage.
The data for power supply are specied in chapter "Technical data".
The optional heating requires its own operating voltage. You can nd
details in the supplementary instructions manual "Heating for display
and adjustment module".
This function is generally not available for approved instruments.
The GSD (instrument master les) and bitmap les necessary for
planning your Probus-DP-(PA) communication network are available
from the download section on the VEGA homepage www.vega.com
under "Services-Downloads-Software-Probus". There you can
also nd the appropriate certicates. In a PDM environment, an EDD
(Electronic Device Description) is also required to enable the full
range of sensor functions (also available as a download).A CD with
the appropriate les can be ordered via e-mail under info@de.vega.
Scope of this operating
instructions manual
Application area
Functional principle
Power supply and bus
communication
GSD/EDD

9
3 Product description
VEGASON 62 • Probus PA
28785-EN-150603
com or by phone from one of the VEGA agencies under the order
number "DRIVER.S".
3.3 Packaging, transport and storage
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test
based on ISO 4180.
The packaging of standard instruments consists of environment-
friendly, recyclable cardboard. For special versions, PE foam or PE
foil is also used. Dispose of the packaging material via specialised
recycling companies.
Transport must be carried out in due consideration of the notes on the
transport packaging. Nonobservance of these instructions can cause
damage to the device.
The delivery must be checked for completeness and possible transit
damage immediately at receipt. Ascertained transit damage or con-
cealed defects must be appropriately dealt with.
Up to the time of installation, the packages must be left closed and
stored according to the orientation and storage markings on the
outside.
Unless otherwise indicated, the packages must be stored only under
the following conditions:
• Not in the open
• Dry and dust free
• Not exposed to corrosive media
• Protected against solar radiation
• Avoiding mechanical shock and vibration
• Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
• Relative humidity 20 … 85 %
3.4 Accessories and replacement parts
The display and adjustment module PLICSCOM is used for measured
value indication, adjustment and diagnosis. It can be inserted into the
sensor and removed at any time.
You can nd further information in the operating instructions "Display
and adjustment module PLICSCOM" (Document-ID 27835).
The interface adapter VEGACONNECT enables the connection of
communication-capable instruments to the USB interface of a PC. For
parameter adjustment of these instruments, an adjustment software
such as PACTware with VEGA-DTM is required.
You can nd further information in the operating instructions "Interface
adapter VEGACONNECT" (Document-ID 32628).
Packaging
T
ransport
Transport inspection
Storage
Storage and transport
temperature
PLICSCOM
VEGACONNECT

10
3 Product description
VEGASON 62 • Probus PA
28785-EN-150603
The VEGADIS 81 is an external display and adjustment unit for VEGA
plics®sensors.
For sensors with double chamber housing the interface adapter
"DISADAPT" is also required for VEGADIS 81.
You can nd further information in the operating instructions "VE-
GADIS 81" (Document-ID 43814).
The protective cover protects the sensor housing against soiling and
intense heat from solar radiation.
You will nd additional information in the supplementary instructions
manual "Protective cover" (Document-ID 34296).
Flanges are available in dierent versions according to the following
standards: DIN 2501, EN 1092-1, ANSI B 16.5, JIS B 2210-1984,
GOST 12821-80.
You can nd additional information in the supplementary instructions
manual "Flanges according to DIN-EN-ASME-JIS" (Document-ID
31088).
Electronics module "VEGASON series 60" is a replacement part for
ultrasonic sensors of VEGASON series 60. A dierent version is avail-
able for each type of signal output.
You can nd further information in the operating instructions "Elec-
tronics module VEGASON series 60" (Document-ID 30206).
VEGADIS 81
Protective cap
Flanges
Electronics module
Inhaltsverzeichnis
Andere Profibus Zubehör Handbücher